This system is designed for fast, frequent and accurate testing of electrostatic discharge of personnel grounding items.
This system is designed for fast, frequent and accurate testing of electrostatic discharge of personnel grounding items.
Discontinued!
This product has been discontinued and is no longer available.
This is the direct replacement:
Features
SMARTLOG V5™ Operating Voltage | 100-240 VAC, 50/60 Hz |
Operating Temperature | 70°F to 85°F (21°C to 30°C) for 1 Gigohm test limit 41°F to 85°F (5°C to 30°C) for all other test limits |
Environmental Requirements | Indoor use only at altitudes less than 6500 ft. (2km) Maximum relative humidity of 80% up to 85°F (30°C) decreasing linearly to 50% @ 85°F (30°C) Maximum relative humidity of 50% at 1 Gigohm setting |
Dimensions | 7.9" x 5.8" x 1.9" (20.1cm x 14.7cm x 4.8cm) |
Weight | 2.0 lbs (0.9 kg) |
Test Accuracy | ±20% for 1 gigohm footwear test limit ±10% for all other test limits |
Test Switch Voltage | 5 VDC @ open circuit |
Wrist Strap and Footwear Test Voltage | 30 VDC @ open circuit |
Test current is limited by resistors and varies on the test range setting (100 kilohms - 1 gigohm) | |
Memory Capacity* | |
Test ID Length | Test Transactions |
4 | 16,100 |
5 | 15,300 |
6 | 14,600 |
7 | 14,000 |
8 | 13,400 |
9 | 12,900 |
10 | 12,400 |
11 | 11,900 |
12 | 11,500 |
13 | 11,100 |
14 | 10,700 |
15 | 10,400 |
16 | 10,100 |
*This only applies should the SmartLog V5 lose communication with the TEAM5 Software. Test transactions are automatically polled from the SmartLog's memory when connected to TEAM5 | |
DUAL INDEPENDENT FOOT PLATE | Dimensions 14.0" x 16.0" x 0.9" (35.6cm x 40.1cm x 2.3cm) Weight 7.5 lbs (3.4 kg) |
SMARTLOG V5™ Operating Voltage | 100-240 VAC, 50/60 Hz |
Operating Temperature | 70°F to 85°F (21°C to 30°C) for 1 Gigohm test limit 41°F to 85°F (5°C to 30°C) for all other test limits |
Environmental Requirements | Indoor use only at altitudes less than 6500 ft. (2km) Maximum relative humidity of 80% up to 85°F (30°C) decreasing linearly to 50% @ 85°F (30°C) Maximum relative humidity of 50% at 1 Gigohm setting |
Dimensions | 7.9" x 5.8" x 1.9" (20.1cm x 14.7cm x 4.8cm) |
Weight | 2.0 lbs (0.9 kg) |
Test Accuracy | ±20% for 1 gigohm footwear test limit ±10% for all other test limits |
Test Switch Voltage | 5 VDC @ open circuit |
Wrist Strap and Footwear Test Voltage | 30 VDC @ open circuit |
Test current is limited by resistors and varies on the test range setting (100 kilohms - 1 gigohm) | |
Memory Capacity* | |
Test ID Length | Test Transactions |
4 | 16,100 |
5 | 15,300 |
6 | 14,600 |
7 | 14,000 |
8 | 13,400 |
9 | 12,900 |
10 | 12,400 |
11 | 11,900 |
12 | 11,500 |
13 | 11,100 |
14 | 10,700 |
15 | 10,400 |
16 | 10,100 |
*This only applies should the SmartLog V5 lose communication with the TEAM5 Software. Test transactions are automatically polled from the SmartLog's memory when connected to TEAM5 | |
DUAL INDEPENDENT FOOT PLATE | Dimensions 14.0" x 16.0" x 0.9" (35.6cm x 40.1cm x 2.3cm) Weight 7.5 lbs (3.4 kg) |