GRAPHTEC GL240 Midi Data Logger, 10 channel, 10 ms/1 channel

Model: GL240

GRAPHTEC GL240 Midi Data Logger, 10 channel, 10 ms/1 channel

Model: GL240

Ensure signals are not corrupted by inputs from other channels with this midi data logger featuring an isolated input system and channel-to-channel isolation. In addition, this logger accepts voltage, temperature, humidity, pulse, and logic signals and features simultaneous scanning for up to 100 ms when measuring all ten channels.

Ensure signals are not corrupted by inputs from other channels with this midi data logger featuring an isolated input system and channel-to-channel isolation. In addition, this logger accepts voltage, temperature, humidity, pulse, and logic signals and features simultaneous scanning for up to 100 ms when measuring all ten channels.

Sale Price $995.00 USD
Regular Price $1095.00 USD
Availability 3 in Stock
Quantity

GRAPHTEC GL240 Offers

Enable dependable long-term measurement with this midi data logger featuring built-in 4 GB flash memory and an SD card slot for an SDHC memory card of up to 32 GB. In addition, this logger features a bar chart data display, an alarm output function, and networking features.

Features

  • Maximum sampling interval up to 10 ms/1 ch. 100 ms for all 10 channels
  • All channels isolated
  • Alarm output ports up to 4 channels
  • Logic/Pulse signal input port up to 4 channels
  • Flexible input system for voltage, temp, humidity, pulse and logic signals
  • Smartphone, remote access monitoring capability
  • Analog signal input port
  • Easy operation with control button
  • USB 2.0
  • Ability to access additional (GL100) sensors and adapters
  • Hot swapping the SD memory card; SD card can be replaced during recording data when the sampling interval is 100ms or slower
  • USB drive mode enables data to be transferred to the PC from the unit in drag and drop fashion, this mode lets it becomes a flash USB drive
  • Match functions for scaling; Math functions are available for scaled input from sensors and transducers with V DC scaled output or 4 to 20 mA current loop

Ring capture function

Most recent data is saved when the memory is configured to a ring memory mode and circulates the recording until memory is filled Recording continues by deleting the oldest recorded files. (Number of capturing data is between 1000 to 2,000,000 points when using this function)

Relay capture function

When memory is configured in the "Relay" mode, data is saved continuously without any loss.  Files are created one after another with up to 2 GB size per file.

4.3" (10.92 cm) wide color LCD

Carries a clear 4.3" (10.92 cm) TFT color LCD monitor. (WQVGA480 × 272 dot) Waveform or digital format data can be reviewed in real time. Set up conditions can also be easily viewed on the screen offering a full standalone system without the need of a PC.

Applications

  • Aftermarket automotive tuning
  • Agriculture and food manufacturing
  • Greenhouse and hydroponics
  • Construction and civil engineering
  • Machinery manufacturing
  • Automotive industry
  • Aerospace and military industry
  • Utilities/gas and electric
  • Battery manufacturing
  • Electrical appliance and office equipment
  • Electrical service and maintenance companies
  • Food processing
  • Rail transportation
  • Raw materials and components manufacturing
  • Research and development

GRAPHTEC GL240 Specifications

Number of Analog Input Channels 10 channels
External Input/Output Input: Trigger or sampling (1 channel), logic/pulse (4 channels)
Output: Alarm (4 channels)
Sampling Interval 10 ms to 1 hour (10 ms to 50 ms: voltage only) , External signal
Time Scale of Waveform Display 1 second to 24 hour/division
Trigger, Alarm Function Trigger action: Start or stop capturing data by the trigger
Repeat action: Off, On (auto rearmed)

Trigger source:
Start: Off, Measured signal, Alarm, External, Clock, Week or Time
Stop: Off, Measured signal, Alarm, External, Clock, Week or Time

Condition Setting:
Combination: OR or AND
Analog signal: Rising (High), Falling (Low), Window-in, Window-out
Logic signal: Pattern (combination of each input signal in high or low)
Pulse (number of count): Rising (High), Falling (Low), Window-in, Window-out

