AMETEK Crystal HPC41 Pressure Calibrator with the AHX system A, single sensor, 0 to 300 psi

Model: HPC41-300PSI-AHX

AMETEK Crystal HPC41 Pressure Calibrator with the AHX system A, single sensor, 0 to 300 psi

Model: HPC41-300PSI-AHX

Work with advanced simplicity with this single sensor pressure calibrator that features a 0 to 300 psi range and the AHX system A with a 0 to 580 psi/40 bar pressure range. In addition, it's the world's first combined pressure and mA loop calibrator to be fully temperature compensated from -4 to 122°F (-20 to 50°C).

Work with advanced simplicity with this single sensor pressure calibrator that features a 0 to 300 psi range and the AHX system A with a 0 to 580 psi/40 bar pressure range. In addition, it's the world's first combined pressure and mA loop calibrator to be fully temperature compensated from -4 to 122°F (-20 to 50°C).

Sale Price $5350.52 USD
Regular Price $5432.00 USD
Availability 2 to 3 Weeks
Quantity

Crystal Pressure HPC41-300PSI-AHX Offers

Replace several gauges or calibrators with this handheld pressure calibrator, featuring an accuracy of up to 0.035% of reading. Experience no change in accuracy throughout the entire operating temperature range with this calibrator that is fully temperature compensated. In addition, inputs are included for mA, voltage, and switch testing.

Features

  • Advanced simplicity "non-menu" interface: Easy to use single layer user interface and no deep menu structure! (operate and set up this pressure calibrator to perform your tasks quickly and intuitively)
  • Store and recall previously used screens
  • "Wireless" keypad: All input and output connectors are placed away from the display and keypad to give maximum freedom to operate
  • Mini-USB port: Customize the set-up through free CrystalControl software
  • Function buttons: The function of each button is clearly explained in the bottom of the display
  • Color display: The new large full-color display combined with the advanced simplicity of the new user interface, makes this pressure calibrator the easiest-to-use pressure calibrator available
  • Cursor keys: Cursor keys help you to navigate through the display to perform set up functions and ne tune values
  • Difirential pressure: Read differential pressure between any of the three available sensors including the external APM CPF series module (sold separately) and a special tare feature allows you to normalize both readings at elevated static pressures, resulting in a more accurate differential pressure.
  • Intelligent memory slots: This pressure calibrator can store up to 5 screens (both upper and lower windows) and the next time you need to perform your test, simply recall the previous stored settings and this pressure calibrator is ready to use
  • Dampening: If testing a pulsating pressure signal, use the dampening feature to smooth out the measurements, making them easier to read
  • Minimum/maximum: With an update rate of 10 readings per second, this pressure calibrator is perfect for pressure safety valve testing
  • Leak rate: This pressure calibrator offers continuous measurement of rate/stability
  • Active temperature compensation: This pressure calibrator is the world's first combined pressure and mA loop calibrator to be fully temperature compensated from -4 to 122°F (-20 to 50°C) and you can count on the same accuracy whether measuring pressure, current, voltage, or temperature (temperature sensor sold separately)
  • 0.035% of reading accuracy
  • Measure and source mA with external loop power or internal 24 V DC power supply
  • Full set of electrical connections
  • Deadweight tester accuracy in a modern digital package
  • Back button: Press the (back) button to cancel a selection or to return to a previous menu
  • Enter button: Press the (back) button to cancel a selection or to return to a previous menu
  • ON/OFF power button

Current, voltage, switch test

Full 0 to 24 mA loop calibrator. Measure and source (including step and ramp) with external loop power or internal 24 V DC loop power supply. On top of that it also measures 0 to 55 mA. Use the high speed switch mode screen to detect switch open and closures.

Scaling

When testing a transmitter, it can be beneficial to view the input in units other than mA. For example, if measuring a 4-20 signal on a 0 to 30 psi transmitter, the upper display will show 12 mA when 15 psi is applied. This pressure calibrator will perform this calculation for you, displaying the mA value as psi.

