AEMC L562 Simple Logger II AC Voltage/Current Data Logger, 600 V

Model: L562 | Order No: 2126.35 | UPC: 685338140408

AEMC L562 Simple Logger II AC Voltage/Current Data Logger, 600 V

Model: L562 | Order No: 2126.35 | UPC: 685338140408

Two input channel logger capable of recording True RMS current (compatible with AC current probes with voltage outputs) and True RMS voltage to 600V. Stores up to 240,000 measurements.

Two input channel logger capable of recording True RMS current (compatible with AC current probes with voltage outputs) and True RMS voltage to 600V. Stores up to 240,000 measurements.

Sale Price $465.50 USD
Regular Price $490.00 USD
Availability 1 to 2 Weeks
Quantity

Traceable In-House Calibration Certificate for your L562 Simple Logger II AC Voltage/Current Data Logger

Traceable In-House Calibration Certificate for your L562 Simple Logger II AC Voltage/Current Data Logger

AEMC L562 Offers

The AEMC L562 Simple Logger II is a two channel Volt/Amp data logger. The Extended Recording Mode (XRM) and delayed start time are just two of the many application friendly features.

The Simple Logger® II records TRMS at a rate of up to eight times per second. The measurement process is performed no more than eight times per second. TRMS calculations are performed on a single line cycle. This means that the input(s) are ignored between measurement intervals.

The main advantage of the logger is its ability to perform a variety of recording tasks with easy and intuitive setup from a computer using DataView® software.

Analog information on the input is sampled and converted to a digital signal. This digital signal is processed and stored along with scale and time information. An optically isolated Universal Serial Bus (USB) port provides for the transfer of data from the instrument’s internal memory to the computer for analysis.

Probes are not included and must be purchased separately.

Features

  • 2 input channels
  • Voltage: 0 to 600VAC TRMS
  • Current: compatible with voltage output AC current probes with voltage outputs
  • 64 samples per cycle
  • Records Arms, Vrms & VA (VA displays in DataView® software)
  • 4 user selectable storage modes
  • Programmable storage rates from 8 every second to 1 every day
  • Stores up to 240,000 measurements in non-volatile memory
  • Powered by standard Alkaline batteries
  • Lightweight, compact, fits anywhere
  • 5 LED indicators quickly and clearly display logger status
  • Includes FREE DataView® software for data storage, real-time display, analysis and report generation
  • EN 61010-1; 300V CAT IV; 600V CAT III with a safety rated current probe attached
  • Isolated USB 2.0 communication cable included

Applications

  • Single phase power monitoring
  • Residential, commercial, industrial troubleshooting
  • Find sags and surges
  • Track energy usage

AEMC L562 Specifications

Current Channel
Input Connection BNC
Input Range 0 to 1V AC (for use with current probes with a voltage output)
Resolution 0.1mV
Accuracy (50/60Hz) 0 to 10mV unspecified
10 to 50mV: ±(0.5% of Reading + 1mV)
50 to 1000mV: ±(0.5% of Reading + 0.5mV)
Input Impedance 800kΩ
Maximum Input Voltage 5Vrms or ± 7.07V peak
Voltage Channel
Input Connection Two recessed banana jacks
Input Range 0 to 600V AC
Resolution 0.1V
Accuracy (50/60Hz) 0 to 5V unspecified
5 to 50V: ±(0.5% of Reading + 1V)
50 to 600V: ±(0.5% of Reading + 0.5V)
Input Impedance 40MΩ
Maximum Input Voltage 1.2 x 600V
Electrical  
Sample Rate 64 samples/cycle
Storage Rate Programmable from 8 every second to 1 every day
Storage Modes Start/Stop, FIFO, Extended Recording Mode (XRM™) and Alarm
Recording Length 15 minutes to 8 weeks, programmable using DataView®
Memory 240,000 measurement (512KB)
Data is stored in non-volatile memory and retained if the battery is low or removed
Communication USB 2.0 optically isolated
Power Source 2 x 1.5V AA-cell Alkaline batteries (included)
Battery Life 100 hours to > 45 days (dependent on sample rate and recording length)
Click here for complete specifications on the AEMC Instruments L562

What's included with the AEMC L562

  • L562 Simple Logger II True RMS Datalogger
  • USB cable
  • DataView® software
  • 2 x 1.5V AA alkaline batteries
  • Set of leads
  • Set of alligator clips
  • Manual

Click on a category to view a selection of compatible accessories with the AEMC L562 Simple Logger II AC Voltage/Current Data Logger, 600 V.

