A complete and convenient portable power metering solution for load studies and energy audits, this kit includes the line-powered ELITEpro XC of your choice, plus quick-to-install flexible RoCoil CTs that measure from 0.5 right up to 6500A.

A complete and convenient portable power metering solution for load studies and energy audits, this kit includes the line-powered ELITEpro XC of your choice, plus quick-to-install flexible RoCoil CTs that measure from 0.5 right up to 6500A.

Dent ELITEpro XC Bundle

Choose your meter

Choose your CTs

Clear selected options



Dent XC-KIT Offers

A dependable and versatile tool for measuring energy usage

The ELITEpro XC is a complete solution for pinpointing electric usage and quantifying energy usage. It is capable of measuring, storing, and analyzing electrical consumption data which is derived from the voltage and current inputs. The ELITEpro XC uses direct connections to each phase of the voltage and various interchangeable CT options such as split-core current transformers or flexible RoCoils™ (for large loads or large cables and bussbars) to monitor current on each phase.

These meters can capture kWh/kW energy and demand data as well as virtually all relevant energy parameters for diagnostics and monitoring on three-phase or single-phase circuit installations. Electrical load diagnostic parameters, such as displacement power factor, are captured in addition to energy and demand values.

The ELITEpro XC's flexibility, size, and ease-of-use make it the ideal tool for gathering detailed consumption information in commercial, industrial, government and retail environments.

Four Analog Input Channels: Correlate your consumption with environmental conditions.

New to the ELITEpro XC are 4 analog input channels which can be configured for voltage or current input used in any combination among channels. Analog inputs are especially helpful when used in conjunction with power measurements to correlate the consumption of electricity with environmental, HVAC/R plant performance, or other process conditions. Typical uses might include logging ambient temperature, building temperatures, solar insolation, tank pressures, duct flows, etc. Obtain this valuable data using just one meter: the ELITEpro XC.

Features

  • For single or 3-phase systems using 80-600V phase-to-phase (AC or DC) services when line powered or 0-600V (AC or DC) when externally powered. Measures up to four channels of energy metrics with currents ranging from 0-6,000 amps.
  • Analog Inputs record analog data with configurable input ranges for voltage (0-15 VDC) or current loop (0 or 4-20 mA) transducers. Analog inputs are used for process or environmental correlation studies with power.
  • Line-powered - no need for batteries or external power source.
  • User-selectable recording intervals as short as every 1 second
  • 16 MB non-volatile memory standard for months of recording time.
  • Better than 1% accuracy (<0.2% typical).
  • Fast USB connection and standard Ethernet port.
  • ELITEpro XC may be configured with optional Bluetooth® wireless technology.
  • Optional Wi-Fi interface allows for remote data collection over wireless networks. Check real-time values using a Wi-Fi-enabled laptop, tablet, or smartphone via a web browser.
  • Simple yet powerful Windows-based ELOG™ software package for setup, data retrieval, and analysis. Easy data exporting to almost any analysis program.
  • Easy to setup and installs in minutes. Patented PhaseChek™ LED indicators ensure correct CT orientation at installation.
  • Rugged and compact-easily fits inside breaker panels and switch gear.
  • PhaseChek™: PhaseChek lights verify that that the CTs are correctly installed - green is good, red means that either a CT is incorrectly installed or that a CT is in the wrong orientation.
  • Mount Inside or Beside: Mount the ELITEpro XC inside the panel using the mounting magnets or beside the panel using the mounting tab
  • Log with Confidence: Indicator lights show that the meter is recording
  • Standard Ethernet Port: The Ethernet and USB ports are standard equipment, no additional costs
  • Line Powered with Reduced Impact on Environment
  • Memory for Extended Recording
  • Bi-Directional Metering for Renewable Studies
  • Fast Sampling Rate Captures Power Quality Data
  • Field-Proven: Rugged & Compact

Applications

  • Measurement and Verification (M&V) Studies
  • Electrical Load Profiling
  • Energy Audits
  • New Technology Assessment Studies
  • Weatherproof Enclosures

Connections

  • Voltage: Connections via fused or unfused crocodile clips or shark clips
  • Current: Use up to four channels of current via CTs connected to a terminal block
  • Power: Power is supplied via the voltage connections - no auxillary supply is required

Communications Options

  • Ethernet & USB - The Ethernet and USB ports are standard equipment
    Connect with USB - Connect directly to the ELITEpro XC via the included A-to-B USB cable.
    Connect with Ethernet - Connect remotely to the logger via 10/100MB Ethernet using DHCP or static IP to manually or automatically download data or reconfigure.

