AALBORG GFC17A-VAL6-A0-3NC-01-SS Mass Flow Controller, 0 to 10 ml/min N2, 1/4"

Model: GFC17A-VAL6-A0-3NC-01-SS | Order No: GFCS-010378

AALBORG GFC17A-VAL6-A0-3NC-01-SS Mass Flow Controller, 0 to 10 ml/min N2, 1/4"

Model: GFC17A-VAL6-A0-3NC-01-SS | Order No: GFCS-010378

Mass flow controllers designed to indicate and control flow rates of gases. Advanced straight tube sensor combined with flow passage elements constructed of aluminum and brass for non-corrosive gases. Features a Max Pressure Differential of 50 psi (3.4 bar).

Mass flow controllers designed to indicate and control flow rates of gases. Advanced straight tube sensor combined with flow passage elements constructed of aluminum and brass for non-corrosive gases. Features a Max Pressure Differential of 50 psi (3.4 bar).

Your Price $1412.00 USD
Availability 2 to 3 Weeks
Quantity

AALBORG GFC17A-VAL6-A0-3NC-01-SS Offers

Incorporated with an advanced U-shaped tube sensor, this controller is constructed of aluminum and brass for non-corrosive gases or 316 stainless steel for corrosive applications. In addition, this controller has a built-in electromagnetic valve that allows the flow to be set to any flow rate within the range.

Features

  • Rigid metallic construction
  • Maximum pressure of 1000 psig (70 bars)
  • Leak integrity 1 x 10-9 smL/second of helium
  • NIST traceable certification
  • Built-in tiltable LCD readout
  • Local or remote setpoint control
  • 0 to 5 V DC and 4 to 20 mA signals
  • Circuit protection

Principles of operation

Metered gases are divided into two laminar flow paths, one through the primary flow conduit, and the other through a capillary sensor tube. Both flow conduits are designed to ensure laminar flows and therefore the ratio of their flow rates is constant.

Two precision temperature sensing windings on the sensor tube are heated, and when flow takes place, gas carries heat from the upstream to the downstream windings. The resultant temperature differential is proportional to the change in resistance of the sensor windings.

A wheatstone bridge design is used to monitor the temperature dependent resistance gradient on the sensor windings which is linearly proportional to the instantaneous rate of flow.

Output signals of 0 to 5 V DC and 4 to 20 mA are generated indicating mass molecular based flow rates of the metered gas. The combined gas streams flow through a proportionating electromagnetic valve with an appropriately selected orifice. The closed loop control circuit continuously monitors the mass flow output and maintains it at the set flow rate.

Flow rates are unaffected by temperature and pressure variations within stated limitations.

Applications

  • Indicate and control flow rates of gases

AALBORG GFC17A-VAL6-A0-3NC-01-SS Specifications

Accuracy ±1% of full scale
Calibration Performed at standard conditions [14.7 psia (101.4 kPa) and 70°F (21.1°C)] unless otherwise requested
Repeatability ±0.5% of full scale
Response Time 300 ms time constant
Approximately 1 second to within ±2% of set flow rate for 25% to 100% of full scale flow
Coefficient Temperature 0.15% of full scale/°C
Pressure: 0.01% of full scale/psi (0.07 bar)
Gas Pressure Optimum: 25 psig (1.73 bar)
Maximum: 1000 psig (70 bar)
Turn Down Ratio 40:1
Maximum Pressure Difference 50 psi (3.4 bar)
Gas and Ambient Temperature 32 to 122°F (0 to 50°C)
Leak Integrity 1 x 10 to 9 smL/second of helium maximum to the outside environment
Materials Fluid Contact Anodized aluminum, 316 stainless steel, brass & Viton O to rings 
Attitude Sensitivity No greater than ±15° rotation from horizontal to vertical
Signals Output:
Linear 0 to 5 V DC (1000 Ω minimum load impedance)
4 to 20 mA (0 to 500 Ω loop resistance)
Maximum noise ±20 mV

Command Signals:
Analog 0 to 5 V DC
4 to 20 mA for remote set point mode
NPN compatible purge/valve off
Connections ¼" (0.635 cm) compression fittings Tube O diameter 
Transducer Input Power Universal +12 V DC to 26 V DC, 650 mA maximum
Circuit Protection Circuit boards have built-in polarity reversal protection
Resettable fuses provide power input protection
Display 3½ digit LCD
0.5" (1.27 cm) high characters
CE Compliant EN 55011 class 1, class B; EN50082-1
Dimensions 5.72 x 6.29 x 1" (14.53 x 15.98 x 2.54 cm)
Click here for complete specifications on the AALBORG GFC17A-VAL6-A0-3NC-01-SS

What's included with the AALBORG GFC17A-VAL6-A0-3NC-01-SS

  • AALBORG GFC17A-VAL6-A0-3NC-01-SS Mass Flow Controller, 0 to 10 ml/min N2, 1/4"

Click on a category to view a selection of compatible accessories with the AALBORG GFC17A-VAL6-A0-3NC-01-SS Mass Flow Controller, 0 to 10 ml/min N2, 1/4".