AEMC 1000-24-1-1 AmpFlex Current Transformer, 1mV/A, 1000A, 24" 1000-24-1-1
Lightweight and featuring a sensor length of 24", the AEMC 1000-24-1-1 AmpFlex Flexible Current Probe does not use a magnetic core like a standard transformer.




AEMC SR759 AC Current Probe, Lead, 1/10/100/1000A/1V SR759
This Current Probe is designed for use in utility and industrial environments. The unique ergonomic design allows it to easily clamp onto cables or small bus bars. It is assembled to the highest safety and performance standards including the CE Mark and is UL approved for Canada and United States.




AEMC SR752 AC Current Probe, Lead, 1mV/A, 1200A AC, 5ft SR752
This Current Probe is designed for use in utility and industrial environments. The unique ergonomic design allows it to easily clamp onto cables or small bus bars. It is assembled to the highest safety and performance standards including the CE Mark and is UL approved for Canada and United States.




AEMC SR661 AC Current Probe, 1/10/100mV/A, 2000A AC, 6.5ft SR661
This Current Probe is designed for use in utility and industrial environments. The unique ergonomic design allows it to easily clamp onto cables or small bus bars. It is assembled to the highest safety and performance standards including the CE Mark and is UL approved for Canada and United States.




AEMC MN375 AC Current Probe, 10 AAC MN375
Designed to meet the most stringent demands in industry and electrical contracting, and meets EN 61010, 600 V CAT III safety standards and is CE marked and UL approved. Features a 0.78" (20 mm) jaw opening and will accommodate conductors up to 250 kcmil, and the unique hooked jaw design facilitates clamping and hooking into conductors.




AEMC MN353 AC Current Probe, Lead, 10mV/A, 150A MN353
Designed to meet the most stringent demands in industry and electrical contracting, they also meet the latest safety and performance standards. Features a measurement range of 0.1 to 150A and a large jaw opening accommodates conductors up to 250kcmil.




AEMC MN261 AC Current Probe, BNC, 100mV/A, 24A, 10mV/A, 240A MN261
This small and compact Current Probe is designed to meet the most stringent demands in industry and electrical contracting. Model MN261 meets EN 61010, 600V, Cat. III safety standards and is CE Marked and UL approved in Canada and United States. Features a measurement range of 0.5 to 240A AC.




AEMC MN255 AC Current Probe, Lead, 100mV/A, 24A, 10mV/A, 240A MN255
This small and compact Current Probe is designed to meet the most stringent demands in industry and electrical contracting. Model MN255 meets EN 61010, 600V, Cat. III safety standards and is CE Marked and UL approved for Canada and United States. Features a measurement range of 0.5 to 240A AC.




AEMC JM861 AC Current Probe, BNC, 30A/300A/3000A JM861
Oscilloscope current probe for applications in industrial and power environments. Analyze, measure and accurately display distorted current waveforms and harmonics.




AEMC 6000-36-2-0.1 Flexible Current Probe, 600/6000A, 36" 6000-36-2-0.1
Flexible AC current probe composed of a flexible sensor and an electronic module. The flexible sensor permits measurements on conductors where standard clamp-on probes cannot be used.




AEMC 300-24-2-10 Flexible Current Probe, 30/300A, 24" 300-24-2-10
Flexible AC current probe composed of a flexible sensor and an electronic module. The flexible sensor permits measurements on conductors where standard clamp-on probes cannot be used.




AEMC 30000-24-2-0.1 Flexible Current Probe, 3000/30000A, 24" 30000-24-2-0.1
Flexible AC current probe composed of a flexible sensor and an electronic module. The flexible sensor permits measurements on conductors where standard clamp-on probes cannot be used.




AEMC 1000-36-2-1 AmpFlex Current Transformer, 10mV/1mV/A, 100/1000A, 36" 1000-36-2-1
Flexible AC current probe composed of a flexible sensor and an electronic module. The flexible sensor permits measurements on conductors where standard clamp-on probes cannot be used.