Alarm output: Outputs a signal when alarm condition occurs in the input signal
Pulse Input Function Rotation count (RPM): Counts the number of pulses per sampling interval and converts to rpm (rotations per minute), Number of pulses for one rotation may be set to 50, 500, 5000, 50 k, 500 k, 5M, 50 M, 500 M rpm/F.S. (rpm./full scale)
Accumulating count: Accumulates the number of pulses from the start of measurement 50, 500, 5000, 50 k, 500 k, 5 M, 50 M, 500 M C/F.S. (counts/full scale)
Instant count: Counts the number of pulses per sampling interval 50, 500, 5000, 50 k, 500 k, 5 M, 50 M, 500 M C/F.S. (counts/full scale)
Calculation Function Between channels: Addition, Subtraction, Multiplication, and Division for analog input
Statistical: Select two calculations from Average, Peak, Maximum, Minimum, RMS
Search Function Search for analog signal levels, values of logic or pulse or alarm point in captured data
Interface to PC USB (Hi-speed)
Storage Device Internal: Built-in 4 GB flash memory
External: One SD card slot (Support SDHC memory card, up to 32 GB)
Saved contents: Captured data, Setting conditions, Screen copy
Capturing Mode Mode: Normal, Ring, Relay
Ring: Saves most recent data (Number of captured data: 1000 to 2,000,000 points)
Relay: Saves data to multiple files without losing data until data capturing is stopped
Replay Data Replays captured data that was saved in the unit (in GBD or CSV format)
Scaling (Engineering Unit) Function Measured value can be converted to the specified engineering unit
Analog voltage: Converts using four reference points (gain, offset)
Temperature: Converts using two reference points (offset)
Pulse count: Converts using two reference points (gain)
Action During Data Capture Displaying parst data (using dual display mode, current and past data)
Hot-swapping the SD memory card
Saving data in between cursors
Display Size: 4.3" (10.92 cm) TFT color LCD (WQVGA: 480 x 272 dots)
Information: Waveform in Y-T with digital values, Waveform only, Digital value, Digital values and statistics values
Operating Environment 32 to 113°F (0 to 45°C), 5 to 85% RH (non condensed)
When operating with battery pack 32 to 104°F (0 to 40°C), charging battery 59 to 95°F (15 to 35°C)
Power Source: AC adapter 100 to 240 V AC, 50/60 Hz
Consumption: Maximum 36 V A
Dimensions 7.4 x 4.6 x 1.65" (188 x 117 x 42 mm) Excluding projections
Weight 1.1 lbs (500 g)
Click here for complete specifications on the GRAPHTEC GL240

What's included with the GRAPHTEC GL240

  • Data Logger
  • AC Cable/Adapter
  • Ferrite Core
  • Quick Start Guide
  • Software and Manual on CD-ROM
  • 3-Year Standard Warranty

Click on a category to view a selection of compatible accessories with the GRAPHTEC GL240 Midi Data Logger, 10 channel, 10 ms/1 channel.

GRAPHTEC B-513 Input/Output Cable for the GL series, 6.56', bare tips B-513
Compatible with the GL series data application software, the input/output cable has bare tips and a length of 6.56168' (2 m).




GRAPHTEC B-530 Humidity Sensor, -25 to 80°C B-530
Comes with a 3 m length cable, the humidity sensor with a dedicated power connector has an allowable temperature range of -25 to 80°C.




GRAPHTEC B-536US-240R Pelican Case for the GL240 data logger B-536US-240R
Specifically designed and for the GL240 data logger, the custom designed Pelican case has foam interior to protect the unit. It is watertight, crushproof and dustproof. It also has an IP67 rating.




GRAPHTEC B-551-10 Shunt Resistors, 250 ohm B-551-10
Featuring a shunt resistance of 250 Ω, the shunt resistor is soldered on lugs for terminal block use. It comes in a pack of 10




Ask a question about GRAPHTEC GL240 Midi Data Logger, 10 channel, 10 ms/1 channel

Customer Reviews for the GRAPHTEC GL240

GRAPHTEC GL240 Offers

Enable dependable long-term measurement with this midi data logger featuring built-in 4 GB flash memory and an SD card slot for an SDHC memory card of up to 32 GB. In addition, this logger features a bar chart data display, an alarm output function, and networking features.

Features

  • Maximum sampling interval up to 10 ms/1 ch. 100 ms for all 10 channels
  • All channels isolated
  • Alarm output ports up to 4 channels
  • Logic/Pulse signal input port up to 4 channels
  • Flexible input system for voltage, temp, humidity, pulse and logic signals
  • Smartphone, remote access monitoring capability
  • Analog signal input port
  • Easy operation with control button
  • USB 2.0
  • Ability to access additional (GL100) sensors and adapters
  • Hot swapping the SD memory card; SD card can be replaced during recording data when the sampling interval is 100ms or slower
  • USB drive mode enables data to be transferred to the PC from the unit in drag and drop fashion, this mode lets it becomes a flash USB drive
  • Match functions for scaling; Math functions are available for scaled input from sensors and transducers with V DC scaled output or 4 to 20 mA current loop

Ring capture function

Most recent data is saved when the memory is configured to a ring memory mode and circulates the recording until memory is filled Recording continues by deleting the oldest recorded files. (Number of capturing data is between 1000 to 2,000,000 points when using this function)

Relay capture function

When memory is configured in the "Relay" mode, data is saved continuously without any loss.  Files are created one after another with up to 2 GB size per file.

