Work with fast and accurate refrigerant testing with this analyzer that reduces the need for costly and time-consuming gas chromatography. In addition, confirm purity while detecting the presence of other harmful refrigerants or air with this analyzer that can measure vapor or liquid refrigerant with a 0 to 100% range.
Work with fast and accurate refrigerant testing with this analyzer that reduces the need for costly and time-consuming gas chromatography. In addition, confirm purity while detecting the presence of other harmful refrigerants or air with this analyzer that can measure vapor or liquid refrigerant with a 0 to 100% range.
Suitable for multiple HVAC/R applications, this refrigerant analyzer allows you to analyze your refrigerant in less than two minutes. In addition, this analyzer stores test data for new refrigerants on an external USB drive and remote software.
Features
Indentify and analyze with confidence
In the last few years, there has been an emergence of new refrigerants in the market to support the F-Gas phasedown regulations. These more environmentally friendly refrigerants are sold as replacements or retrofits for high Ozone Depleting (ODP) or high Global Warming Potential (GWP) refrigerants. These new refrigerants are often meant to replace these high ODP or GWP refrigerants in older systems, but it is often very hard to determine if a new gas was added to or used in place of another refrigerant. Too often these refrigerants are meant to function like their less environmentally friendly predecessors, which means pressure/temperate (P/T) curves are going to be very similar to keep systems running efficiently. This increases difficulty in confirming a refrigerant is as expected without the use of a refrigerant analyzer.
No longer are there only a few familiar refrigerants in the market. There are new blends being released all the time and there is no sure way to know what refrigerant you are working with if you don't have a tool designed to analyze the gas. Simply assuming a refrigerant is right, or only relying on P/T charts, can cause more confusion and lead to mixing or inappropriate application use of refrigerants. Now more than ever it has become necessary to verify every refrigerant in a system or cylinder is correct to ensure that equipment runs effectively and efficiently. With the presence of only a small amount of air, a (P/T) analysis can fail and lead to costly service. Moreover, mixing refrigerants can lead to system failures and potentially put the user or unsuspecting service technician at risk of injury or harm.
This HFC refrigerant analyzer is the answer!
Confirming a refrigerant is the right gas before service or use will ensure all systems effectively operate while protecting the customer and the technician. The use of a refrigerant analyzer creates a cleaner recovery process and reduces the amount of mixed gas recovered. Reducing mix gas recovery will ultimately cut down on the amount of refrigerant that must be destroyed which helps improve the industry's ecological footprint.
A refrigerant analyzer is a valuable tool to safeguard users and equipment, while promoting recycling and reuse to protect the environment. This HFC refrigerant analyzer is the most advanced refrigerant analyzer in the market and provides the latest in NDIR technology to support refrigerant testing before use. Reduce the uncertainty and analyze every refrigerant before handling so you can ensure you are safeguarding yourself, your equipment, and the environment to certify the job is done right.
Applications
Measuring Range | 0 to 100% |
Accuracy | ±2% of single component refrigerants |
Display Size | 5" (127 mm) |
Ambient Temperature | 50 to 120°F (10 to 49°C) |
Humidity | 0 to 95% RH non-condensing |
Pressure | Adequate 30 to 500 psig (2 to 34 bar), pressures <30 psig (2 bar) allow added flow time |
Altitude | 0 to 8000' (2440 m) |
Refrigerants | Analyzed refrigerants (displays % purity): R-22, R-32, R-134a, R-404A, R-407C, R-410A, hydrocarbons (HC) and air Identified refrigerants (NO % purity): R-12, R-1234yf, R-408A, R-409A, R-417A,R-421A, R-421B, R-422A, R-422B, R-422C, R-427A |
Printer | Integrated thermal printer |
Power | 12 V DC at 2 A via 110/220 V AC, 50 to 60 Hz adapter |
Approvals | CE, UL, and CUL |
Weight | Less than 10 lbs (4.53 kg) |
Click on a category to view a selection of compatible accessories with the Bacharach Legend Series HFC Refrigerant Analyzer, 0 to 100%, ±2% of single component refrigerants.
Measuring Range | 0 to 100% |
Accuracy | ±2% of single component refrigerants |
Display Size | 5" (127 mm) |
Ambient Temperature | 50 to 120°F (10 to 49°C) |
Humidity | 0 to 95% RH non-condensing |
Pressure | Adequate 30 to 500 psig (2 to 34 bar), pressures <30 psig (2 bar) allow added flow time |
Altitude | 0 to 8000' (2440 m) |
Refrigerants | Analyzed refrigerants (displays % purity): R-22, R-32, R-134a, R-404A, R-407C, R-410A, hydrocarbons (HC) and air Identified refrigerants (NO % purity): R-12, R-1234yf, R-408A, R-409A, R-417A,R-421A, R-421B, R-422A, R-422B, R-422C, R-427A |
Printer | Integrated thermal printer |
Power | 12 V DC at 2 A via 110/220 V AC, 50 to 60 Hz adapter |
Approvals | CE, UL, and CUL |
Weight | Less than 10 lbs (4.53 kg) |
Click on a category to view a selection of compatible accessories with the Bacharach Legend Series HFC Refrigerant Analyzer, 0 to 100%, ±2% of single component refrigerants.