  • WiFi - Use optional WiFi to setup, record and view data remotely
    Connect with Wifi - The optional Wi-Fi interface allows the meter to be connected to a Wi-Fi network and accessed from any PC on the network using ELOG software. Alternatively, configure the ELITEpro XC as its own Wi-Fi hotspot and view real-time data using a Wi-Fi enabled PC, tablet, or smart phone via a web browser from up to 300 ft. away.

  • WiFi with Antenna - Optional WiFi with external antenna provides 3dbi gain
    Connect to Wifi with Antenna - Two antenna options are available: internal antenna (75-300 ft.) or external 3 dbi antenna (150-300 ft). Use ELOG to switch between WiFi and QuickView™ access point mode

  • Bluetooth - Optional Bluetooth provides short-range wireless configuration
    Connect with BlueTooth® - Save time and meet safety requirements by communicating with an ELITEpro XC without removing the electrical panel door. In addition to the standard USB and Ethernet ports, ELITEpro XC instruments may be equipped with an optional Bluetooth® wireless technology interface, which will allow a PC with a Bluetooth® wireless technology adapter running ELOG to connect to the ELITEpro XC over short distances (10-100 feet typical) to send setup tables or download data. PC must support Serial Port Profile (SPP)

Current Transformers

An Industry-Leading Selection of Quality Transformers

Choose from an interchangeable selection of CT options including split-core, clamp-on, hinged and flexible RoCoil™ types. The ELITEpro XC comes with an embedded Rogowski coil CT amplifier/integrator circuit so there is no need to provide external power when using our line of flexible RoCoil™ CTs.

All DENT CTs are internally shunted for intrinsically safe operation on energized conductors. Special high-accuracy CTs are available for existing CT secondary monitoring. The ELITEpro XC can monitor up to four single-phase loads, two three-phase (3-wire) Delta loads or one three-phase (4-wire) WYE load.


Case Study - ELITEpro XC: A Key Tool for Auditing Compressed Air Systems

Dent XC-KIT Specifications

Software

Setup, download & analyze

ELOG software is used to program the meter, display metered values, and retrieve and analyze the collected data.

ELOG graphically displays recorded data, performs analysis, and facilitates automatic remote data collection. Data is also easily exported to popular spreadsheet and database programs for additional analysis.

You are provided with an unlimited site license to the software with purchase.


Specifications

Technical
Service Type Single Phase (two wire or three wire), Three Phase-Four Wire (WYE), Three Phase-Three Wire (Delta), DC Systems (Solar/Battery)
Voltage Channels 3 channels, CAT III, 0-600 VAC (line-to-line) or 600 VDC
Current Channels 4 channels, .67 VAC max, ± 1 VDC. Ideal for 333 mV full scale CTs
Maximum Current Input External transducer dependent. 200% of current transducer rating (mV CTs) Measure up to 6000A with RoCoil CTs.
Measurement Type True RMS using high-speed digital signal processing (DSP)
Line Frequency DC/50/60/400 Hz*
Waveform Sampling 12 kHz
Channel Sampling Rate .125 seconds
Integration Period 1, 3, 15, 30 seconds; 1, 2, 5, 10, 15, 20, and 30 minutes; 1 and 12 hours, 1 day
Energy Measurements Volts, Amps, Amp-Hrs (Ah), kW, kWh, kVAR, kVARh, kVA, kVAh, Displacement Power Factor (dPF). All parameters for each phase and for system total.
Analog Measurements 0-10 Volts, 0 or 4-20 mA current loop. Non-isolated, external power for current loop. User scaling for sensor reporting in physical units.
Accuracy Better than 1% (<0.2% typical) for V, A, kW, kVAR, kVA, PF, Analog
Resolution 0.01 Amp, 0.1 Volt, 1 Watt, 1 VAR, 1 VA, 0.01 PF, 0.01 ANA
LED Indicators Tri-color (red, green, blue): 1 LED indicates communication (blue for wireless, Bluetooth® or Ethernet), 4 LEDs for correct phasing (PhaseChek™).
Power
Line-Power From L1 Phase to L2 Phase. 80-600V (AC or DC) CAT III DC/50/60/400 Hz, 125 mA, 5 W, or 10 VA max. Non-user replaceable .5 Amp internal fuse protection.
Power In 6-10 VDC, 500 mA
Power Out 6 VDC, 200 mA max
Communications
USB (Standard) USB standard (Type B). 1.8 M (6 ft) A-to-B USB Cable (included)
Ethernet (Standard) Standard RJ-45 Connector supports 10/100 MB Ethernet over Cat 5 or better. Configure for DHCP or Static IP.
Bluetooth Wireless Technology (Optional) Internal antenna with 10-100 ft range (typical). Requires Bluetooth® wireless technology adapter on Windows PC. Adapter must support the Serial Port Profile (SPP).
Wi-Fi Adapter† (optional) Wi-Fi option available as two separate configurations:
  • Internal antenna: typical range 75-300 ft.
  • External 3 dbi antenna: typical range 150-300 ft.
Mechanical
Operating Temperature -7 to + 60 °C (20 to 140 °F)
Operating Humidity 5% to 95% non-condensing
Enclosure Type ABS plastic, 94-V0 flammability rating
Weight 340 g (12 ounces)
Dimensions 21.6 x 6.3 x 4.7 cm (8.5" x 2.5" x 1.9")