% Error calculation

This pressure calibrator can calculate pressure vs. mA error as a percentage of the 4-20 mA loop span. For example, if you are testing a 30 psi full scale pressure transmitter with a corresponding 4-20 mA signal, you can program into the calibrator a 0 to 30 psi pressure span, and it will calculate and display the percent error in addition to the mA reading. This eliminates the need to manually calculate the error percentage.

Calibrate with confidence anywhere

Take measurements with up to 0.035% of reading accuracy. This pressure calibrator includes an ISO 17025 calibration report - NIST traceable, A2LA accredited (#2601.01), internationally recognized by ILAC - with test data at 5 temperatures, proving our calibrators meet specifications throughout their full temperature range. Other manufacturers charge extra for a report with data only at room temperature

Fittings for life

Crystal Pressure Fittings (sold separately) are machined in high-strength 316 stainless steel to operate at 10,000 psi/700 bar. Removable CPF adapters shift everyday thread wear away from this pressure calibrators ports, while a self-venting weep hole alerts you before you disconnect from a pressurized system.

Features that require the use of the free CrystalControl software

  • Remove: Unwanted pressure units
  • Auto off: Adjust automatic shutoff settings
  • Calibration: Calibrate the modules and enter new calibrated on and calibration due dates
  • User defined unit: Define and display any pressure units not included, or to use the gauge to display force, level or other pressure related parameters

Automatic shutoff-low power mode

To optimize battery life, adjust your Automatic Shutoff time (shut off time in absence of key press) on the unit or through the free CrystalControl software. This feature is adjustable from 5 minutes to "always on". When powered by USB, this calibrator does not employ any power management strategies. Therefore, it will not automatically shut off to the settings defined by CrystalControl.

Navigation

Arrow buttons: The (arrow) buttons serve different functions depending on the mode of operation. Press any of the four (arrow) buttons to enter "Navigation Mode". In this mode, the user can scroll through editable fields directly onscreen. Any field that can be edited will be highlighted in blue

  • Navigation mode: Use the four (arrow) buttons to move the cursor in the desired direction
  • Edit mode: Use the up and down (arrow) buttons to scroll through lists of options or, if entering a number, use the left and right (arrow) buttons to move the cursor one character in the desired direction

Zero button

Press the (zero) button to activate the function key options. This calibrator will display the parameters that are currently shown on the upper and lower displays. Press the (function) button for the parameter that you would like to zero. The display will then briefly flash all dashed lines (-----), indicating that it has been zeroed.
Note: If you attempt to zero the gauge with more pressure applied than the zero limit set on this calibrator (or with CrystalControl) the command will be ignored, and over zero Limit will display.

Applications

  • Small tool type jobs
  • Complex calibration jobs in custody transfer systems

Crystal Pressure HPC41-300PSI-AHX Specifications

Range 0 to 300 psi
Number of Sensors 1
Over Pressure 2.0 x
Display Screen: 320 x 240 pixel graphical display
Rate: 3 readings/second (standard) and 10 readings/second (switch test and peak hi/lo modes)
LCD readable in sunlight
Resolution:
psi: 0.01
"H2O: 0.1
"Hg: 0.01
mm Hg: 0.12: 0.001
bar: 0.001
mbar: 1
kPa: 0.1
MPa: 0.0001
Accuracy 18 to 28°C:
0 to 30% of range: ±(0.01% of full scale)
30 to 110% of range: ±(0.035% of reading)
Vacuum*: ±(0.05% of full scale**)

-20 to 50°C:
0 to 30% of range: ±(0.015% of full scale)
30 to 110% of range: ±(0.05% of reading)
Vacuum*: ±(0.05% of full scale**)

