The transition junction seal and lead wire insulation of this full-immersion PRT won't degrade in common heat transfer fluids, such as silicone oil, mineral oil, ethanol and even liquid nitrogen.
The transition junction seal and lead wire insulation of this full-immersion PRT won't degrade in common heat transfer fluids, such as silicone oil, mineral oil, ethanol and even liquid nitrogen.
This full-immersion PRT has a calibration accuracy of ±0.05°C.
Features
Temperature Range | -328 to 320°F (-200 to 160°C) |
Nominal Resistance At 0.01°C | 100Ω ±0.1Ω |
Temperature Coefficient | 0.00385Ω/Ω/°C |
Accuracy | ±0.04 at 0.01°C; ±0.06 at 160°C |
Short-Term Repeatability | ±0.03 at 0.01°C; ±0.04 at 160°C |
Drift | ±0.03 at 0.01°C; ±0.04 at 160°C |
Hysteresis | ±0.015°C |
Sheath Length | 1.97in ±0.2in (50mm ±5mm) |
Sheath Diameter | 0.13in ±0.004in (3.1mm ±0.1mm) |
Sheath Material | 316 SST |
Transition Junction Temperature Range | -328 to 320°F (-200 to 160°C) |
Sensor Length | 1.2in ±0.1 in (30mm ±3mm) |
Sensor Location | 1.2in ±0.04in (3mm ±1mm from tip) |
Minimum Insulation Resistance | 20MΩ at 23°C |
Minimum Immersion Length | Full immersion |
Maximum Immersion Depth In Liquid Medium | Full immersion |
Maximum Immersion Depth In Dry Medium | Full immersion |
Response Time | 12 seconds typical |
Self Heating (In 0°C Bath) | ±0.003°C |
Lead-Wire Cable Type | Enameled copper wire |
Lead-Wire Length | 8ft (2.4m) |
Lead-Wire Temperature Range | 320°F (160°C) |
Calibration | Calibration not included. NVLAP accredited calibration available. See ordering information |
Click on a category to view a selection of compatible accessories with the Fluke 5606-50-D Full-Immersion PRT with 5-Pin DIN for Tweener Thermometers.
Temperature Range | -328 to 320°F (-200 to 160°C) |
Nominal Resistance At 0.01°C | 100Ω ±0.1Ω |
Temperature Coefficient | 0.00385Ω/Ω/°C |
Accuracy | ±0.04 at 0.01°C; ±0.06 at 160°C |
Short-Term Repeatability | ±0.03 at 0.01°C; ±0.04 at 160°C |
Drift | ±0.03 at 0.01°C; ±0.04 at 160°C |
Hysteresis | ±0.015°C |
Sheath Length | 1.97in ±0.2in (50mm ±5mm) |
Sheath Diameter | 0.13in ±0.004in (3.1mm ±0.1mm) |
Sheath Material | 316 SST |
Transition Junction Temperature Range | -328 to 320°F (-200 to 160°C) |
Sensor Length | 1.2in ±0.1 in (30mm ±3mm) |
Sensor Location | 1.2in ±0.04in (3mm ±1mm from tip) |
Minimum Insulation Resistance | 20MΩ at 23°C |
Minimum Immersion Length | Full immersion |
Maximum Immersion Depth In Liquid Medium | Full immersion |
Maximum Immersion Depth In Dry Medium | Full immersion |
Response Time | 12 seconds typical |
Self Heating (In 0°C Bath) | ±0.003°C |
Lead-Wire Cable Type | Enameled copper wire |
Lead-Wire Length | 8ft (2.4m) |
Lead-Wire Temperature Range | 320°F (160°C) |
Calibration | Calibration not included. NVLAP accredited calibration available. See ordering information |