Voltage | Range: 90 to 600 Vrms CAT III Accuracy: 90 to 600 Vrms = ±0.1%, <90 Vrms = 0.5% Connections: 4 safety banana voltage inputs - 3 phase voltage and 1 neutral/reference |
Current | Input: 0.333 Vrms full scale, Connections: BNC Accuracy: ±0.1% + probe |
Frequency | Range: 50 Hz = 45 to 55 Hz, 60 Hz = 55 to 65 Hz Accuracy: 50/60 Hz: ±0.001 Hz |
Power Quality | Sag/dip, swell trigger threshold resolution: 1 cycle Vthd: ±5% for V ≥ 10% Vnom Ithd: ±5% for I ≥ 10% Inom + probe error |
Power | Line power supply Range: 90 to 264 VAC, 47 to 63 Hz, Consumption: 15 W maximum Line cords/plugs: Localized Internal battery Rechargeable lithium Ion battery pack (UL recognized) Run time: 7 hours (typical), Charge time: 15 hours (typical) |
Communication | Ethernet: 10 USB: 2.0 Protocols: Modbus, Bacnet |
Operating Temperature | 32 to 113°F (0 to 45°C) |
Storage Temperature | 5 to 131°F (-15 to 55°C) |
Humidity | 5 to 95% non-condensing |
Ingress Protection | IP50 (vertical position) |
Dimensions | 3.5 x 2.2 x 7.4" (6.4 x 8.9 x 18.8 cm) |
Weight | 1.4 lbs (0.64 kg) |
Click on a category to view a selection of compatible accessories with the Dranetz DranXperT Portable Power Logger and Power Quality Detector Kit with 500 A Flex CT's, 24".
Voltage | Range: 90 to 600 Vrms CAT III Accuracy: 90 to 600 Vrms = ±0.1%, <90 Vrms = 0.5% Connections: 4 safety banana voltage inputs - 3 phase voltage and 1 neutral/reference |
Current | Input: 0.333 Vrms full scale, Connections: BNC Accuracy: ±0.1% + probe |
Frequency | Range: 50 Hz = 45 to 55 Hz, 60 Hz = 55 to 65 Hz Accuracy: 50/60 Hz: ±0.001 Hz |
Power Quality | Sag/dip, swell trigger threshold resolution: 1 cycle Vthd: ±5% for V ≥ 10% Vnom Ithd: ±5% for I ≥ 10% Inom + probe error |
Power | Line power supply Range: 90 to 264 VAC, 47 to 63 Hz, Consumption: 15 W maximum Line cords/plugs: Localized Internal battery Rechargeable lithium Ion battery pack (UL recognized) Run time: 7 hours (typical), Charge time: 15 hours (typical) |
Communication | Ethernet: 10 USB: 2.0 Protocols: Modbus, Bacnet |
Operating Temperature | 32 to 113°F (0 to 45°C) |
Storage Temperature | 5 to 131°F (-15 to 55°C) |
Humidity | 5 to 95% non-condensing |
Ingress Protection | IP50 (vertical position) |
Dimensions | 3.5 x 2.2 x 7.4" (6.4 x 8.9 x 18.8 cm) |
Weight | 1.4 lbs (0.64 kg) |
Click on a category to view a selection of compatible accessories with the Dranetz DranXperT Portable Power Logger and Power Quality Detector Kit with 500 A Flex CT's, 24".