*Applies to 300 psi and lower ranges only. Vacuum range = -14.5 psi.
** Full scale is the numerical value of the positive pressure range
Pressure Sensor Wetted materials:
Wrench tight 316 stainless steel
Finger tight 316 stainless steel and Viton (internal o-ring)
Diaphragm seal fluid: Silicone oil
Connection: Crystal CPF female
All welded, with a permanently filled diaphragm seal
Metal to metal cone seal; O-ring can be removed if necessary
¼" medium pressure tube system compatible with HIP LM4 and LF4 series, Autoclave Engr SF250CX male and female series
¼" male NPT adapter included unless BSP, M20, or 15KPSI is specified
Pump System System A (AHX):
Pressure range: 0 to 580 psi/40 bar
Pneumatic: Yes
Hand pump: Yes
Included pump: T-970-CPF
Case options "aluminum or waterproof (pelican case)": Yes
Current and Voltage Measurement Connection: 4 mm jacks
Maximum voltages: 45 V DC
Current (mA) Input:
Accuracy: ±(0.015% of rdg + 0.002 mA)
mA range: 0 to 55 mA
Percent range: 0 to 20, 4 to 20, 10 to 50
Maximum allowable current: 60 mA
Resolution: 0.0001 mA or 0.01%
Units: mA and %
Input resistance: <17.2 Ω
Voltage burden at 20 mA: <0.35 V
Voltage burden at 50 mA: <0.86 V
HART resistor: 250 Ω
Inputs protected by a resettable fuse
mA can be displayed as a percentage, where 0 to 100% corresponds to either 0 to 20, 4 to 20, or 10 to 50 mA
Jacks are compatible with safety sheathed banana plugs

Output:
Accuracy: ±(0.015 of rdg + 0.002 mA)
Range: 0 to 25 mA
Step time: 1 to 999 seconds
Ramp time: 5 to 999 seconds
With internal or external loop supply
Voltage (VDC) Input Accuracy: ±(0.015 % of rdg + 2 mV)
Range: 0 to 30 V DC
Resolution: 0.001 V DC
Input impedance: >1 MΩ
Loop Power Fixed output: 24 V DC
Voltage output accuracy: ±10%
Maximum output current: 25 mA
Switch Test Switch type: Dry contact
Closed state resistance: <1 KΩ
Open state resistance: >100 KΩ
Sample rate: 10 Hz
Switch test screen reports switch open, close, and deadband values
Temperature Measurement:
Accuracy: ±(0.015% of rdg) + 0.02 Ω
Range: 0 to 400 Ω
Resolution: 0.01 on all scales
Units: °C, K, °F, R, Ω
TCR: 0.003850 Ω/Ω/°C (IEC 60751)
Wiring: 2-, 3-, and 4-wire support
Connection: Lemo plug, 1S series, 304 insert configuration
The proper selection of the RTD sensing element is very important as the error associated with this device is the majority of the overall system measurement uncertainty. IEC 751 is the standard that defines the temperature versus resistance for 100 Ω, 0.00385 Ω/Ω/°C platinum RTDs. IEC 751 defines two classes of RTDs: Class A and B. Class A RTDs operate over the -200 to 630°C range versus -200 to 800°C for the Class B elements. For example, the Class A uncertainty is about half that of the Class B elements

Operating: -4 to 122°F (-20 to 50°C), <95% RH, non-condensing. No change in pressure, electrical, or temperature accuracy over operating temperature range. Gauge must be zeroed to achieve rated specification
Storage: -40 to 167°F (-40 to 75°C), batteries should be removed if stored for more than one month
Data Communication Digital interface: mini-USB
The mini USB will power the nVision with or without the battery pack installed
Keypad and Labels UV resistant silicone
Power Uses 4 x alkaline AA (LR6) batteries
Battery life: >12 hours non-sourcing and >8 hours when sourcing 12 mA
Recharge time: 16 hours* (using Eneloop 2100 mA hr)
*Charging is done through USB , except when supplying loop power in mA, Int. Pwr. Mode.
Acceptable Batteries Alkaline (1.5 V cell voltage)
NiMH (1.2 V cell voltage)
Lithium (1.5 V cell voltage)
Housing Machined aluminum
Rating IP65
Certifications Complies with the Electromagnetic Compatibility and the Pressure Equipment Directives
Complies with the Australian Radiocommunications (Electromagnetic Compatibility) Standard 2008
Dimensions 3.49 x 1.63 x 6.94" (88.6 x 41.5 x 176.3 mm)
Weight 1.5 lbs (689 g)
Click here for complete specifications on the Crystal Pressure HPC41-300PSI-AHX

