Provides exceptional accuracy with dual analog displays and coarse and fine voltage and current controls, this DC power supply features an output voltage of 0 to 60 V and an output current of 0 to 2 A. In addition, it operates continuously at full load without overheating and is fully overload protected.
Provides exceptional accuracy with dual analog displays and coarse and fine voltage and current controls, this DC power supply features an output voltage of 0 to 60 V and an output current of 0 to 2 A. In addition, it operates continuously at full load without overheating and is fully overload protected.
Features
Applications
Output | Voltage: 0 to 60 V Current: 0 to 2 A |
Constant Voltage Operation | Voltage regulation: Line (120 V AC ±10%) <0.01% + 3 mV; Load (no load - full load) <0.01% + 3 mV Recovery time: <100 μs Ripple and noise: <1 mV rms Temperature coefficient: <300 ppm/°C |
Constant Current Operation | Adjustable current limits: 5 to 100% Current regulation: Line (120 V AC ±10%) <0.2% + 3 mA; Load <0.2% + 3 mA Current ripple: <3 mArms |
Metering | Type: 4-digit LED Voltmeter range: 0 to 99.99 V (green) Voltmeter accuracy: ±(0.5% rdg +9 digits) Ammeter range: 0 to 9.999 A (high) Ammeter accuracy: ±(0.5% rdg +9 digits) |
Overload Protection | Current limiting, reverse polarity, overvoltage, short circuit |
Power | Requirements: 120 V AC ±10%, 60 Hz Consumption: 210 W |
Temperature | Operation: 32 to 104°F (0 to 40°C), <75% RH Storage: 5 to 158°F (-15 to 70°C), <85% RH |
Dimensions | 6.2 x 5.5 x 12.5" (157 x 140 x 318 mm) |
Weight | 12 lbs (5.4 kg) |
Output | Voltage: 0 to 60 V Current: 0 to 2 A |
Constant Voltage Operation | Voltage regulation: Line (120 V AC ±10%) <0.01% + 3 mV; Load (no load - full load) <0.01% + 3 mV Recovery time: <100 μs Ripple and noise: <1 mV rms Temperature coefficient: <300 ppm/°C |
Constant Current Operation | Adjustable current limits: 5 to 100% Current regulation: Line (120 V AC ±10%) <0.2% + 3 mA; Load <0.2% + 3 mA Current ripple: <3 mArms |
Metering | Type: 4-digit LED Voltmeter range: 0 to 99.99 V (green) Voltmeter accuracy: ±(0.5% rdg +9 digits) Ammeter range: 0 to 9.999 A (high) Ammeter accuracy: ±(0.5% rdg +9 digits) |
Overload Protection | Current limiting, reverse polarity, overvoltage, short circuit |
Power | Requirements: 120 V AC ±10%, 60 Hz Consumption: 210 W |
Temperature | Operation: 32 to 104°F (0 to 40°C), <75% RH Storage: 5 to 158°F (-15 to 70°C), <85% RH |
Dimensions | 6.2 x 5.5 x 12.5" (157 x 140 x 318 mm) |
Weight | 12 lbs (5.4 kg) |