This PRT is ideal for applications where block calibrators, furnaces or temperature points are being used above normal PRT temperatures thanks to its -200 to 661°C range. With internal protection, the thermometer helps reduce the risk of contamination, and it measures 20in and comes equipped with INFO-CON connections for 914X models.
This PRT is ideal for applications where block calibrators, furnaces or temperature points are being used above normal PRT temperatures thanks to its -200 to 661°C range. With internal protection, the thermometer helps reduce the risk of contamination, and it measures 20in and comes equipped with INFO-CON connections for 914X models.
High-temp secondary standards fill the gap between temperature-limited secondary PRTs (platinum resistance thermometers) and highly accurate SPRTs (standard platinum resistance thermometers).
Features
Temperature Range | -328 to 1,221.8°F (-200 to 661°C) |
Handle Temperature | 32 to 176°F (0 to 80°C) |
RTPW | 100Ω (±1Ω) |
Resistance Ratio W(Ga) | W(302.9146K) ≥ 1.11807 α ≥ 0.003925 |
Calibrated Accuracy (Includes Calibration And 100-Hour Drift) (k=2) | ±0.006°C at -200°C; ±0.006°C at 0°C; ±0.015°C at 420°C; ±0.022°C at 661°C |
Stability | ±0.003°C |
Long-Term Drift (k=2) | < 0.006°C/100 hours at 661°C |
Immersion | At least 5in (12.7cm) recommended |
Sheath | Inconel 600 |
Lead Wires | 4-wire Super-Flex PVC, 22AGW |
Termination | Gold-plated spade lugs, or specify |
Size | 0.25 x 12, 15 or 20in (6.35 x 305, 381 or 508mm) standard, custom lengths available |
Click on a category to view a selection of compatible accessories with the Fluke 5626-20-A Secondary Standard Platinum Resistance Thermometer (PRT) with INFO-CON for 914X Models, 20in, 100Ω.
Temperature Range | -328 to 1,221.8°F (-200 to 661°C) |
Handle Temperature | 32 to 176°F (0 to 80°C) |
RTPW | 100Ω (±1Ω) |
Resistance Ratio W(Ga) | W(302.9146K) ≥ 1.11807 α ≥ 0.003925 |
Calibrated Accuracy (Includes Calibration And 100-Hour Drift) (k=2) | ±0.006°C at -200°C; ±0.006°C at 0°C; ±0.015°C at 420°C; ±0.022°C at 661°C |
Stability | ±0.003°C |
Long-Term Drift (k=2) | < 0.006°C/100 hours at 661°C |
Immersion | At least 5in (12.7cm) recommended |
Sheath | Inconel 600 |
Lead Wires | 4-wire Super-Flex PVC, 22AGW |
Termination | Gold-plated spade lugs, or specify |
Size | 0.25 x 12, 15 or 20in (6.35 x 305, 381 or 508mm) standard, custom lengths available |
Click on a category to view a selection of compatible accessories with the Fluke 5626-20-A Secondary Standard Platinum Resistance Thermometer (PRT) with INFO-CON for 914X Models, 20in, 100Ω.