Ideal for electrical contractors and industrial and commercial electricians, this insulation resistance tester also comes in a compact and rugged design and is easy to use. This value added kit includes the REED R9999 Industrial tool bag for FREE.
Ideal for electrical contractors and industrial and commercial electricians, this insulation resistance tester also comes in a compact and rugged design and is easy to use. This value added kit includes the REED R9999 Industrial tool bag for FREE.
Ideal for advanced industrial and electrical insulation testing, this insulation tester comes in a compact design and features versatility. Additionally, the multiple test voltages facilitate the tool for many troubleshooting, commissioning, and preventative maintenance applications.
Take advantage of the full feature set to easily and quickly perform advanced insulation resistance testing. Its handy size and lightweight make it easy to pack and use. Additional features, like the remote probe, save both time and money, especially when performing repetitive tests.
Features
Applications
R9999 Industrial Tool Bag
Features
Disconnect any electronic devices like motor drives, PLC’s, transmitters, etc. before performing insulation testing. Electronics can be damaged by applying higher than normal voltage.
The effect of temperature should be considered - it is recommended that tests be performed at a standard conductor temperature of 20 °C (68 °F) or that a temperature baseline is established while compensating future readings by using a DMM with a probe or an infrared thermometer.
Select a test voltage appropriate for the insulation being tested. The objective is to stress the insulation but not to over-stress it. When in doubt, use a lower test voltage. It’s usually appropriate to test insulation at twice the voltage it normally sees: for example 460 V to 600 V rated equipment is often tested at 1000 V.
When using an insulation tester, leave the leads connected when you stop the test. The insulation tester can discharge any residual test voltage.
Conductors that are close to each other have a normal capacitance. This will cause an insulation resistance reading to start low and increase steadily until it stabilizes. This type of increase is normal, but if the reading jumps violently down and up again this indicates arcing.
Although the current is tightly limited, an insulation tester can generate sparks and minor but painful burns. The unexpected surprise can cause an operator to jerk away. As always, work away from live systems and use safe work practices when working overhead.
AC/DC Voltage Specifications | |
Range | 600.0 V |
Resolution | 0.1 V |
Accuracy | 50 Hz to 400 Hz: ±(2% of rdg + 3 digits) |
Input Impedance | 3 MΩ (nominal), <100 pF |
Common Mode Rejection Ratio (1 kΩ unbalanced) | >60 dB at DC, 50 or 60 Hz |
Overload Protection | 600 V RMS or DC |
Earth Bond Resistance Specifications | |
Range | 20.00 Ω to 20.00 kΩ |
Resolution | 0.01 Ω to 0.01 kΩ |
Accuracy | ±(1.5% + 3 digits) |
Overload Protection | 2 V RMS or DC |
Open Circuit Test Voltage | >4.0 V, <8 V |
Short Circuit Current | >200.0 mA |
Insulation Specifications | |
Measurement Range | 0.01 MΩ to 10 GΩ |
Test Voltage | 50, 100, 250, 500, 1000 V |
Test Voltage Accuracy | +20%, -0% |
Short Circuit Current | 1 mA nominal |
Auto Discharge | Discharge time <0.5 second for C = 1 µF or less |
Live Circuit Indicator | Inhibit test if terminal voltage >30 V prior to initialization of test |
Maximum Capacitive Load | Operable with up to 1 µF load |
Live Circuit Detection | Inhibit test if terminal voltage >30 V prior to initialization of test |
Maximum Capacitive Load | Operable with up to 1 µF load |
Measure Accuracy | 50 V: ±(3% + 5) 100 V: ±(3% + 5) 250 V: ±(3% + 5) 500 V: ±(3% + 5) 1000 V: ±(3% + 5) to 2000 MΩ, ±(10% + 3) above 2000 MΩ |
Save time with the automatic calculation of polarization index and dielectric absorption ratio. Capable of reading resistance from 0.01 Ω to 20.00 kΩ.
Case is black and blue polyester with plastic injection logo. Outside Dimensions (LxWxH): 15.8 x 7.8 x 11.8" (400 x 200 x 300mm).
Two in one tools | Stand-alone tools | |||||
---|---|---|---|---|---|---|
Insulation test features | 1587 FC | 1577 | 1503 | 1507 | 1550C | 1555 |
Test voltages | 50 V, 100 V, 250 V, 500 V, 1000 V | 500 V, 1000 V | 500 V, 1000 V | 50 V, 100 V, 250 V, 500 V, 1000 V | 250 V to 5000 V | 250 V to 10,000 V |
Insulation resistance range | 0.01 MΩ to 2 GΩ | 0.01 MΩ to 600 GΩ | 0.01 MΩ to 2000 GΩ | 0.01 MΩ to 10 GΩ | 250 kΩ to 1 TΩ | 250 kΩ to 2 TΩ |
PI/DAR | ||||||
Auto discharge | ||||||
Timed ramp test (Breakdown) | ||||||
Pass/fail comparison | ||||||
Est. # of IRT tests | 1000 | 1000 | 2000 | 2000 | Various | Various |
Voltage > 30 V warning | ||||||
Memory | With Fluke Connect App | |||||
Remote test probe | ||||||
Lo ohms/earth-bond continuity | 200 mA source (10 mΩ resolution) | 200 mA source (10 mΩ resolution) | ||||
Display | Digital LCD | Digital LCD | Digital LCD | Digital LCD | Digital LCD/ analog display | Digital LCD/ analog display |
Hold/lock | ||||||
Multimeter features | ||||||
AC/DC volts | Note: Not all product features and specifications are listed in this table. For more complete information, see individual product data sheets. Footnotes: |
|||||
Current | ||||||
Resistance | ||||||
Continuity beeper | ||||||
Temperature (contact) | ||||||
Lo-pass filter2 | ||||||
Capacitance | ||||||
Diode test | ||||||
Frequency | ||||||
MIN/MAX | ||||||
Other features | ||||||
Backlight | ||||||
Software | Fluke Connect compatible | FlukeView® Forms Basic | Fluke View® Forms Basic | |||
Battery | 4 AA (NEDA 15A or IEC LR6) | 4 AA (NEDA 15A or IEC LR6) | 4 AA (NEDA 15A or IEC LR6) | 4 AA (NEDA 15A or IEC LR6) | Rechargeable | Rechargeable |
Click on a category to view a selection of compatible accessories with the Fluke 1507 Insulation Resistance Tester Kit - Includes the R9999 Industrial Tool Bag for FREE.