* Performance varies at 400 Hz operation. Contact the factory for details.
† ELITEpro XC loggers that are equipped with a Wi-Fi package contain an internal antenna. An external antenna is optional. You may toggle between using the internal and external antenna (if it is available on your logger) by checking or unchecking the Use External Antenna checkbox in ELOG.
US/NORTH AMERICAN ELITEpro XC configuration includes 4 color (black, blue, red, white) voltage leads and croc clips. INTERNATIONAL ELITEpro XC configuration includes 3 black voltage lead connections, 1 white connection (neutral) and 5 color (black, blue, red, white, yellow) voltage leads and croc clips.

Click here for complete specifications on the Dent XC-KIT

What's included with the Dent XC-KIT

  • Dent ElitePro XC Portable Power Metering Datalogger Kit

Ask a question about Dent ElitePro XC Portable Power Metering Datalogger Kit

Customer Reviews for the Dent XC-KIT

Dent XC-KIT Offers

A dependable and versatile tool for measuring energy usage

The ELITEpro XC is a complete solution for pinpointing electric usage and quantifying energy usage. It is capable of measuring, storing, and analyzing electrical consumption data which is derived from the voltage and current inputs. The ELITEpro XC uses direct connections to each phase of the voltage and various interchangeable CT options such as split-core current transformers or flexible RoCoils™ (for large loads or large cables and bussbars) to monitor current on each phase.

These meters can capture kWh/kW energy and demand data as well as virtually all relevant energy parameters for diagnostics and monitoring on three-phase or single-phase circuit installations. Electrical load diagnostic parameters, such as displacement power factor, are captured in addition to energy and demand values.

The ELITEpro XC's flexibility, size, and ease-of-use make it the ideal tool for gathering detailed consumption information in commercial, industrial, government and retail environments.

Four Analog Input Channels: Correlate your consumption with environmental conditions.

New to the ELITEpro XC are 4 analog input channels which can be configured for voltage or current input used in any combination among channels. Analog inputs are especially helpful when used in conjunction with power measurements to correlate the consumption of electricity with environmental, HVAC/R plant performance, or other process conditions. Typical uses might include logging ambient temperature, building temperatures, solar insolation, tank pressures, duct flows, etc. Obtain this valuable data using just one meter: the ELITEpro XC.

