FREE SHIPPING ON ONLINE ORDERS OVER $99*

Dwyer IEF Insertion Electromagnetic Flow Transmitter with LCD display, PG 16 gland with 10' cable

Model: IEF-HN-10-LCD

Dwyer IEF Insertion Electromagnetic Flow Transmitter with LCD display, PG 16 gland with 10' cable

Model: IEF-HN-10-LCD

An adjustable insertion flowmeter featuring electromagnetic technology to accurately and reliably measure fluid velocity, and provides several continuous signal outputs. Offers a high accuracy of 1% of reading, and comes equipped with LCD display, and PG 16 gland with two 10' (3 m) plenum rated cables.

An adjustable insertion flowmeter featuring electromagnetic technology to accurately and reliably measure fluid velocity, and provides several continuous signal outputs. Offers a high accuracy of 1% of reading, and comes equipped with LCD display, and PG 16 gland with two 10' (3 m) plenum rated cables.

Sale Price $4458.08 USD
Regular Price $4768.00 USD
Availability 2 to 3 Weeks
Quantity

Dwyer IEF-HN-10-LCD Offers

Features

  • Field configurable, integral or remote setup displays allow for ultimate flexibility by accommodating a variety of application configurations with one model through multiple display configurations i.e. pipe size, pipe material, liquid type, analog output, pulse/frequency output, alarm outputs, communication outputs, damping, and calibration factor
  • High performance accuracy is maintained through changes in temperature, density or viscosity
  • Setup Wizard and installation tool are simple to use allowing for quick and precise installation
  • Accessory setup kit A-IEF-KIT (sold separately) ensures exact installation application depth with included thickness gauge and measuring tape
  • Long Life Cycle and minimal maintenance requirements with no moving parts to wear or break and electrodes that discourage fouling
  • Isolation valve accessory options (sold separately) allow for installation in operational systems via hot-tap kit or easy removal without system downtime

Applications

  • Boiler feed water
  • Chilled water
  • Open and closed loop condenser water
  • Irrigation system
  • Municipal water distribution
  • Process and coolant flow
  • Ground water remediation
  • Chemical processing
  • Pump protection
  • Wastewater
  • Mining

Dwyer IEF-HN-10-LCD Specifications

Service Compatible clean or dirty non coating, conductive liquids
Range 0 to 20 ft/s (0 to 6 m/s)
Wetted Materials Body shaft/fitting: 316 SS
Electrodes: 316 SS
Electrode cap: Polymer/Polystyrene
O-ring: Silicon
Accuracy ±0.5% of reading at calibrated velocity; ±1% of reading from 2 to 20 ft/s (0.6 to 6 m/s); ±0.02 ft/s (±0.006 m/s) at <2 ft/s (0.6 m/s)
Temperature Limits Ambient: -20 to 160°F (-29 to 71°C)
Process: 15 to 250°F (-9 to 121°C)
Storage: -40 to 185°F (-40 to 85°C)
Process Connection 1" NPT
Pressure Limits: 400 psi (27.6 bar) @ 100°F (37.8°C)
Drop: <0.1 psi at 12 ft/s in 4" (101.6 mm) and larger pipe
Outputs (1) Analog: 4 to 20 mA, 0 to 5 V, 0 to 10 V or 2 to 10 V (display selectable)
(1) Pulse/Frequency: 0 to 15 V peak pulse, 0 to 500 Hz or scalable pulse output (display selectable)
(2) Alarm: (1) Empty pipe detection or minimum/maximum velocity, (display selectable)
(1) Reverse flow output indication
Power Requirements 12 to 42.4 VDC, 0.25 A @ 24 VDC; 12 to 36 VAC
Display 2 x 2" (5.08 x 5.08 cm) graphic LCD with backlight
Conductivity >20 microsiemens
Enclosure Material: Powder coated die cast aluminum
Ratings: NEMA 4X (IP66)
Agency Approvals BTL, CE, NSF/ANSI 61 and 372
Click here for complete specifications on the Dwyer IEF-HN-10-LCD

What's included with the Dwyer IEF-HN-10-LCD

  • Dwyer IEF Insertion Electromagnetic Flow Transmitter with LCD display, PG 16 gland with 10' cable

Click on a category to view a selection of compatible accessories with the Dwyer IEF Insertion Electromagnetic Flow Transmitter with LCD display, PG 16 gland with 10' cable.

Dwyer A-IEF-KIT Setup Kit for the IEF series A-IEF-KIT
For use with IEF Insertion Electromagnetic Flow Transmitters.




Dwyer A-IEF-INGD Installation Guide/Alignment Kit for the IEF Series A-IEF-INGD
For use with IEF Insertion Electromagnetic Flow Transmitters.




Dwyer A-IEF-LID Replacement Blank Lid for the IEF series A-IEF-LID
For use with IEF Insertion Electromagnetic Flow Transmitters.




