B&K Precision 880 Dual-Display Handheld LCR Meter, 40,000-count, 0.1%

Model: 880 | UPC: 783310164807

B&K Precision 880 Dual-Display Handheld LCR Meter, 40,000-count, 0.1%

Model: 880 | UPC: 783310164807

Measures inductance, capacitance, and resistance quickly and precisely, as well as impedance, Theta, and ESR. It offers 4-terminal configuration, basic measurement accuracy up to 0.1%, test frequencies up to 100 kHz, selectable test signal levels, and measurement rate.

Measures inductance, capacitance, and resistance quickly and precisely, as well as impedance, Theta, and ESR. It offers 4-terminal configuration, basic measurement accuracy up to 0.1%, test frequencies up to 100 kHz, selectable test signal levels, and measurement rate.

Sale Price $489.25 USD
Regular Price $515.00 USD
Availability 9 to 10 Weeks
Quantity

Traceable In-House Calibration Certificate for your 880 Dual-Display Handheld LCR Meter

Traceable In-House Calibration Certificate for your 880 Dual-Display Handheld LCR Meter

B&K 880 Offers

Fast auto ranging and quick measurement configuration such as measurement parameter and test frequency selection make these meters very simple to operate. The meter also includes handy functions such as data hold, Min/Max/Average recording, tolerance sorting, and relative mode. Measurement data can continuously transfer to a PC via the meter's mini USB interface, using either the provided data logging software or SCPI commands sent from a custom program.

Features

  • 40,000 counts resolution on primary and 10,000 counts resolution on secondary display
  • L, C, R, and Z primary measurements
  • Automatic calculation of secondary parameters D, Q, Theta, ESR, and DCR
  • Accuracy up to 0.1% and selectable test frequencies up to 100 kHz
  • Fast auto range design for rapid, easy component measurements
  • Auto detect mode for automatic component type identification and measurement type selection
  • Relative mode
  • Visible and audible tolerance mode
  • Backlit display
  • Data Hold and Min/Max/Average recording
  • USB (Virtual COM) interface
  • SCPI compliant commands for remote communication
  • Software for data logging and front panel emulation available as free download
  • Configurable power-up-states

ESR measurements

Ability to measure the ESR (Equivalent Series Resistance) of capacitors. ESR is the sum of in-phase AC resistance of a capacitor and used to rate a capacitor's quality. An ideal capacitor would be lossless and have an ESR of zero. A capacitor could measure the correct capacitance value, yet still be defective, due to the component's excessive in-phase AC resistance. It would be able to detect this faulty component.

Flexible operation

A tilt stand provides position flexibility for viewing and operating the meter. The over-molding rubber case protects the meter for better durability. A single 9 V battery (16 hours with alkaline battery) or the included 12 V power adapter can be used to power the meter, giving the user options for portable or bench-top use. It includes a rechargeable Ni-MH battery that can provide up to six hours of battery life.

Four-terminal shielded configuration

Provides a 4-terminal socket with separate sensing and current leads plus guard terminal, a configuration typically only found in bench LCR meters. When using the included 4-terminal Kelvin test leads, this configuration can reduce the effect of lead impedances and contact resistance. This minimizes measurement errors and improves accuracy especially in the lower impedance range.

Faster auto range

The advanced auto range circuit design allows for faster measurements without the need to manually select ranges.

Dual display

The dual display allows multiple measurements to be conveniently displayed at once.

Auto detect mode

With the push of a single button, the Auto detect function will automatically identify primary parameters L, C or R and related secondary parameters, and set the suitable series/parallel equivalent mode and range.

Applications

  • Passive component troubleshooting
  • Electronic assembly
  • Quality control (component sorting)

B&K 880 Specifications

Measurement Parameters L, C, R, Z, D, Q, θ, ESR and DCR
Test Frequency Setting 100 Hz,120 Hz, 1 kHz, 10 kHz, 100 kHz
Actual Frequency (±0.02%) 100 Hz, 120.048 Hz, 1 kHz, 10 kHz, 100 kHz
Tolerance Mode 1%, 5%, 10%, 20%
Backlit Display Yes
Test Signal Level (Typical) 0.3 Vrms, 0.6 Vrms, 1 Vrms
DCR signal: 1 Vdc
Measuring Circuit Mode Series mode/Parallel mode
Basic Accuracy 0.1%
Ranging Mode Auto
Measuring Terminals 3-terminal, 5-terminal with sockets
Measurement Rate LCRZ: 4 readings/sec (fast), 1.5 readings/sec (slow)
DCR: 3 readings/sec (fast), 2.5 readings/sec (slow)
Response Time (Typical) 680 ms
Auto Power-Off 5, 15, 30, 60 minutes, none
Operating Temperature 32 to 104°F (0 to 40°C); ≤90% RH
Storage Temperature -4 to 104° F (-20 to 50°C); 0 to 90% RH
Low Battery Indication (Typical) 6.8 V
Battery Life (Typical) 16 hours using alkaline battery (at 1 kHz with 100 Ω DUT, backlight off), 6 hours using Ni-MH
Power Consumption (Typical) 28 mA (under full power battery) for operation/11 μA after power-off
Power Requirements 9 V battery or ext. AC adapter: DC 12 Vmin to 15 Vmax (load 50 mA minimum)
Dimensions 7.5 x 3.5 x 1.6" (190 x 90 x 41 mm)
Weight 0.767 lbs (348 g) without battery
Safety EN61010-1:2001, EU Low Voltage Directive 2006/95/EC
Electromagnetic Compatibility Meets EMC Directive 2004/108/EC, EN61326-1:2006
Click here for complete specifications on the B&K 880

