FREE SHIPPING ON ONLINE ORDERS OVER $99*

Dwyer 2001 Magnehelic Differential Pressure Gauge (0-1.0"w.c.)

Model: 2001 | UPC: 461021015822

Dwyer 2001 Magnehelic Differential Pressure Gauge (0-1.0"w.c.)-

Image is for reference only, refer to product info for complete details.


Downloads: datasheet manual

Dwyer 2001 Magnehelic Differential Pressure Gauge (0-1.0"w.c.)

Model: 2001 | UPC: 461021015822

Bezel provides flange for flush mounting in panel. Clear plastic face is highly resistant to breakage. Provides undistorted viewing of pointer and scale.

Bezel provides flange for flush mounting in panel. Clear plastic face is highly resistant to breakage. Provides undistorted viewing of pointer and scale.

Sale Price $70.45 USD
Regular Price $75.35 USD
Availability 1 in Stock
Quantity

Traceable In-House Calibration Certificate for your Dwyer 2001 Magnehelic Differential Pressure Gauge (0-1.0"w.c.)

Traceable In-House Calibration Certificate for your Dwyer 2001 Magnehelic Differential Pressure Gauge (0-1.0"w.c.)

Dwyer 2001 Magnehelic Differential Pressure Gauge range 0-1.0

The Dwyer 2001 Differential Pressure Gauge Features a range of 0-1.0" w.c. and minor divisions of .02.

Select the Magnehelic® gauge for high accuracy--guaranteed within 2% of full scale--and for the wide choice of 81 models available to suit your needs precisely. Using Dwyer's simple, frictionless Magnehelic® gauge movement, it quickly indicates low air or non-corrosive gas pressures--either positive, negative (vacuum) or differential. The design resists shock, vibration and over-pressures. No manometer fluid to evaporate, freeze or cause toxic or leveling problems. It's inexpensive, too.

The Magnehelic® gauge is the industry standard to measure fan and blower pressures, filter resistance, air velocity, furnace draft, pressure drop across orifice plates, liquid levels with bubbler systems and pressures in fluid amplifier or fluidic systems. It also checks gas-air ratio controls and automatic valves, and monitors blood and respiratory pressures in medical care equipment.

Note: May be used with Hydrogen. Order a Buna-N diaphragm. Pressures must be less than 35 psi.

Dwyer 2001 Specifications

Service Air and non-combustible, compatible gases
May be used with hydrogen
Pressures must be less than 35 psi
Housing Die cast aluminum case and bezel, with acrylic cover
Exterior finish is coated gray to withstand 168 hour salt spray corrosion test
Accuracy ±2% (-HA model ±1) of FS (±3% (-HA ±1.5%) on -0, -100 PA, -125 PA, -10 MM
±4% (-HA ±2%) on -00, -60PA, -6MM ranges), throughout range at 70°F (21.1°C)
Pressure Limits -20 in Hg. to 15 psig.† (-0.677 bar to 1.034 bar)
MP option: 35 psig (2.41 bar), HP option: 80 psig (5.52 bar)
Enclosure Rating IP67
Overpressure Relief plug opens at approximately 25 psig (1.72 bar), standard gages only
Temperature Limits 20 to 140°F (-6.67 to 60°C)
-20°F (-28°C) with low temperature option
Mounting Orientation Diaphragm in vertical position
Process Connections ⅛" emale NPT duplicate high and low pressure taps - one pair side and one pair back
Dimensions 4" (101.6 mm) diameter dial face
Click here for complete specifications on the Dwyer 2001

What's included with the Dwyer 2001

  • Dwyer 2001 Magnehelic Differential Pressure Gauge (0-1.0"w.c.)

Click on a category to view a selection of compatible accessories with the Dwyer 2001 Magnehelic Differential Pressure Gauge (0-1.0"w.c.).

Dwyer 160-12 Stainless Steel Pitot Tube (5/16" dia. X 12"L) 160-12
No calibration needed. Precisely located, burr-free static pressure holes.




Dwyer A-610 Pipe Mounting Kit for 1-1/4" to 2" pipes A-610
Allows Magnehelic® to be conveniently installed on horizontal or vertical 1 1/4" to 2" pipe.




Dwyer A-371 Surface Mounting Bracket for Photohelic Gauges A-371
Surface mounting bracket for Photohelic and Capsu-Photohelic.





Dwyer A-369 Stand-Hang Aluminum Bracket for Magnehelic Gauges A-369
Aluminum stand-hang bracket for Dwyer Magnehelic® gauges.




Dwyer A-605 Air Filter Kit for use with Magnehelic Gauges A-605
Adapts any standard Magnehelic® for use as an air filter gauge. Includes aluminum surface mounting bracket with screws, two 5 ft. lengths of 1/4" aluminum tubing, two static pressure tips and two molded plastic vent valves, integral compression fittings on both tips and valves.




Dwyer A-432 Molded Plastic Carrying Case for Magnehelic gauges A-432
Gray, high-density polyethylene molded carrying case for use with Magnehelic gauges. It comes equipped with 9' (2.7 m) of 3/16" ID rubber tubing, stand-hang bracket, and terminal tube with holder.












Dwyer A-303 Static Pressure Tip for 3/16" ID Plastic or Rubber Tubing with 4" insertion A-303
Sense static pressure drop across air filters, coils, fan discharge pressures, etc. For portable use, a magnet holds unit in place.