What's included with the Crystal Pressure HPC41-300PSI-AHX

  • Pressure Calibrator
  • ISO 17025 Accredited Calibration Certificate, NIST Traceable
  • Test Leads (Red and Black with Clips)
  • Your Choice of Adapters (NPT, BSP, and M20)
  • Protective Boot
  • Velco strap
  • Mini-USB Cable
  • 4 x AA Batteries
  • User Manual
  • One-Year Warranty

Ask a question about AMETEK Crystal HPC41 Pressure Calibrator with the AHX system A, single sensor, 0 to 300 psi

Customer Reviews for the Crystal Pressure HPC41-300PSI-AHX

Crystal Pressure HPC41-300PSI-AHX Offers

Replace several gauges or calibrators with this handheld pressure calibrator, featuring an accuracy of up to 0.035% of reading. Experience no change in accuracy throughout the entire operating temperature range with this calibrator that is fully temperature compensated. In addition, inputs are included for mA, voltage, and switch testing.

Features

  • Advanced simplicity "non-menu" interface: Easy to use single layer user interface and no deep menu structure! (operate and set up this pressure calibrator to perform your tasks quickly and intuitively)
  • Store and recall previously used screens
  • "Wireless" keypad: All input and output connectors are placed away from the display and keypad to give maximum freedom to operate
  • Mini-USB port: Customize the set-up through free CrystalControl software
  • Function buttons: The function of each button is clearly explained in the bottom of the display
  • Color display: The new large full-color display combined with the advanced simplicity of the new user interface, makes this pressure calibrator the easiest-to-use pressure calibrator available
  • Cursor keys: Cursor keys help you to navigate through the display to perform set up functions and ne tune values
  • Difirential pressure: Read differential pressure between any of the three available sensors including the external APM CPF series module (sold separately) and a special tare feature allows you to normalize both readings at elevated static pressures, resulting in a more accurate differential pressure.
  • Intelligent memory slots: This pressure calibrator can store up to 5 screens (both upper and lower windows) and the next time you need to perform your test, simply recall the previous stored settings and this pressure calibrator is ready to use
  • Dampening: If testing a pulsating pressure signal, use the dampening feature to smooth out the measurements, making them easier to read
  • Minimum/maximum: With an update rate of 10 readings per second, this pressure calibrator is perfect for pressure safety valve testing
  • Leak rate: This pressure calibrator offers continuous measurement of rate/stability
  • Active temperature compensation: This pressure calibrator is the world's first combined pressure and mA loop calibrator to be fully temperature compensated from -4 to 122°F (-20 to 50°C) and you can count on the same accuracy whether measuring pressure, current, voltage, or temperature (temperature sensor sold separately)
  • 0.035% of reading accuracy
  • Measure and source mA with external loop power or internal 24 V DC power supply
  • Full set of electrical connections
  • Deadweight tester accuracy in a modern digital package
  • Back button: Press the (back) button to cancel a selection or to return to a previous menu
  • Enter button: Press the (back) button to cancel a selection or to return to a previous menu
  • ON/OFF power button

Current, voltage, switch test

Full 0 to 24 mA loop calibrator. Measure and source (including step and ramp) with external loop power or internal 24 V DC loop power supply. On top of that it also measures 0 to 55 mA. Use the high speed switch mode screen to detect switch open and closures.

Scaling

When testing a transmitter, it can be beneficial to view the input in units other than mA. For example, if measuring a 4-20 signal on a 0 to 30 psi transmitter, the upper display will show 12 mA when 15 psi is applied. This pressure calibrator will perform this calculation for you, displaying the mA value as psi.

% Error calculation

This pressure calibrator can calculate pressure vs. mA error as a percentage of the 4-20 mA loop span. For example, if you are testing a 30 psi full scale pressure transmitter with a corresponding 4-20 mA signal, you can program into the calibrator a 0 to 30 psi pressure span, and it will calculate and display the percent error in addition to the mA reading. This eliminates the need to manually calculate the error percentage.

