AEMC L101 AC Current Logger

Model: L101 | Order No: 2126.02 | UPC: 685338140330

Perform many recording tasks with this lightweight and compact one-channel logger that stores up to 240,000 measurements in non-volatile memory and has five LED indicators. In addition, this logger works with 64 samples per cycle and includes DataView software for data storage, real-time display, analysis, and report generation.

Perform many recording tasks with this lightweight and compact one-channel logger that stores up to 240,000 measurements in non-volatile memory and has five LED indicators. In addition, this logger works with 64 samples per cycle and includes DataView software for data storage, real-time display, analysis, and report generation.

Sale Price $369.55 USD
Regular Price $389.00 USD
Availability 1 to 2 Weeks
Quantity

Traceable In-House Calibration Certificate for your L101 AC Current Logger

Traceable In-House Calibration Certificate for your L101 AC Current Logger

The Simple Logger® II Model L101 is a one channel recording device powered by an alkaline battery pack. Line tracking is performed such that 64 samples over one line cycle are taken. Frequency tracking is performed over the range of ±2Hz around the nominal line frequency (50 or 60Hz). Harmonic measurements are calculated from these 64 samples (Harmonics are only available from the Simple Logger® II Control Panel within the DataView® software).

The Simple Logger® II records TRMS at a rate of up to eight times per second. The measurement process is performed no more than eight times per second. TRMS calculations are performed on a single line cycle. This means that the input(s) are ignored between measurement intervals.The main advantage of the logger is its ability to perform a variety of recording tasks with easy and intuitive setup from a computer using DataView® software.

Analog information on the input is sampled and converted to a digital signal. This digital signal is processed and stored along with scale and time information. An optically isolated Universal Serial Bus (USB) port provides for the transfer of data from the instrument's internal memory to the computer for analysis.


Applications

  • Load profiling
  • Fault current detection
  • Intermittent problem detection
  • Demand recording
  • Neutral current monitoring
  • Harmonic current recording using DataView® software
  • Metering CT resizing

Key Features

  • Compatible standard current probes with voltage output and BNC connection
  • 64 samples per cycle
  • Programmable storage rates from 8 every second to 1 every day
  • 3 user selectable storage modes
  • Stores up to 240,000 measurements in non-volatile memory
  • Powered by standard Alkaline batteries
  • Lightweight, compact, fits anywhere
  • 5 LED indicators quickly and clearly display Logger status
  • Includes DataView® software for data storage, real-time waveform display, analysis and report generation
  • Isolated USB communication
  • 50V Cat III

Specifications

Simple Logger II Model L101
Electrical
Channels One
Input Connection BNC
Measurement Range 0 to 1V
Resolution 0.1mV
Accuracy (50/60Hz) 0 to 10mV: unspecified 10 to 50mV: ±(0.5% of Reading + 1mV) 50 to 1000mV: ±(0.5% of Reading + 0.5mV)
Sample Rate 64 samples/cycle
Storage Rate Programmable from 125ms to 1 day
Storage Modes Start/Stop, FIFO and Extended Recording Mode (XRM™)
Recording Length 15 minutes to 8 weeks, programmable using DataView
Memory 240,000 measurements (512KB) - The recorded data is stored in non-volatile memory and will be retained even if the battery is low or removed.
Communication USB 2.0 optically isolated
Power Source 2 x 1.5V AA-cell alkaline batteries
Battery Life 100 hours to >45 days (dependent on sample rate and recording length)
Mechanical
Dimensions 5.38 x 2.75 x 1.28" (136 x 70 x 32mm)
Max Conductor Size Current probe dependent
Weight (with battery) 6.4 oz (181 grams)
Case UL94-V0
Vibration IEC 68-2-6 (1.5mm, 10 to 55Hz)
Shock IEC 68-2-27 (30G)
Drop IEC 68-2-32 (1m)
Click here for complete specifications on the AEMC Instruments L101

What's included with the AEMC Instruments L101

  • AEMC L101 AC Current Logger

Ask a question about AEMC L101 AC Current Logger

Customer Reviews for the AEMC Instruments L101

The Simple Logger® II Model L101 is a one channel recording device powered by an alkaline battery pack. Line tracking is performed such that 64 samples over one line cycle are taken. Frequency tracking is performed over the range of ±2Hz around the nominal line frequency (50 or 60Hz). Harmonic measurements are calculated from these 64 samples (Harmonics are only available from the Simple Logger® II Control Panel within the DataView® software).

The Simple Logger® II records TRMS at a rate of up to eight times per second. The measurement process is performed no more than eight times per second. TRMS calculations are performed on a single line cycle. This means that the input(s) are ignored between measurement intervals.The main advantage of the logger is its ability to perform a variety of recording tasks with easy and intuitive setup from a computer using DataView® software.

Analog information on the input is sampled and converted to a digital signal. This digital signal is processed and stored along with scale and time information. An optically isolated Universal Serial Bus (USB) port provides for the transfer of data from the instrument's internal memory to the computer for analysis.


Applications

  • Load profiling
  • Fault current detection
  • Intermittent problem detection
  • Demand recording
  • Neutral current monitoring
  • Harmonic current recording using DataView® software
  • Metering CT resizing

Key Features

  • Compatible standard current probes with voltage output and BNC connection
  • 64 samples per cycle
  • Programmable storage rates from 8 every second to 1 every day
  • 3 user selectable storage modes
  • Stores up to 240,000 measurements in non-volatile memory
  • Powered by standard Alkaline batteries
  • Lightweight, compact, fits anywhere
  • 5 LED indicators quickly and clearly display Logger status
  • Includes DataView® software for data storage, real-time waveform display, analysis and report generation
  • Isolated USB communication
  • 50V Cat III

Specifications

Simple Logger II Model L101
Electrical
Channels One
Input Connection BNC
Measurement Range 0 to 1V
Resolution 0.1mV
Accuracy (50/60Hz) 0 to 10mV: unspecified 10 to 50mV: ±(0.5% of Reading + 1mV) 50 to 1000mV: ±(0.5% of Reading + 0.5mV)
Sample Rate 64 samples/cycle
Storage Rate Programmable from 125ms to 1 day
Storage Modes Start/Stop, FIFO and Extended Recording Mode (XRM™)
Recording Length 15 minutes to 8 weeks, programmable using DataView
Memory 240,000 measurements (512KB) - The recorded data is stored in non-volatile memory and will be retained even if the battery is low or removed.
Communication USB 2.0 optically isolated
Power Source 2 x 1.5V AA-cell alkaline batteries
Battery Life 100 hours to >45 days (dependent on sample rate and recording length)
Mechanical
Dimensions 5.38 x 2.75 x 1.28" (136 x 70 x 32mm)
Max Conductor Size Current probe dependent
Weight (with battery) 6.4 oz (181 grams)
Case UL94-V0
Vibration IEC 68-2-6 (1.5mm, 10 to 55Hz)
Shock IEC 68-2-27 (30G)
Drop IEC 68-2-32 (1m)
Click here for complete specifications on the AEMC Instruments L101