Features

  • For single or 3-phase systems using 80-600V phase-to-phase (AC or DC) services when line powered or 0-600V (AC or DC) when externally powered. Measures up to four channels of energy metrics with currents ranging from 0-6,000 amps.
  • Analog Inputs record analog data with configurable input ranges for voltage (0-15 VDC) or current loop (0 or 4-20 mA) transducers. Analog inputs are used for process or environmental correlation studies with power.
  • Line-powered - no need for batteries or external power source.
  • User-selectable recording intervals as short as every 1 second
  • 16 MB non-volatile memory standard for months of recording time.
  • Better than 1% accuracy (<0.2% typical).
  • Fast USB connection and standard Ethernet port.
  • ELITEpro XC may be configured with optional Bluetooth® wireless technology.
  • Optional Wi-Fi interface allows for remote data collection over wireless networks. Check real-time values using a Wi-Fi-enabled laptop, tablet, or smartphone via a web browser.
  • Simple yet powerful Windows-based ELOG™ software package for setup, data retrieval, and analysis. Easy data exporting to almost any analysis program.
  • Easy to setup and installs in minutes. Patented PhaseChek™ LED indicators ensure correct CT orientation at installation.
  • Rugged and compact-easily fits inside breaker panels and switch gear.
  • PhaseChek™: PhaseChek lights verify that that the CTs are correctly installed - green is good, red means that either a CT is incorrectly installed or that a CT is in the wrong orientation.
  • Mount Inside or Beside: Mount the ELITEpro XC inside the panel using the mounting magnets or beside the panel using the mounting tab
  • Log with Confidence: Indicator lights show that the meter is recording
  • Standard Ethernet Port: The Ethernet and USB ports are standard equipment, no additional costs
  • Line Powered with Reduced Impact on Environment
  • Memory for Extended Recording
  • Bi-Directional Metering for Renewable Studies
  • Fast Sampling Rate Captures Power Quality Data
  • Field-Proven: Rugged & Compact

Applications

  • Measurement and Verification (M&V) Studies
  • Electrical Load Profiling
  • Energy Audits
  • New Technology Assessment Studies
  • Weatherproof Enclosures

Connections

  • Voltage: Connections via fused or unfused crocodile clips or shark clips
  • Current: Use up to four channels of current via CTs connected to a terminal block
  • Power: Power is supplied via the voltage connections - no auxillary supply is required

Communications Options

  • Ethernet & USB - The Ethernet and USB ports are standard equipment
    Connect with USB - Connect directly to the ELITEpro XC via the included A-to-B USB cable.
    Connect with Ethernet - Connect remotely to the logger via 10/100MB Ethernet using DHCP or static IP to manually or automatically download data or reconfigure.

  • WiFi - Use optional WiFi to setup, record and view data remotely
    Connect with Wifi - The optional Wi-Fi interface allows the meter to be connected to a Wi-Fi network and accessed from any PC on the network using ELOG software. Alternatively, configure the ELITEpro XC as its own Wi-Fi hotspot and view real-time data using a Wi-Fi enabled PC, tablet, or smart phone via a web browser from up to 300 ft. away.

  • WiFi with Antenna - Optional WiFi with external antenna provides 3dbi gain
    Connect to Wifi with Antenna - Two antenna options are available: internal antenna (75-300 ft.) or external 3 dbi antenna (150-300 ft). Use ELOG to switch between WiFi and QuickView™ access point mode

  • Bluetooth - Optional Bluetooth provides short-range wireless configuration
    Connect with BlueTooth® - Save time and meet safety requirements by communicating with an ELITEpro XC without removing the electrical panel door. In addition to the standard USB and Ethernet ports, ELITEpro XC instruments may be equipped with an optional Bluetooth® wireless technology interface, which will allow a PC with a Bluetooth® wireless technology adapter running ELOG to connect to the ELITEpro XC over short distances (10-100 feet typical) to send setup tables or download data. PC must support Serial Port Profile (SPP)

Current Transformers

An Industry-Leading Selection of Quality Transformers

Choose from an interchangeable selection of CT options including split-core, clamp-on, hinged and flexible RoCoil™ types. The ELITEpro XC comes with an embedded Rogowski coil CT amplifier/integrator circuit so there is no need to provide external power when using our line of flexible RoCoil™ CTs.

All DENT CTs are internally shunted for intrinsically safe operation on energized conductors. Special high-accuracy CTs are available for existing CT secondary monitoring. The ELITEpro XC can monitor up to four single-phase loads, two three-phase (3-wire) Delta loads or one three-phase (4-wire) WYE load.


Case Study - ELITEpro XC: A Key Tool for Auditing Compressed Air Systems

Dent XC-KIT Specifications

Software

Setup, download & analyze

ELOG software is used to program the meter, display metered values, and retrieve and analyze the collected data.