What's included with the B&K 880

  • LCR Meter
  • Banana-to-Alligator Test Leads
  • Shorting Plate
  • Four-Terminal Shielded Kelvin Clip Test Leads
  • SMD Tweezer
  • Mini USB Interface Cable
  • Ni-MH 9 V Battery
  • 120 V AC Adapter
  • Quick Start Insert

Ask a question about B&K Precision 880 Dual-Display Handheld LCR Meter, 40,000-count, 0.1%

Customer Reviews for the B&K 880

B&K 880 Offers

Fast auto ranging and quick measurement configuration such as measurement parameter and test frequency selection make these meters very simple to operate. The meter also includes handy functions such as data hold, Min/Max/Average recording, tolerance sorting, and relative mode. Measurement data can continuously transfer to a PC via the meter's mini USB interface, using either the provided data logging software or SCPI commands sent from a custom program.

Features

  • 40,000 counts resolution on primary and 10,000 counts resolution on secondary display
  • L, C, R, and Z primary measurements
  • Automatic calculation of secondary parameters D, Q, Theta, ESR, and DCR
  • Accuracy up to 0.1% and selectable test frequencies up to 100 kHz
  • Fast auto range design for rapid, easy component measurements
  • Auto detect mode for automatic component type identification and measurement type selection
  • Relative mode
  • Visible and audible tolerance mode
  • Backlit display
  • Data Hold and Min/Max/Average recording
  • USB (Virtual COM) interface
  • SCPI compliant commands for remote communication
  • Software for data logging and front panel emulation available as free download
  • Configurable power-up-states

ESR measurements

Ability to measure the ESR (Equivalent Series Resistance) of capacitors. ESR is the sum of in-phase AC resistance of a capacitor and used to rate a capacitor's quality. An ideal capacitor would be lossless and have an ESR of zero. A capacitor could measure the correct capacitance value, yet still be defective, due to the component's excessive in-phase AC resistance. It would be able to detect this faulty component.

Flexible operation

A tilt stand provides position flexibility for viewing and operating the meter. The over-molding rubber case protects the meter for better durability. A single 9 V battery (16 hours with alkaline battery) or the included 12 V power adapter can be used to power the meter, giving the user options for portable or bench-top use. It includes a rechargeable Ni-MH battery that can provide up to six hours of battery life.

Four-terminal shielded configuration

Provides a 4-terminal socket with separate sensing and current leads plus guard terminal, a configuration typically only found in bench LCR meters. When using the included 4-terminal Kelvin test leads, this configuration can reduce the effect of lead impedances and contact resistance. This minimizes measurement errors and improves accuracy especially in the lower impedance range.

Faster auto range

The advanced auto range circuit design allows for faster measurements without the need to manually select ranges.

Dual display

The dual display allows multiple measurements to be conveniently displayed at once.

Auto detect mode

With the push of a single button, the Auto detect function will automatically identify primary parameters L, C or R and related secondary parameters, and set the suitable series/parallel equivalent mode and range.

Applications

  • Passive component troubleshooting
  • Electronic assembly
  • Quality control (component sorting)

B&K 880 Specifications

Measurement Parameters L, C, R, Z, D, Q, θ, ESR and DCR
Test Frequency Setting 100 Hz,120 Hz, 1 kHz, 10 kHz, 100 kHz
Actual Frequency (±0.02%) 100 Hz, 120.048 Hz, 1 kHz, 10 kHz, 100 kHz
Tolerance Mode 1%, 5%, 10%, 20%
Backlit Display Yes
Test Signal Level (Typical) 0.3 Vrms, 0.6 Vrms, 1 Vrms
DCR signal: 1 Vdc
Measuring Circuit Mode Series mode/Parallel mode
Basic Accuracy 0.1%
Ranging Mode Auto
Measuring Terminals 3-terminal, 5-terminal with sockets
Measurement Rate LCRZ: 4 readings/sec (fast), 1.5 readings/sec (slow)
DCR: 3 readings/sec (fast), 2.5 readings/sec (slow)
Response Time (Typical) 680 ms
Auto Power-Off 5, 15, 30, 60 minutes, none
Operating Temperature 32 to 104°F (0 to 40°C); ≤90% RH
Storage Temperature -4 to 104° F (-20 to 50°C); 0 to 90% RH
Low Battery Indication (Typical) 6.8 V
Battery Life (Typical) 16 hours using alkaline battery (at 1 kHz with 100 Ω DUT, backlight off), 6 hours using Ni-MH
Power Consumption (Typical) 28 mA (under full power battery) for operation/11 μA after power-off
Power Requirements 9 V battery or ext. AC adapter: DC 12 Vmin to 15 Vmax (load 50 mA minimum)
Dimensions 7.5 x 3.5 x 1.6" (190 x 90 x 41 mm)
Weight 0.767 lbs (348 g) without battery
Safety EN61010-1:2001, EU Low Voltage Directive 2006/95/EC
Electromagnetic Compatibility Meets EMC Directive 2004/108/EC, EN61326-1:2006
Click here for complete specifications on the B&K 880

What's included with the B&K 880

  • LCR Meter
  • Banana-to-Alligator Test Leads
  • Shorting Plate
  • Four-Terminal Shielded Kelvin Clip Test Leads
  • SMD Tweezer
  • Mini USB Interface Cable
  • Ni-MH 9 V Battery
  • 120 V AC Adapter
  • Quick Start Insert

Ask a question about B&K Precision 880 Dual-Display Handheld LCR Meter, 40,000-count, 0.1%

Customer Reviews for the B&K 880

More B&K Products

Calibration Lab