AEMC 1000-24-2-1 AmpFlex Current Transformer, 10mV/1mV/A, 100/1000A, 24" 1000-24-2-1
Flexible AC current probe composed of a flexible sensor and an electronic module. The flexible sensor permits measurements on conductors where standard clamp-on probes cannot be used.




Ask a question about AEMC L562 Simple Logger II AC Voltage/Current Data Logger, 600 V

Customer Reviews for the AEMC Instruments L562

AEMC L562 Offers

The AEMC L562 Simple Logger II is a two channel Volt/Amp data logger. The Extended Recording Mode (XRM) and delayed start time are just two of the many application friendly features.

The Simple Logger® II records TRMS at a rate of up to eight times per second. The measurement process is performed no more than eight times per second. TRMS calculations are performed on a single line cycle. This means that the input(s) are ignored between measurement intervals.

The main advantage of the logger is its ability to perform a variety of recording tasks with easy and intuitive setup from a computer using DataView® software.

Analog information on the input is sampled and converted to a digital signal. This digital signal is processed and stored along with scale and time information. An optically isolated Universal Serial Bus (USB) port provides for the transfer of data from the instrument’s internal memory to the computer for analysis.

Probes are not included and must be purchased separately.

Features

  • 2 input channels
  • Voltage: 0 to 600VAC TRMS
  • Current: compatible with voltage output AC current probes with voltage outputs
  • 64 samples per cycle
  • Records Arms, Vrms & VA (VA displays in DataView® software)
  • 4 user selectable storage modes
  • Programmable storage rates from 8 every second to 1 every day
  • Stores up to 240,000 measurements in non-volatile memory
  • Powered by standard Alkaline batteries
  • Lightweight, compact, fits anywhere
  • 5 LED indicators quickly and clearly display logger status
  • Includes FREE DataView® software for data storage, real-time display, analysis and report generation
  • EN 61010-1; 300V CAT IV; 600V CAT III with a safety rated current probe attached
  • Isolated USB 2.0 communication cable included

Applications

  • Single phase power monitoring
  • Residential, commercial, industrial troubleshooting
  • Find sags and surges
  • Track energy usage

AEMC L562 Specifications

Current Channel
Input Connection BNC
Input Range 0 to 1V AC (for use with current probes with a voltage output)
Resolution 0.1mV
Accuracy (50/60Hz) 0 to 10mV unspecified
10 to 50mV: ±(0.5% of Reading + 1mV)
50 to 1000mV: ±(0.5% of Reading + 0.5mV)
Input Impedance 800kΩ
Maximum Input Voltage 5Vrms or ± 7.07V peak
Voltage Channel
Input Connection Two recessed banana jacks
Input Range 0 to 600V AC
Resolution 0.1V
Accuracy (50/60Hz) 0 to 5V unspecified
5 to 50V: ±(0.5% of Reading + 1V)
50 to 600V: ±(0.5% of Reading + 0.5V)
Input Impedance 40MΩ
Maximum Input Voltage 1.2 x 600V
Electrical  
Sample Rate 64 samples/cycle
Storage Rate Programmable from 8 every second to 1 every day
Storage Modes Start/Stop, FIFO, Extended Recording Mode (XRM™) and Alarm
Recording Length 15 minutes to 8 weeks, programmable using DataView®
Memory 240,000 measurement (512KB)
Data is stored in non-volatile memory and retained if the battery is low or removed
Communication USB 2.0 optically isolated
Power Source 2 x 1.5V AA-cell Alkaline batteries (included)
Battery Life 100 hours to > 45 days (dependent on sample rate and recording length)
Click here for complete specifications on the AEMC Instruments L562

What's included with the AEMC L562

  • L562 Simple Logger II True RMS Datalogger
  • USB cable
  • DataView® software
  • 2 x 1.5V AA alkaline batteries
  • Set of leads
  • Set of alligator clips
  • Manual

Click on a category to view a selection of compatible accessories with the AEMC L562 Simple Logger II AC Voltage/Current Data Logger, 600 V.

AEMC 1000-24-1-1 AmpFlex Current Transformer, 1mV/A, 1000A, 24" 1000-24-1-1
Lightweight and featuring a sensor length of 24", the AEMC 1000-24-1-1 AmpFlex Flexible Current Probe does not use a magnetic core like a standard transformer.