Calibrate with confidence anywhere

Take measurements with up to 0.035% of reading accuracy. This pressure calibrator includes an ISO 17025 calibration report - NIST traceable, A2LA accredited (#2601.01), internationally recognized by ILAC - with test data at 5 temperatures, proving our calibrators meet specifications throughout their full temperature range. Other manufacturers charge extra for a report with data only at room temperature

Fittings for life

Crystal Pressure Fittings (sold separately) are machined in high-strength 316 stainless steel to operate at 10,000 psi/700 bar. Removable CPF adapters shift everyday thread wear away from this pressure calibrators ports, while a self-venting weep hole alerts you before you disconnect from a pressurized system.

Features that require the use of the free CrystalControl software

  • Remove: Unwanted pressure units
  • Auto off: Adjust automatic shutoff settings
  • Calibration: Calibrate the modules and enter new calibrated on and calibration due dates
  • User defined unit: Define and display any pressure units not included, or to use the gauge to display force, level or other pressure related parameters

Automatic shutoff-low power mode

To optimize battery life, adjust your Automatic Shutoff time (shut off time in absence of key press) on the unit or through the free CrystalControl software. This feature is adjustable from 5 minutes to "always on". When powered by USB, this calibrator does not employ any power management strategies. Therefore, it will not automatically shut off to the settings defined by CrystalControl.

Navigation

Arrow buttons: The (arrow) buttons serve different functions depending on the mode of operation. Press any of the four (arrow) buttons to enter "Navigation Mode". In this mode, the user can scroll through editable fields directly onscreen. Any field that can be edited will be highlighted in blue

  • Navigation mode: Use the four (arrow) buttons to move the cursor in the desired direction
  • Edit mode: Use the up and down (arrow) buttons to scroll through lists of options or, if entering a number, use the left and right (arrow) buttons to move the cursor one character in the desired direction

Zero button

Press the (zero) button to activate the function key options. This calibrator will display the parameters that are currently shown on the upper and lower displays. Press the (function) button for the parameter that you would like to zero. The display will then briefly flash all dashed lines (-----), indicating that it has been zeroed.
Note: If you attempt to zero the gauge with more pressure applied than the zero limit set on this calibrator (or with CrystalControl) the command will be ignored, and over zero Limit will display.

Applications

  • Small tool type jobs
  • Complex calibration jobs in custody transfer systems

Crystal Pressure HPC41-300PSI-AHX Specifications

Range 0 to 300 psi
Number of Sensors 1
Over Pressure 2.0 x
Display Screen: 320 x 240 pixel graphical display
Rate: 3 readings/second (standard) and 10 readings/second (switch test and peak hi/lo modes)
LCD readable in sunlight
Resolution:
psi: 0.01
"H2O: 0.1
"Hg: 0.01
mm Hg: 0.12: 0.001
bar: 0.001
mbar: 1
kPa: 0.1
MPa: 0.0001
Accuracy 18 to 28°C:
0 to 30% of range: ±(0.01% of full scale)
30 to 110% of range: ±(0.035% of reading)
Vacuum*: ±(0.05% of full scale**)

-20 to 50°C:
0 to 30% of range: ±(0.015% of full scale)
30 to 110% of range: ±(0.05% of reading)
Vacuum*: ±(0.05% of full scale**)

*Applies to 300 psi and lower ranges only. Vacuum range = -14.5 psi.
** Full scale is the numerical value of the positive pressure range
Pressure Sensor Wetted materials:
Wrench tight 316 stainless steel
Finger tight 316 stainless steel and Viton (internal o-ring)
Diaphragm seal fluid: Silicone oil
Connection: Crystal CPF female
All welded, with a permanently filled diaphragm seal
Metal to metal cone seal; O-ring can be removed if necessary
¼" medium pressure tube system compatible with HIP LM4 and LF4 series, Autoclave Engr SF250CX male and female series
¼" male NPT adapter included unless BSP, M20, or 15KPSI is specified
Pump System System A (AHX):
Pressure range: 0 to 580 psi/40 bar
Pneumatic: Yes
Hand pump: Yes
Included pump: T-970-CPF
Case options "aluminum or waterproof (pelican case)": Yes
Current and Voltage Measurement Connection: 4 mm jacks
Maximum voltages: 45 V DC
Current (mA) Input:
Accuracy: ±(0.015% of rdg + 0.002 mA)
mA range: 0 to 55 mA
Percent range: 0 to 20, 4 to 20, 10 to 50
Maximum allowable current: 60 mA
Resolution: 0.0001 mA or 0.01%
Units: mA and %
Input resistance: <17.2 Ω
Voltage burden at 20 mA: <0.35 V
Voltage burden at 50 mA: <0.86 V
HART resistor: 250 Ω
Inputs protected by a resettable fuse
mA can be displayed as a percentage, where 0 to 100% corresponds to either 0 to 20, 4 to 20, or 10 to 50 mA
Jacks are compatible with safety sheathed banana plugs