ELOG graphically displays recorded data, performs analysis, and facilitates automatic remote data collection. Data is also easily exported to popular spreadsheet and database programs for additional analysis.

You are provided with an unlimited site license to the software with purchase.


Specifications

Technical
Service Type Single Phase (two wire or three wire), Three Phase-Four Wire (WYE), Three Phase-Three Wire (Delta), DC Systems (Solar/Battery)
Voltage Channels 3 channels, CAT III, 0-600 VAC (line-to-line) or 600 VDC
Current Channels 4 channels, .67 VAC max, ± 1 VDC. Ideal for 333 mV full scale CTs
Maximum Current Input External transducer dependent. 200% of current transducer rating (mV CTs) Measure up to 6000A with RoCoil CTs.
Measurement Type True RMS using high-speed digital signal processing (DSP)
Line Frequency DC/50/60/400 Hz*
Waveform Sampling 12 kHz
Channel Sampling Rate .125 seconds
Integration Period 1, 3, 15, 30 seconds; 1, 2, 5, 10, 15, 20, and 30 minutes; 1 and 12 hours, 1 day
Energy Measurements Volts, Amps, Amp-Hrs (Ah), kW, kWh, kVAR, kVARh, kVA, kVAh, Displacement Power Factor (dPF). All parameters for each phase and for system total.
Analog Measurements 0-10 Volts, 0 or 4-20 mA current loop. Non-isolated, external power for current loop. User scaling for sensor reporting in physical units.
Accuracy Better than 1% (<0.2% typical) for V, A, kW, kVAR, kVA, PF, Analog
Resolution 0.01 Amp, 0.1 Volt, 1 Watt, 1 VAR, 1 VA, 0.01 PF, 0.01 ANA
LED Indicators Tri-color (red, green, blue): 1 LED indicates communication (blue for wireless, Bluetooth® or Ethernet), 4 LEDs for correct phasing (PhaseChek™).
Power
Line-Power From L1 Phase to L2 Phase. 80-600V (AC or DC) CAT III DC/50/60/400 Hz, 125 mA, 5 W, or 10 VA max. Non-user replaceable .5 Amp internal fuse protection.
Power In 6-10 VDC, 500 mA
Power Out 6 VDC, 200 mA max
Communications
USB (Standard) USB standard (Type B). 1.8 M (6 ft) A-to-B USB Cable (included)
Ethernet (Standard) Standard RJ-45 Connector supports 10/100 MB Ethernet over Cat 5 or better. Configure for DHCP or Static IP.
Bluetooth Wireless Technology (Optional) Internal antenna with 10-100 ft range (typical). Requires Bluetooth® wireless technology adapter on Windows PC. Adapter must support the Serial Port Profile (SPP).
Wi-Fi Adapter† (optional) Wi-Fi option available as two separate configurations:
  • Internal antenna: typical range 75-300 ft.
  • External 3 dbi antenna: typical range 150-300 ft.
Mechanical
Operating Temperature -7 to + 60 °C (20 to 140 °F)
Operating Humidity 5% to 95% non-condensing
Enclosure Type ABS plastic, 94-V0 flammability rating
Weight 340 g (12 ounces)
Dimensions 21.6 x 6.3 x 4.7 cm (8.5" x 2.5" x 1.9")

* Performance varies at 400 Hz operation. Contact the factory for details.
† ELITEpro XC loggers that are equipped with a Wi-Fi package contain an internal antenna. An external antenna is optional. You may toggle between using the internal and external antenna (if it is available on your logger) by checking or unchecking the Use External Antenna checkbox in ELOG.
US/NORTH AMERICAN ELITEpro XC configuration includes 4 color (black, blue, red, white) voltage leads and croc clips. INTERNATIONAL ELITEpro XC configuration includes 3 black voltage lead connections, 1 white connection (neutral) and 5 color (black, blue, red, white, yellow) voltage leads and croc clips.

Click here for complete specifications on the Dent XC-KIT

What's included with the Dent XC-KIT

  • Dent ElitePro XC Portable Power Metering Datalogger Kit

Ask a question about Dent ElitePro XC Portable Power Metering Datalogger Kit

Customer Reviews for the Dent XC-KIT

More Dent Products

Calibration Lab