Dwyer A-302 Static Pressure Tip for 3/16" & 1/8" ID Plastic or Rubber Tubing A-302
Sense static pressure drop across air filters, coils, fan discharge pressures, etc.




Dwyer A-301 Static Pressure Tip for 1/4" Metal Tubing Connection A-301
Sense static pressure drop across air filters, coils, fan discharge pressures, etc.




Ask a question about Dwyer 2001 Magnehelic Differential Pressure Gauge (0-1.0"w.c.)

Customer Reviews for the Dwyer 2001

Dwyer 2001 Magnehelic Differential Pressure Gauge range 0-1.0

The Dwyer 2001 Differential Pressure Gauge Features a range of 0-1.0" w.c. and minor divisions of .02.

Select the Magnehelic® gauge for high accuracy--guaranteed within 2% of full scale--and for the wide choice of 81 models available to suit your needs precisely. Using Dwyer's simple, frictionless Magnehelic® gauge movement, it quickly indicates low air or non-corrosive gas pressures--either positive, negative (vacuum) or differential. The design resists shock, vibration and over-pressures. No manometer fluid to evaporate, freeze or cause toxic or leveling problems. It's inexpensive, too.

The Magnehelic® gauge is the industry standard to measure fan and blower pressures, filter resistance, air velocity, furnace draft, pressure drop across orifice plates, liquid levels with bubbler systems and pressures in fluid amplifier or fluidic systems. It also checks gas-air ratio controls and automatic valves, and monitors blood and respiratory pressures in medical care equipment.

Note: May be used with Hydrogen. Order a Buna-N diaphragm. Pressures must be less than 35 psi.

Dwyer 2001 Specifications

Service Air and non-combustible, compatible gases
May be used with hydrogen
Pressures must be less than 35 psi
Housing Die cast aluminum case and bezel, with acrylic cover
Exterior finish is coated gray to withstand 168 hour salt spray corrosion test
Accuracy ±2% (-HA model ±1) of FS (±3% (-HA ±1.5%) on -0, -100 PA, -125 PA, -10 MM
±4% (-HA ±2%) on -00, -60PA, -6MM ranges), throughout range at 70°F (21.1°C)
Pressure Limits -20 in Hg. to 15 psig.† (-0.677 bar to 1.034 bar)
MP option: 35 psig (2.41 bar), HP option: 80 psig (5.52 bar)
Enclosure Rating IP67
Overpressure Relief plug opens at approximately 25 psig (1.72 bar), standard gages only
Temperature Limits 20 to 140°F (-6.67 to 60°C)
-20°F (-28°C) with low temperature option
Mounting Orientation Diaphragm in vertical position
Process Connections ⅛" emale NPT duplicate high and low pressure taps - one pair side and one pair back
Dimensions 4" (101.6 mm) diameter dial face
Click here for complete specifications on the Dwyer 2001

What's included with the Dwyer 2001

  • Dwyer 2001 Magnehelic Differential Pressure Gauge (0-1.0"w.c.)

Click on a category to view a selection of compatible accessories with the Dwyer 2001 Magnehelic Differential Pressure Gauge (0-1.0"w.c.).

Dwyer 160-12 Stainless Steel Pitot Tube (5/16" dia. X 12"L) 160-12
No calibration needed. Precisely located, burr-free static pressure holes.




Dwyer A-610 Pipe Mounting Kit for 1-1/4" to 2" pipes A-610
Allows Magnehelic® to be conveniently installed on horizontal or vertical 1 1/4" to 2" pipe.




Dwyer A-371 Surface Mounting Bracket for Photohelic Gauges A-371
Surface mounting bracket for Photohelic and Capsu-Photohelic.





Dwyer A-369 Stand-Hang Aluminum Bracket for Magnehelic Gauges A-369
Aluminum stand-hang bracket for Dwyer Magnehelic® gauges.




Dwyer A-605 Air Filter Kit for use with Magnehelic Gauges A-605
Adapts any standard Magnehelic® for use as an air filter gauge. Includes aluminum surface mounting bracket with screws, two 5 ft. lengths of 1/4" aluminum tubing, two static pressure tips and two molded plastic vent valves, integral compression fittings on both tips and valves.




Dwyer A-432 Molded Plastic Carrying Case for Magnehelic gauges A-432
Gray, high-density polyethylene molded carrying case for use with Magnehelic gauges. It comes equipped with 9' (2.7 m) of 3/16" ID rubber tubing, stand-hang bracket, and terminal tube with holder.












Dwyer A-303 Static Pressure Tip for 3/16" ID Plastic or Rubber Tubing with 4" insertion A-303
Sense static pressure drop across air filters, coils, fan discharge pressures, etc. For portable use, a magnet holds unit in place.




Dwyer A-302 Static Pressure Tip for 3/16" & 1/8" ID Plastic or Rubber Tubing A-302
Sense static pressure drop across air filters, coils, fan discharge pressures, etc.




Dwyer A-301 Static Pressure Tip for 1/4" Metal Tubing Connection A-301
Sense static pressure drop across air filters, coils, fan discharge pressures, etc.




Ask a question about Dwyer 2001 Magnehelic Differential Pressure Gauge (0-1.0"w.c.)

Customer Reviews for the Dwyer 2001

More Dwyer Products

Calibration Lab