AEMC SR759 AC Current Probe, Lead, 1/10/100/1000A/1V SR759
This Current Probe is designed for use in utility and industrial environments. The unique ergonomic design allows it to easily clamp onto cables or small bus bars. It is assembled to the highest safety and performance standards including the CE Mark and is UL approved for Canada and United States.




AEMC SR752 AC Current Probe, Lead, 1mV/A, 1200A AC, 5ft SR752
This Current Probe is designed for use in utility and industrial environments. The unique ergonomic design allows it to easily clamp onto cables or small bus bars. It is assembled to the highest safety and performance standards including the CE Mark and is UL approved for Canada and United States.




AEMC SR661 AC Current Probe, 1/10/100mV/A, 2000A AC, 6.5ft SR661
This Current Probe is designed for use in utility and industrial environments. The unique ergonomic design allows it to easily clamp onto cables or small bus bars. It is assembled to the highest safety and performance standards including the CE Mark and is UL approved for Canada and United States.




AEMC MN375 AC Current Probe, 10 AAC MN375
Designed to meet the most stringent demands in industry and electrical contracting, and meets EN 61010, 600 V CAT III safety standards and is CE marked and UL approved. Features a 0.78" (20 mm) jaw opening and will accommodate conductors up to 250 kcmil, and the unique hooked jaw design facilitates clamping and hooking into conductors.




AEMC MN353 AC Current Probe, Lead, 10mV/A, 150A MN353
Designed to meet the most stringent demands in industry and electrical contracting, they also meet the latest safety and performance standards. Features a measurement range of 0.1 to 150A and a large jaw opening accommodates conductors up to 250kcmil.




AEMC MN261 AC Current Probe, BNC, 100mV/A, 24A, 10mV/A, 240A MN261
This small and compact Current Probe is designed to meet the most stringent demands in industry and electrical contracting. Model MN261 meets EN 61010, 600V, Cat. III safety standards and is CE Marked and UL approved in Canada and United States. Features a measurement range of 0.5 to 240A AC.




AEMC MN255 AC Current Probe, Lead, 100mV/A, 24A, 10mV/A, 240A MN255
This small and compact Current Probe is designed to meet the most stringent demands in industry and electrical contracting. Model MN255 meets EN 61010, 600V, Cat. III safety standards and is CE Marked and UL approved for Canada and United States. Features a measurement range of 0.5 to 240A AC.




AEMC JM861 AC Current Probe, BNC, 30A/300A/3000A JM861
Oscilloscope current probe for applications in industrial and power environments. Analyze, measure and accurately display distorted current waveforms and harmonics.




AEMC 6000-36-2-0.1 Flexible Current Probe, 600/6000A, 36" 6000-36-2-0.1
Flexible AC current probe composed of a flexible sensor and an electronic module. The flexible sensor permits measurements on conductors where standard clamp-on probes cannot be used.




AEMC 300-24-2-10 Flexible Current Probe, 30/300A, 24" 300-24-2-10
Flexible AC current probe composed of a flexible sensor and an electronic module. The flexible sensor permits measurements on conductors where standard clamp-on probes cannot be used.




AEMC 30000-24-2-0.1 Flexible Current Probe, 3000/30000A, 24" 30000-24-2-0.1
Flexible AC current probe composed of a flexible sensor and an electronic module. The flexible sensor permits measurements on conductors where standard clamp-on probes cannot be used.




AEMC 1000-36-2-1 AmpFlex Current Transformer, 10mV/1mV/A, 100/1000A, 36" 1000-36-2-1
Flexible AC current probe composed of a flexible sensor and an electronic module. The flexible sensor permits measurements on conductors where standard clamp-on probes cannot be used.




AEMC 1000-24-2-1 AmpFlex Current Transformer, 10mV/1mV/A, 100/1000A, 24" 1000-24-2-1
Flexible AC current probe composed of a flexible sensor and an electronic module. The flexible sensor permits measurements on conductors where standard clamp-on probes cannot be used.




Ask a question about AEMC L562 Simple Logger II AC Voltage/Current Data Logger, 600 V

Customer Reviews for the AEMC Instruments L562

More AEMC Instruments Products

Calibration Lab