This full-immersion PRT with bare wire is designed to perform in extreme temperatures where both the transition junction and the lead wires are required to withstand temperatures covering the entire operating range of the probe.
This full-immersion PRT with bare wire is designed to perform in extreme temperatures where both the transition junction and the lead wires are required to withstand temperatures covering the entire operating range of the probe.
This full-immersion PRT has a calibration accuracy of ±0.05°C.
Features
Temperature Range | -328 to 320°F (-200 to 160°C) |
Nominal Resistance At 0.01°C | 100Ω ±0.1Ω |
Temperature Coefficient | 0.00385Ω/Ω/°C |
Accuracy | ±0.04 at 0.01°C; ±0.06 at 160°C |
Short-Term Repeatability | ±0.03 at 0.01°C; ±0.04 at 160°C |
Drift | ±0.03 at 0.01°C; ±0.04 at 160°C |
Hysteresis | ±0.015°C |
Sheath Length | 1.97in ±0.2in (50mm ±5mm) |
Sheath Diameter | 0.13in ±0.004in (3.1mm ±0.1mm) |
Sheath Material | 316 SST |
Transition Junction Temperature Range | -328 to 320°F (-200 to 160°C) |
Sensor Length | 1.2in ±0.1 in (30mm ±3mm) |
Sensor Location | 1.2in ±0.04in (3mm ±1mm from tip) |
Minimum Insulation Resistance | 20MΩ at 23°C |
Minimum Immersion Length | Full immersion |
Maximum Immersion Depth In Liquid Medium | Full immersion |
Maximum Immersion Depth In Dry Medium | Full immersion |
Response Time | 12 seconds typical |
Self Heating (In 0°C Bath) | ±0.003°C |
Lead-Wire Cable Type | Enameled copper wire |
Lead-Wire Length | 8ft (2.4m) |
Lead-Wire Temperature Range | 160°C |
Calibration | Calibration not included. NVLAP accredited calibration available. See ordering information |
Click on a category to view a selection of compatible accessories with the Fluke 5606-50-B Full-Immersion PRT with Bare Wire.
Temperature Range | -328 to 320°F (-200 to 160°C) |
Nominal Resistance At 0.01°C | 100Ω ±0.1Ω |
Temperature Coefficient | 0.00385Ω/Ω/°C |
Accuracy | ±0.04 at 0.01°C; ±0.06 at 160°C |
Short-Term Repeatability | ±0.03 at 0.01°C; ±0.04 at 160°C |
Drift | ±0.03 at 0.01°C; ±0.04 at 160°C |
Hysteresis | ±0.015°C |
Sheath Length | 1.97in ±0.2in (50mm ±5mm) |
Sheath Diameter | 0.13in ±0.004in (3.1mm ±0.1mm) |
Sheath Material | 316 SST |
Transition Junction Temperature Range | -328 to 320°F (-200 to 160°C) |
Sensor Length | 1.2in ±0.1 in (30mm ±3mm) |
Sensor Location | 1.2in ±0.04in (3mm ±1mm from tip) |
Minimum Insulation Resistance | 20MΩ at 23°C |
Minimum Immersion Length | Full immersion |
Maximum Immersion Depth In Liquid Medium | Full immersion |
Maximum Immersion Depth In Dry Medium | Full immersion |
Response Time | 12 seconds typical |
Self Heating (In 0°C Bath) | ±0.003°C |
Lead-Wire Cable Type | Enameled copper wire |
Lead-Wire Length | 8ft (2.4m) |
Lead-Wire Temperature Range | 160°C |
Calibration | Calibration not included. NVLAP accredited calibration available. See ordering information |
Click on a category to view a selection of compatible accessories with the Fluke 5606-50-B Full-Immersion PRT with Bare Wire.