AALBORG PS-GFC-110NA-2 Power Supply for AALBORG Mass Flow Controllers PS-GFC-110NA-2
This US plug is has an 120V AC input and is for use with the AALBORG Aluminum Flow Controllers.




Ask a question about AALBORG GFC17A-VAL6-A0-3NC-01-SS Mass Flow Controller, 0 to 10 ml/min N2, 1/4"

Customer Reviews for the AALBORG GFC17A-VAL6-A0-3NC-01-SS

AALBORG GFC17A-VAL6-A0-3NC-01-SS Offers

Incorporated with an advanced U-shaped tube sensor, this controller is constructed of aluminum and brass for non-corrosive gases or 316 stainless steel for corrosive applications. In addition, this controller has a built-in electromagnetic valve that allows the flow to be set to any flow rate within the range.

Features

  • Rigid metallic construction
  • Maximum pressure of 1000 psig (70 bars)
  • Leak integrity 1 x 10-9 smL/second of helium
  • NIST traceable certification
  • Built-in tiltable LCD readout
  • Local or remote setpoint control
  • 0 to 5 V DC and 4 to 20 mA signals
  • Circuit protection

Principles of operation

Metered gases are divided into two laminar flow paths, one through the primary flow conduit, and the other through a capillary sensor tube. Both flow conduits are designed to ensure laminar flows and therefore the ratio of their flow rates is constant.

Two precision temperature sensing windings on the sensor tube are heated, and when flow takes place, gas carries heat from the upstream to the downstream windings. The resultant temperature differential is proportional to the change in resistance of the sensor windings.

A wheatstone bridge design is used to monitor the temperature dependent resistance gradient on the sensor windings which is linearly proportional to the instantaneous rate of flow.

Output signals of 0 to 5 V DC and 4 to 20 mA are generated indicating mass molecular based flow rates of the metered gas. The combined gas streams flow through a proportionating electromagnetic valve with an appropriately selected orifice. The closed loop control circuit continuously monitors the mass flow output and maintains it at the set flow rate.

Flow rates are unaffected by temperature and pressure variations within stated limitations.

Applications

  • Indicate and control flow rates of gases

AALBORG GFC17A-VAL6-A0-3NC-01-SS Specifications

Accuracy ±1% of full scale
Calibration Performed at standard conditions [14.7 psia (101.4 kPa) and 70°F (21.1°C)] unless otherwise requested
Repeatability ±0.5% of full scale
Response Time 300 ms time constant
Approximately 1 second to within ±2% of set flow rate for 25% to 100% of full scale flow
Coefficient Temperature 0.15% of full scale/°C
Pressure: 0.01% of full scale/psi (0.07 bar)
Gas Pressure Optimum: 25 psig (1.73 bar)
Maximum: 1000 psig (70 bar)
Turn Down Ratio 40:1
Maximum Pressure Difference 50 psi (3.4 bar)
Gas and Ambient Temperature 32 to 122°F (0 to 50°C)
Leak Integrity 1 x 10 to 9 smL/second of helium maximum to the outside environment
Materials Fluid Contact Anodized aluminum, 316 stainless steel, brass & Viton O to rings 
Attitude Sensitivity No greater than ±15° rotation from horizontal to vertical
Signals Output:
Linear 0 to 5 V DC (1000 Ω minimum load impedance)
4 to 20 mA (0 to 500 Ω loop resistance)
Maximum noise ±20 mV

Command Signals:
Analog 0 to 5 V DC
4 to 20 mA for remote set point mode
NPN compatible purge/valve off
Connections ¼" (0.635 cm) compression fittings Tube O diameter 
Transducer Input Power Universal +12 V DC to 26 V DC, 650 mA maximum
Circuit Protection Circuit boards have built-in polarity reversal protection
Resettable fuses provide power input protection
Display 3½ digit LCD
0.5" (1.27 cm) high characters
CE Compliant EN 55011 class 1, class B; EN50082-1
Dimensions 5.72 x 6.29 x 1" (14.53 x 15.98 x 2.54 cm)
Click here for complete specifications on the AALBORG GFC17A-VAL6-A0-3NC-01-SS

What's included with the AALBORG GFC17A-VAL6-A0-3NC-01-SS

  • AALBORG GFC17A-VAL6-A0-3NC-01-SS Mass Flow Controller, 0 to 10 ml/min N2, 1/4"

Click on a category to view a selection of compatible accessories with the AALBORG GFC17A-VAL6-A0-3NC-01-SS Mass Flow Controller, 0 to 10 ml/min N2, 1/4".

AALBORG PS-GFC-110NA-2 Power Supply for AALBORG Mass Flow Controllers PS-GFC-110NA-2
This US plug is has an 120V AC input and is for use with the AALBORG Aluminum Flow Controllers.




Ask a question about AALBORG GFC17A-VAL6-A0-3NC-01-SS Mass Flow Controller, 0 to 10 ml/min N2, 1/4"

Customer Reviews for the AALBORG GFC17A-VAL6-A0-3NC-01-SS

More AALBORG Products

Calibration Lab