Handheld and versatile, this multimeter features a 2000 count LCD with a bright blue backlight that allows the meter to be used in dimly lit environments. Also featured are an auto-ranging function, a magnetic hanger, and an auto power-off feature, avoiding accidental battery over-consumption.
Handheld and versatile, this multimeter features a 2000 count LCD with a bright blue backlight that allows the meter to be used in dimly lit environments. Also featured are an auto-ranging function, a magnetic hanger, and an auto power-off feature, avoiding accidental battery over-consumption.
Features
DC Volts | |
Ranges | 200 mV, 2000 mV, 20 V, 200 V 1000 V |
Resolution | 0.1 mV, 1 mV, 10 mV, 100 mV, 1 V |
Accuracy | ±(0.5% rdg + 1 dgts) |
Input Impedance | 10 MΩ |
Overload Protection | 1000 VDC or 750 VAC rms |
AC Volts (50 to 500 Hz) | |
Ranges | 200 mV, 2000 mV, 20 V, 200 V 750 V |
Resolution | 0.1 mV, 1 mV, 10 mV, 100 mV, 1 V |
Accuracy | 200 mV and 20 V ranges: ±(1.2% rdg + 5 dgts) 200 V and 750 V ranges: ±(2% rdg + 5 dgts) |
Input Impedance | 10 MΩ |
Overload Protection | 1000 VDC or 750 VAC rms |
DC Current | |
Ranges | 200 uA, 20 mA, 200 mA |
Resolution | 0.1 uA, 10 uA, 100 uA |
Accuracy | ±(1% rdg + 1 dgts) |
Input Protection | 0.25 A/500 V fast blow ceramic fuse |
AC Current (50 to 500 Hz) | |
Ranges | 200 uA, 20 mA, 200 mA |
Resolution | 0.1 uA, 10 uA, 100 uA |
Accuracy | ±(1.5% rdg + 5 dgts) |
Input Protection | 0.25 A/500 V fast blow ceramic fuse |
Resistance | |
Ranges | 200 Ω, 2 kΩ, 200 kΩ, 20 MΩ |
Resolution | 0.1 Ω, 1.0 Ω, 100 Ω, 10 kΩ |
Accuracy | 200 Ω to 200 kΩ ranges: ±(1% rdg + 4 dgts) 20 MΩ range: ±(2% rdg + 4 dgts) |
Open Circuit Voltage (Typical) | 0.3 VDC (3 VDC on 200 Ω) |
Overload Protection | 500 VDC/AC rms |
Capacitance | |
Ranges | 200 uF, 2 mF, 20 mF |
Resolution | 0.1 uF, 1 uF, 10 uF |
Accuracy | ±(4% rdg + 10 dgts) |
Overload Protection | 0.25 A/500 V fast blow ceramic fuse |
Frequency | |
Ranges | 10 Hz to 40 kHz |
Resolution | 1 Hz |
Accuracy | ±(0.1% rdg + 3 dgts) |
Sensitivity | 3.5 V rms minimum |
Overload Protection | 500 VDC/AC rms |
Diode Test | |
Test Current | 1 mA (typical) |
Resolution | 10 mV |
Accuracy | ±(1.5% rdg + 3 dgts) |
Open Circuit Voltage | 3 VDC (typical) |
Overload Protection | 500 VDC/AC rms |
Continuity | |
Audible Indication | Less than 100 Ω |
Response Time | 100 ms |
Overload Protection | 500 VDC/AC rms |
Temperature | |
Ranges | -30 to 1400°F (-35 to 750°C) |
Resolution | 0.1°F (0.1°C) |
Accuracy | 0 to 400°C ±(1% rdg + 1°C) -35 to 0°C, 400 to 750°C ±(3% rdg + 3°C) -4 to 750°F ±(1% rdg + 2°F) -30 to -4°F, 750 to 1400°F ±(3% rdg + 6°F) |
Sensor Type | Type-K thermocouple |
Overload Protection | 60 VDC or 30 VAC rms |
General Specifications | |
Display | 3½ digit, 2000 count LCD |
Measurement Rate | 2.5 times per second |
Auto Power Off | Approximately 25 minutes |
Temperature | Operating: 32 to 122°F (0 to 50°C) at < 70% relative humidity Storage: -4 to 140°F (-20 to 60°C) at 0 to 80% relative humidity Coefficient: 0.1 x (specified accuracy) per °F/C. (0 to 64.4°F [0 to 18°C], 82.4 to 122°F [28 to 50°C]) |
