AMETEK Crystal HPC40 Pressure Calibrator with BXX, dual sensor, 30 psi/3000 psi

Model: HPC42-30PSI-3KPSI-BXX

AMETEK Crystal HPC40 Pressure Calibrator with BXX, dual sensor, 30 psi/3000 psi

Model: HPC42-30PSI-3KPSI-BXX

Combined pressure and mA loop measurements to be fully temperature compensated from -4 to 122°F (-20 to 50°C), this dual pressure calibrator has a pneumatic hand pump with -25 inHg to 30 psi/- 0.91 to 2 bar range. Reliable accuracy in measuring pressure, current, voltage, or temperature.

Combined pressure and mA loop measurements to be fully temperature compensated from -4 to 122°F (-20 to 50°C), this dual pressure calibrator has a pneumatic hand pump with -25 inHg to 30 psi/- 0.91 to 2 bar range. Reliable accuracy in measuring pressure, current, voltage, or temperature.

Sale Price $5975.01 USD
Regular Price $6066.00 USD
Availability 2 to 3 Weeks
Quantity

Crystal Pressure HPC42-30PSI-3KPSI-BXX Offers

Used in a broad range of applications from simple tool type jobs to complex calibration jobs in custody transfer systems.

Features

  • 0.035% of reading accuracy
  • Gauge, absolute, and differential pressure to 15,000 psi/1000 bar/100 MPa
  • Advanced simplicity "non-menu" interface
  • Measure and source mA with external loop power or internal 24 VDC power supply
  • High accuracy thermometer with "true Ohm" technology
  • Store and recall previously used screens
  • Flexible power options including rechargeable

Applications

  • Pressure, current, voltage, and temperature measurement

Crystal Pressure HPC42-30PSI-3KPSI-BXX Specifications

Pressure Ranges 30 psi/3000 psi
Accuracy 0 to 30% of range: ±(0.015% of full scale)
30 to 110% of range: ±(0.050% of reading)
Vacuum : ±(0.05% of full scale)
Pressure Sensor Wetted materials: (wrench tight) 316 stainless steel, (finger tight) 316 stainless steel, and Viton (internal o-ring)
Diaphragm seal fluid: silicone oil
Connection: crystal CPF female
Current and Voltage Measurement Connection: 4 mm jacks
Maximum voltage: 45 VDC
Current (mA) input accuracy: ±(0.015% of rdg + 0.002 mA), mA range: 0 to 55 mA
Current (mA) output accuracy: ±(0.015 of rdg + 0.002 mA), range: 0 to 25 mA
Voltage (VDC) Input accuracy: ±(0.015 % of rdg + 2 mV), range: 0 to 30 VDC
Loop power accuracy: ±(0.015% of rdg) + 0.02 Ω, Range: 0 to 400 Ω
Enclosure Rating: IP65
Housing: machined aluminum
Keypad and labels: UV resistant silicone
Display 320 x 240 pixel graphical display
Temperature Range -4 to 122°F (-20 to 50°C)
Power Battery Life: >12 hours non-sourcing
>8 hours when sourcing 12 mA
BXX Pump System T-965 pneumatic hand pump: -25 inHg to 30 psi/-0.91 to 2 bar
Click here for complete specifications on the Crystal Pressure HPC42-30PSI-3KPSI-BXX

What's included with the Crystal Pressure HPC42-30PSI-3KPSI-BXX

  • Calibrator
  • ISO 17025 Accredited Calibration Certificate, NIST Traceable
  • BXX Pump System
  • Adapters
  • Protective Boot
  • Test Leads, Red and Black with Clips
  • Velco Strap
  • Mini-USB Cable
  • Pneumatic Hand Pump
  • 4 x Batteries
  • Aluminum Carrying Case
  • User Manual

Ask a question about AMETEK Crystal HPC40 Pressure Calibrator with BXX, dual sensor, 30 psi/3000 psi

Customer Reviews for the Crystal Pressure HPC42-30PSI-3KPSI-BXX

Crystal Pressure HPC42-30PSI-3KPSI-BXX Offers

Used in a broad range of applications from simple tool type jobs to complex calibration jobs in custody transfer systems.

Features

  • 0.035% of reading accuracy
  • Gauge, absolute, and differential pressure to 15,000 psi/1000 bar/100 MPa
  • Advanced simplicity "non-menu" interface
  • Measure and source mA with external loop power or internal 24 VDC power supply
  • High accuracy thermometer with "true Ohm" technology
  • Store and recall previously used screens
  • Flexible power options including rechargeable

Applications

  • Pressure, current, voltage, and temperature measurement

Crystal Pressure HPC42-30PSI-3KPSI-BXX Specifications

Pressure Ranges 30 psi/3000 psi
Accuracy 0 to 30% of range: ±(0.015% of full scale)
30 to 110% of range: ±(0.050% of reading)
Vacuum : ±(0.05% of full scale)
Pressure Sensor Wetted materials: (wrench tight) 316 stainless steel, (finger tight) 316 stainless steel, and Viton (internal o-ring)
Diaphragm seal fluid: silicone oil
Connection: crystal CPF female
Current and Voltage Measurement Connection: 4 mm jacks
Maximum voltage: 45 VDC
Current (mA) input accuracy: ±(0.015% of rdg + 0.002 mA), mA range: 0 to 55 mA
Current (mA) output accuracy: ±(0.015 of rdg + 0.002 mA), range: 0 to 25 mA
Voltage (VDC) Input accuracy: ±(0.015 % of rdg + 2 mV), range: 0 to 30 VDC
Loop power accuracy: ±(0.015% of rdg) + 0.02 Ω, Range: 0 to 400 Ω
Enclosure Rating: IP65
Housing: machined aluminum
Keypad and labels: UV resistant silicone
Display 320 x 240 pixel graphical display
Temperature Range -4 to 122°F (-20 to 50°C)
Power Battery Life: >12 hours non-sourcing
>8 hours when sourcing 12 mA
BXX Pump System T-965 pneumatic hand pump: -25 inHg to 30 psi/-0.91 to 2 bar
Click here for complete specifications on the Crystal Pressure HPC42-30PSI-3KPSI-BXX

What's included with the Crystal Pressure HPC42-30PSI-3KPSI-BXX

  • Calibrator
  • ISO 17025 Accredited Calibration Certificate, NIST Traceable
  • BXX Pump System
  • Adapters
  • Protective Boot
  • Test Leads, Red and Black with Clips
  • Velco Strap
  • Mini-USB Cable
  • Pneumatic Hand Pump
  • 4 x Batteries
  • Aluminum Carrying Case
  • User Manual