Ideal for electronics engineers, technicians, and field service, this multimeter features a TTL logic test for digital circuits, a diode test for component-level troubleshooting, a 2000 MΩ measurement range, and an integrated tilt stand for convenience on the bench.
Ideal for electronics engineers, technicians, and field service, this multimeter features a TTL logic test for digital circuits, a diode test for component-level troubleshooting, a 2000 MΩ measurement range, and an integrated tilt stand for convenience on the bench.
Features
Display | 3-1/2 digit liquid crystal display (LCD) with a maximum reading of 1999 |
Polarity | Automatic, positive implied, negative polarity indication |
Over-range | (OL) or (-OL) is displayed |
Zero | Automatic |
Low battery indication | The + is displayed when the battery voltage drops below the operating level |
Auto power off | Approx. 10 minutes |
Measurement rate | 2 times per second, nominal |
Operating environment | 32 to 122°F (0 to 50°C) at <70 % R.H. |
Accuracy | Stated accuracy at 23 °C ± 5 °C, <75 % relative humidity |
Power | Single standard 9 volt battery, NEDA 1604, JIS 006P, IEC 6F22 |
DC Volt ranges | 200 mV, 2 V, 20 V, 200 V, 600 V Accuracy: ± (0.5 % rdg + 1 dgt) |
AC Volts (45 Hz to 500 Hz) Ranges | 200 mV 2 V, 20 V, 200 V, 600 V Accuracy: ± (1.5 % rdg + 5 dgts) |
DC Current Ranges | 200 µA, 2000 µA, 20 mA, 200 mA, Accuracy: ± (1.0 % rdg + 2 dgt) 2 A, Accuracy ± (2.0 % rdg + 3 dgts) |
AC Current (45 Hz to 500 Hz) Ranges | 200 µA, 2000 µA, 20 mA, 200 mA, Accuracy: ± (1.5 % rdg + 5 dgts) 2 A, Accuracy ± (2.5 % rdg + 5 dgts) |
Resistance | 200Ω, 2 kΩ , 20 kΩ , 200 kΩ , 2 MΩ ± (1.0 % rdg + 4 dgts) |
Resistance | 2000 MO ± {5.0 % (rdg -10 dgts) +20 dgt} |
Continuity Audible Indication | Less than 25Ω |
Diode test current | 1.2 mA (approximate) ±(1.5 % rdg + 3 dgts) |
Logic test | TTL |
Non-contact voltage indicator | Sense voltage 70 V to 600 V ac (50 Hz to 60 Hz) beeper chirps and big bright red LED comes on, works on all ranges |
Display | 3-1/2 digit liquid crystal display (LCD) with a maximum reading of 1999 |
Polarity | Automatic, positive implied, negative polarity indication |
Over-range | (OL) or (-OL) is displayed |
Zero | Automatic |
Low battery indication | The + is displayed when the battery voltage drops below the operating level |
Auto power off | Approx. 10 minutes |
Measurement rate | 2 times per second, nominal |
Operating environment | 32 to 122°F (0 to 50°C) at <70 % R.H. |
Accuracy | Stated accuracy at 23 °C ± 5 °C, <75 % relative humidity |
Power | Single standard 9 volt battery, NEDA 1604, JIS 006P, IEC 6F22 |
DC Volt ranges | 200 mV, 2 V, 20 V, 200 V, 600 V Accuracy: ± (0.5 % rdg + 1 dgt) |
AC Volts (45 Hz to 500 Hz) Ranges | 200 mV 2 V, 20 V, 200 V, 600 V Accuracy: ± (1.5 % rdg + 5 dgts) |
DC Current Ranges | 200 µA, 2000 µA, 20 mA, 200 mA, Accuracy: ± (1.0 % rdg + 2 dgt) 2 A, Accuracy ± (2.0 % rdg + 3 dgts) |
AC Current (45 Hz to 500 Hz) Ranges | 200 µA, 2000 µA, 20 mA, 200 mA, Accuracy: ± (1.5 % rdg + 5 dgts) 2 A, Accuracy ± (2.5 % rdg + 5 dgts) |
Resistance | 200Ω, 2 kΩ , 20 kΩ , 200 kΩ , 2 MΩ ± (1.0 % rdg + 4 dgts) |
Resistance | 2000 MO ± {5.0 % (rdg -10 dgts) +20 dgt} |
Continuity Audible Indication | Less than 25Ω |
Diode test current | 1.2 mA (approximate) ±(1.5 % rdg + 3 dgts) |
Logic test | TTL |
Non-contact voltage indicator | Sense voltage 70 V to 600 V ac (50 Hz to 60 Hz) beeper chirps and big bright red LED comes on, works on all ranges |