Power | Single standard 9 V battery, NEDA 1604, JIS 006P, IEC 6F22 |
Battery Life | 150 hours typical |
Dimensions | 6.49 x 3.07 x 1.67" (165 x 78 x 42.5 mm) |
Weight | 10 oz (285 g) |
DC Volts | |
Ranges | 200 mV, 2000 mV, 20 V, 200 V 1000 V |
Resolution | 0.1 mV, 1 mV, 10 mV, 100 mV, 1 V |
Accuracy | ±(0.5% rdg + 1 dgts) |
Input Impedance | 10 MΩ |
Overload Protection | 1000 VDC or 750 VAC rms |
AC Volts (50 to 500 Hz) | |
Ranges | 200 mV, 2000 mV, 20 V, 200 V 750 V |
Resolution | 0.1 mV, 1 mV, 10 mV, 100 mV, 1 V |
Accuracy | 200 mV and 20 V ranges: ±(1.2% rdg + 5 dgts) 200 V and 750 V ranges: ±(2% rdg + 5 dgts) |
Input Impedance | 10 MΩ |
Overload Protection | 1000 VDC or 750 VAC rms |
DC Current | |
Ranges | 200 uA, 20 mA, 200 mA |
Resolution | 0.1 uA, 10 uA, 100 uA |
Accuracy | ±(1% rdg + 1 dgts) |
Input Protection | 0.25 A/500 V fast blow ceramic fuse |
AC Current (50 to 500 Hz) | |
Ranges | 200 uA, 20 mA, 200 mA |
Resolution | 0.1 uA, 10 uA, 100 uA |
Accuracy | ±(1.5% rdg + 5 dgts) |
Input Protection | 0.25 A/500 V fast blow ceramic fuse |
Resistance | |
Ranges | 200 Ω, 2 kΩ, 200 kΩ, 20 MΩ |
Resolution | 0.1 Ω, 1.0 Ω, 100 Ω, 10 kΩ |
Accuracy | 200 Ω to 200 kΩ ranges: ±(1% rdg + 4 dgts) 20 MΩ range: ±(2% rdg + 4 dgts) |
Open Circuit Voltage (Typical) | 0.3 VDC (3 VDC on 200 Ω) |
Overload Protection | 500 VDC/AC rms |
Capacitance | |
Ranges | 200 uF, 2 mF, 20 mF |
Resolution | 0.1 uF, 1 uF, 10 uF |
Accuracy | ±(4% rdg + 10 dgts) |
Overload Protection | 0.25 A/500 V fast blow ceramic fuse |
Frequency | |
Ranges | 10 Hz to 40 kHz |
Resolution | 1 Hz |
Accuracy | ±(0.1% rdg + 3 dgts) |
Sensitivity | 3.5 V rms minimum |
Overload Protection | 500 VDC/AC rms |
Diode Test | |
Test Current | 1 mA (typical) |
Resolution | 10 mV |
Accuracy | ±(1.5% rdg + 3 dgts) |
Open Circuit Voltage | 3 VDC (typical) |
Overload Protection | 500 VDC/AC rms |
Continuity | |
Audible Indication | Less than 100 Ω |
Response Time | 100 ms |
Overload Protection | 500 VDC/AC rms |
Temperature | |
Ranges | -30 to 1400°F (-35 to 750°C) |
Resolution | 0.1°F (0.1°C) |
Accuracy | 0 to 400°C ±(1% rdg + 1°C) -35 to 0°C, 400 to 750°C ±(3% rdg + 3°C) -4 to 750°F ±(1% rdg + 2°F) -30 to -4°F, 750 to 1400°F ±(3% rdg + 6°F) |
Sensor Type | Type-K thermocouple |
Overload Protection | 60 VDC or 30 VAC rms |
General Specifications | |
Display | 3½ digit, 2000 count LCD |
Measurement Rate | 2.5 times per second |
Auto Power Off | Approximately 25 minutes |
Temperature | Operating: 32 to 122°F (0 to 50°C) at < 70% relative humidity Storage: -4 to 140°F (-20 to 60°C) at 0 to 80% relative humidity Coefficient: 0.1 x (specified accuracy) per °F/C. (0 to 64.4°F [0 to 18°C], 82.4 to 122°F [28 to 50°C]) |
Power | Single standard 9 V battery, NEDA 1604, JIS 006P, IEC 6F22 |
Battery Life | 150 hours typical |
Dimensions | 6.49 x 3.07 x 1.67" (165 x 78 x 42.5 mm) |
Weight | 10 oz (285 g) |