Dwyer A-IEF-VLV-SS Full Port Isolation Valve for the IEF series, 1¼", 316SS A-IEF-VLV-SS
A 1¼ 316SS full port isolation vavle for use with IEF Insertion Electromagnetic Flow Transmitters.




Ask a question about Dwyer IEF Insertion Electromagnetic Flow Transmitter with LCD display, PG 16 gland with 10' cable

Customer Reviews for the Dwyer IEF-HN-10-LCD

Dwyer IEF-HN-10-LCD Offers

Features

  • Field configurable, integral or remote setup displays allow for ultimate flexibility by accommodating a variety of application configurations with one model through multiple display configurations i.e. pipe size, pipe material, liquid type, analog output, pulse/frequency output, alarm outputs, communication outputs, damping, and calibration factor
  • High performance accuracy is maintained through changes in temperature, density or viscosity
  • Setup Wizard and installation tool are simple to use allowing for quick and precise installation
  • Accessory setup kit A-IEF-KIT (sold separately) ensures exact installation application depth with included thickness gauge and measuring tape
  • Long Life Cycle and minimal maintenance requirements with no moving parts to wear or break and electrodes that discourage fouling
  • Isolation valve accessory options (sold separately) allow for installation in operational systems via hot-tap kit or easy removal without system downtime

Applications

  • Boiler feed water
  • Chilled water
  • Open and closed loop condenser water
  • Irrigation system
  • Municipal water distribution
  • Process and coolant flow
  • Ground water remediation
  • Chemical processing
  • Pump protection
  • Wastewater
  • Mining

Dwyer IEF-HN-10-LCD Specifications

Service Compatible clean or dirty non coating, conductive liquids
Range 0 to 20 ft/s (0 to 6 m/s)
Wetted Materials Body shaft/fitting: 316 SS
Electrodes: 316 SS
Electrode cap: Polymer/Polystyrene
O-ring: Silicon
Accuracy ±0.5% of reading at calibrated velocity; ±1% of reading from 2 to 20 ft/s (0.6 to 6 m/s); ±0.02 ft/s (±0.006 m/s) at <2 ft/s (0.6 m/s)
Temperature Limits Ambient: -20 to 160°F (-29 to 71°C)
Process: 15 to 250°F (-9 to 121°C)
Storage: -40 to 185°F (-40 to 85°C)
Process Connection 1" NPT
Pressure Limits: 400 psi (27.6 bar) @ 100°F (37.8°C)
Drop: <0.1 psi at 12 ft/s in 4" (101.6 mm) and larger pipe
Outputs (1) Analog: 4 to 20 mA, 0 to 5 V, 0 to 10 V or 2 to 10 V (display selectable)
(1) Pulse/Frequency: 0 to 15 V peak pulse, 0 to 500 Hz or scalable pulse output (display selectable)
(2) Alarm: (1) Empty pipe detection or minimum/maximum velocity, (display selectable)
(1) Reverse flow output indication
Power Requirements 12 to 42.4 VDC, 0.25 A @ 24 VDC; 12 to 36 VAC
Display 2 x 2" (5.08 x 5.08 cm) graphic LCD with backlight
Conductivity >20 microsiemens
Enclosure Material: Powder coated die cast aluminum
Ratings: NEMA 4X (IP66)
Agency Approvals BTL, CE, NSF/ANSI 61 and 372
Click here for complete specifications on the Dwyer IEF-HN-10-LCD

What's included with the Dwyer IEF-HN-10-LCD

  • Dwyer IEF Insertion Electromagnetic Flow Transmitter with LCD display, PG 16 gland with 10' cable

Click on a category to view a selection of compatible accessories with the Dwyer IEF Insertion Electromagnetic Flow Transmitter with LCD display, PG 16 gland with 10' cable.

Dwyer A-IEF-KIT Setup Kit for the IEF series A-IEF-KIT
For use with IEF Insertion Electromagnetic Flow Transmitters.




Dwyer A-IEF-INGD Installation Guide/Alignment Kit for the IEF Series A-IEF-INGD
For use with IEF Insertion Electromagnetic Flow Transmitters.




Dwyer A-IEF-LID Replacement Blank Lid for the IEF series A-IEF-LID
For use with IEF Insertion Electromagnetic Flow Transmitters.




Dwyer A-IEF-VLV-SS Full Port Isolation Valve for the IEF series, 1¼", 316SS A-IEF-VLV-SS
A 1¼ 316SS full port isolation vavle for use with IEF Insertion Electromagnetic Flow Transmitters.




Ask a question about Dwyer IEF Insertion Electromagnetic Flow Transmitter with LCD display, PG 16 gland with 10' cable

Customer Reviews for the Dwyer IEF-HN-10-LCD

More Dwyer Products

Calibration Lab