AC/DC Voltage Specifications | |
Range | 600.0 V |
Resolution | 0.1 V |
Accuracy | 50 Hz to 400 Hz: ±(2% of rdg + 3 digits) |
Input Impedance | 3 MΩ (nominal), <100 pF |
Common Mode Rejection Ratio (1 kΩ unbalanced) | >60 dB at DC, 50 or 60 Hz |
Overload Protection | 600 V RMS or DC |
Earth Bond Resistance Specifications | |
Range | 20.00 Ω to 20.00 kΩ |
Resolution | 0.01 Ω to 0.01 kΩ |
Accuracy | ±(1.5% + 3 digits) |
Overload Protection | 2 V RMS or DC |
Open Circuit Test Voltage | >4.0 V, <8 V |
Short Circuit Current | >200.0 mA |
Insulation Specifications | |
Measurement Range | 0.01 MΩ to 10 GΩ |
Test Voltage | 50, 100, 250, 500, 1000 V |
Test Voltage Accuracy | +20%, -0% |
Short Circuit Current | 1 mA nominal |
Auto Discharge | Discharge time <0.5 second for C = 1 µF or less |
Live Circuit Indicator | Inhibit test if terminal voltage >30 V prior to initialization of test |
Maximum Capacitive Load | Operable with up to 1 µF load |
Live Circuit Detection | Inhibit test if terminal voltage >30 V prior to initialization of test |
Maximum Capacitive Load | Operable with up to 1 µF load |
Measure Accuracy | 50 V: ±(3% + 5) 100 V: ±(3% + 5) 250 V: ±(3% + 5) 500 V: ±(3% + 5) 1000 V: ±(3% + 5) to 2000 MΩ, ±(10% + 3) above 2000 MΩ |
Save time with the automatic calculation of polarization index and dielectric absorption ratio. Capable of reading resistance from 0.01 Ω to 20.00 kΩ.
Case is black and blue polyester with plastic injection logo. Outside Dimensions (LxWxH): 15.8 x 7.8 x 11.8" (400 x 200 x 300mm).
Two in one tools | Stand-alone tools | |||||
---|---|---|---|---|---|---|
Insulation test features | 1587 FC | 1577 | 1503 | 1507 | 1550C | 1555 |
Test voltages | 50 V, 100 V, 250 V, 500 V, 1000 V | 500 V, 1000 V | 500 V, 1000 V | 50 V, 100 V, 250 V, 500 V, 1000 V | 250 V to 5000 V | 250 V to 10,000 V |
Insulation resistance range | 0.01 MΩ to 2 GΩ | 0.01 MΩ to 600 GΩ | 0.01 MΩ to 2000 GΩ | 0.01 MΩ to 10 GΩ | 250 kΩ to 1 TΩ | 250 kΩ to 2 TΩ |
PI/DAR | ||||||
Auto discharge | ||||||
Timed ramp test (Breakdown) | ||||||
Pass/fail comparison | ||||||
Est. # of IRT tests | 1000 | 1000 | 2000 | 2000 | Various | Various |
Voltage > 30 V warning | ||||||
Memory | With Fluke Connect App | |||||
Remote test probe | ||||||
Lo ohms/earth-bond continuity | 200 mA source (10 mΩ resolution) | 200 mA source (10 mΩ resolution) | ||||
Display | Digital LCD | Digital LCD | Digital LCD | Digital LCD | Digital LCD/ analog display | Digital LCD/ analog display |
Hold/lock | ||||||
Multimeter features | ||||||
AC/DC volts | Note: Not all product features and specifications are listed in this table. For more complete information, see individual product data sheets. Footnotes: |
|||||
Current | ||||||
Resistance | ||||||
Continuity beeper | ||||||
Temperature (contact) | ||||||
Lo-pass filter2 | ||||||
Capacitance | ||||||
Diode test | ||||||
Frequency | ||||||
MIN/MAX | ||||||
Other features | ||||||
Backlight | ||||||
Software | Fluke Connect compatible | FlukeView® Forms Basic | Fluke View® Forms Basic | |||
Battery | 4 AA (NEDA 15A or IEC LR6) | 4 AA (NEDA 15A or IEC LR6) | 4 AA (NEDA 15A or IEC LR6) | 4 AA (NEDA 15A or IEC LR6) | Rechargeable | Rechargeable |
Click on a category to view a selection of compatible accessories with the Fluke 1507 Insulation Resistance Tester Kit - Includes the R9999 Industrial Tool Bag for FREE.