Output:
Accuracy: ±(0.015 of rdg + 0.002 mA)
Range: 0 to 25 mA
Step time: 1 to 999 seconds
Ramp time: 5 to 999 seconds
With internal or external loop supply
Voltage (VDC) Input Accuracy: ±(0.015 % of rdg + 2 mV)
Range: 0 to 30 V DC
Resolution: 0.001 V DC
Input impedance: >1 MΩ
Loop Power Fixed output: 24 V DC
Voltage output accuracy: ±10%
Maximum output current: 25 mA
Switch Test Switch type: Dry contact
Closed state resistance: <1 KΩ
Open state resistance: >100 KΩ
Sample rate: 10 Hz
Switch test screen reports switch open, close, and deadband values
Temperature Measurement:
Accuracy: ±(0.015% of rdg) + 0.02 Ω
Range: 0 to 400 Ω
Resolution: 0.01 on all scales
Units: °C, K, °F, R, Ω
TCR: 0.003850 Ω/Ω/°C (IEC 60751)
Wiring: 2-, 3-, and 4-wire support
Connection: Lemo plug, 1S series, 304 insert configuration
The proper selection of the RTD sensing element is very important as the error associated with this device is the majority of the overall system measurement uncertainty. IEC 751 is the standard that defines the temperature versus resistance for 100 Ω, 0.00385 Ω/Ω/°C platinum RTDs. IEC 751 defines two classes of RTDs: Class A and B. Class A RTDs operate over the -200 to 630°C range versus -200 to 800°C for the Class B elements. For example, the Class A uncertainty is about half that of the Class B elements

Operating: -4 to 122°F (-20 to 50°C), <95% RH, non-condensing. No change in pressure, electrical, or temperature accuracy over operating temperature range. Gauge must be zeroed to achieve rated specification
Storage: -40 to 167°F (-40 to 75°C), batteries should be removed if stored for more than one month
Data Communication Digital interface: mini-USB
The mini USB will power the nVision with or without the battery pack installed
Keypad and Labels UV resistant silicone
Power Uses 4 x alkaline AA (LR6) batteries
Battery life: >12 hours non-sourcing and >8 hours when sourcing 12 mA
Recharge time: 16 hours* (using Eneloop 2100 mA hr)
*Charging is done through USB , except when supplying loop power in mA, Int. Pwr. Mode.
Acceptable Batteries Alkaline (1.5 V cell voltage)
NiMH (1.2 V cell voltage)
Lithium (1.5 V cell voltage)
Housing Machined aluminum
Rating IP65
Certifications Complies with the Electromagnetic Compatibility and the Pressure Equipment Directives
Complies with the Australian Radiocommunications (Electromagnetic Compatibility) Standard 2008
Dimensions 3.49 x 1.63 x 6.94" (88.6 x 41.5 x 176.3 mm)
Weight 1.5 lbs (689 g)
Click here for complete specifications on the Crystal Pressure HPC41-300PSI-AHX

What's included with the Crystal Pressure HPC41-300PSI-AHX

  • Pressure Calibrator
  • ISO 17025 Accredited Calibration Certificate, NIST Traceable
  • Test Leads (Red and Black with Clips)
  • Your Choice of Adapters (NPT, BSP, and M20)
  • Protective Boot
  • Velco strap
  • Mini-USB Cable
  • 4 x AA Batteries
  • User Manual
  • One-Year Warranty