Two input channel logger capable of recording True RMS current (compatible with AC current probes with voltage outputs) and True RMS voltage to 600V. Stores up to 240,000 measurements.
Two input channel logger capable of recording True RMS current (compatible with AC current probes with voltage outputs) and True RMS voltage to 600V. Stores up to 240,000 measurements.
The AEMC L562 Simple Logger II is a two channel Volt/Amp data logger. The Extended Recording Mode (XRM) and delayed start time are just two of the many application friendly features.
The Simple Logger® II records TRMS at a rate of up to eight times per second. The measurement process is performed no more than eight times per second. TRMS calculations are performed on a single line cycle. This means that the input(s) are ignored between measurement intervals.
The main advantage of the logger is its ability to perform a variety of recording tasks with easy and intuitive setup from a computer using DataView® software.
Analog information on the input is sampled and converted to a digital signal. This digital signal is processed and stored along with scale and time information. An optically isolated Universal Serial Bus (USB) port provides for the transfer of data from the instruments internal memory to the computer for analysis.
Probes are not included and must be purchased separately.
Features
Applications
Current Channel | |
Input Connection | BNC |
Input Range | 0 to 1V AC (for use with current probes with a voltage output) |
Resolution | 0.1mV |
Accuracy (50/60Hz) | 0 to 10mV unspecified 10 to 50mV: ±(0.5% of Reading + 1mV) 50 to 1000mV: ±(0.5% of Reading + 0.5mV) |
Input Impedance | 800kΩ |
Maximum Input Voltage | 5Vrms or ± 7.07V peak |
Voltage Channel | |
Input Connection | Two recessed banana jacks |
Input Range | 0 to 600V AC |
Resolution | 0.1V |
Accuracy (50/60Hz) | 0 to 5V unspecified 5 to 50V: ±(0.5% of Reading + 1V) 50 to 600V: ±(0.5% of Reading + 0.5V) |
Input Impedance | 40MΩ |
Maximum Input Voltage | 1.2 x 600V |
Electrical | |
Sample Rate | 64 samples/cycle |
Storage Rate | Programmable from 8 every second to 1 every day |
Storage Modes | Start/Stop, FIFO, Extended Recording Mode (XRM™) and Alarm |
Recording Length | 15 minutes to 8 weeks, programmable using DataView® |
Memory | 240,000 measurement (512KB) Data is stored in non-volatile memory and retained if the battery is low or removed |
Communication | USB 2.0 optically isolated |
Power Source | 2 x 1.5V AA-cell Alkaline batteries (included) |
Battery Life | 100 hours to > 45 days (dependent on sample rate and recording length) |
Click on a category to view a selection of compatible accessories with the AEMC L562 Simple Logger II AC Voltage/Current Data Logger, 600 V.
Current Channel | |
Input Connection | BNC |
Input Range | 0 to 1V AC (for use with current probes with a voltage output) |
Resolution | 0.1mV |
Accuracy (50/60Hz) | 0 to 10mV unspecified 10 to 50mV: ±(0.5% of Reading + 1mV) 50 to 1000mV: ±(0.5% of Reading + 0.5mV) |
Input Impedance | 800kΩ |
Maximum Input Voltage | 5Vrms or ± 7.07V peak |
Voltage Channel | |
Input Connection | Two recessed banana jacks |
Input Range | 0 to 600V AC |
Resolution | 0.1V |
Accuracy (50/60Hz) | 0 to 5V unspecified 5 to 50V: ±(0.5% of Reading + 1V) 50 to 600V: ±(0.5% of Reading + 0.5V) |
Input Impedance | 40MΩ |
Maximum Input Voltage | 1.2 x 600V |
Electrical | |
Sample Rate | 64 samples/cycle |
Storage Rate | Programmable from 8 every second to 1 every day |
Storage Modes | Start/Stop, FIFO, Extended Recording Mode (XRM™) and Alarm |
Recording Length | 15 minutes to 8 weeks, programmable using DataView® |
Memory | 240,000 measurement (512KB) Data is stored in non-volatile memory and retained if the battery is low or removed |
Communication | USB 2.0 optically isolated |
Power Source | 2 x 1.5V AA-cell Alkaline batteries (included) |
Battery Life | 100 hours to > 45 days (dependent on sample rate and recording length) |
Click on a category to view a selection of compatible accessories with the AEMC L562 Simple Logger II AC Voltage/Current Data Logger, 600 V.