4.3" (10.92 cm) wide color LCD

Carries a clear 4.3" (10.92 cm) TFT color LCD monitor. (WQVGA480 × 272 dot) Waveform or digital format data can be reviewed in real time. Set up conditions can also be easily viewed on the screen offering a full standalone system without the need of a PC.

Applications

  • Aftermarket automotive tuning
  • Agriculture and food manufacturing
  • Greenhouse and hydroponics
  • Construction and civil engineering
  • Machinery manufacturing
  • Automotive industry
  • Aerospace and military industry
  • Utilities/gas and electric
  • Battery manufacturing
  • Electrical appliance and office equipment
  • Electrical service and maintenance companies
  • Food processing
  • Rail transportation
  • Raw materials and components manufacturing
  • Research and development

GRAPHTEC GL240 Specifications

Number of Analog Input Channels 10 channels
External Input/Output Input: Trigger or sampling (1 channel), logic/pulse (4 channels)
Output: Alarm (4 channels)
Sampling Interval 10 ms to 1 hour (10 ms to 50 ms: voltage only) , External signal
Time Scale of Waveform Display 1 second to 24 hour/division
Trigger, Alarm Function Trigger action: Start or stop capturing data by the trigger
Repeat action: Off, On (auto rearmed)

Trigger source:
Start: Off, Measured signal, Alarm, External, Clock, Week or Time
Stop: Off, Measured signal, Alarm, External, Clock, Week or Time

Condition Setting:
Combination: OR or AND
Analog signal: Rising (High), Falling (Low), Window-in, Window-out
Logic signal: Pattern (combination of each input signal in high or low)
Pulse (number of count): Rising (High), Falling (Low), Window-in, Window-out

Alarm output: Outputs a signal when alarm condition occurs in the input signal
Pulse Input Function Rotation count (RPM): Counts the number of pulses per sampling interval and converts to rpm (rotations per minute), Number of pulses for one rotation may be set to 50, 500, 5000, 50 k, 500 k, 5M, 50 M, 500 M rpm/F.S. (rpm./full scale)
Accumulating count: Accumulates the number of pulses from the start of measurement 50, 500, 5000, 50 k, 500 k, 5 M, 50 M, 500 M C/F.S. (counts/full scale)
Instant count: Counts the number of pulses per sampling interval 50, 500, 5000, 50 k, 500 k, 5 M, 50 M, 500 M C/F.S. (counts/full scale)
Calculation Function Between channels: Addition, Subtraction, Multiplication, and Division for analog input
Statistical: Select two calculations from Average, Peak, Maximum, Minimum, RMS
Search Function Search for analog signal levels, values of logic or pulse or alarm point in captured data
Interface to PC USB (Hi-speed)
Storage Device Internal: Built-in 4 GB flash memory
External: One SD card slot (Support SDHC memory card, up to 32 GB)
Saved contents: Captured data, Setting conditions, Screen copy
Capturing Mode Mode: Normal, Ring, Relay
Ring: Saves most recent data (Number of captured data: 1000 to 2,000,000 points)
Relay: Saves data to multiple files without losing data until data capturing is stopped
Replay Data Replays captured data that was saved in the unit (in GBD or CSV format)
Scaling (Engineering Unit) Function Measured value can be converted to the specified engineering unit
Analog voltage: Converts using four reference points (gain, offset)
Temperature: Converts using two reference points (offset)
Pulse count: Converts using two reference points (gain)
Action During Data Capture Displaying parst data (using dual display mode, current and past data)
Hot-swapping the SD memory card
Saving data in between cursors
Display Size: 4.3" (10.92 cm) TFT color LCD (WQVGA: 480 x 272 dots)
Information: Waveform in Y-T with digital values, Waveform only, Digital value, Digital values and statistics values
Operating Environment 32 to 113°F (0 to 45°C), 5 to 85% RH (non condensed)
When operating with battery pack 32 to 104°F (0 to 40°C), charging battery 59 to 95°F (15 to 35°C)
Power Source: AC adapter 100 to 240 V AC, 50/60 Hz
Consumption: Maximum 36 V A
Dimensions 7.4 x 4.6 x 1.65" (188 x 117 x 42 mm) Excluding projections
Weight 1.1 lbs (500 g)
Click here for complete specifications on the GRAPHTEC GL240

What's included with the GRAPHTEC GL240

  • Data Logger
  • AC Cable/Adapter
  • Ferrite Core
  • Quick Start Guide
  • Software and Manual on CD-ROM
  • 3-Year Standard Warranty

Click on a category to view a selection of compatible accessories with the GRAPHTEC GL240 Midi Data Logger, 10 channel, 10 ms/1 channel.

GRAPHTEC B-513 Input/Output Cable for the GL series, 6.56', bare tips B-513
Compatible with the GL series data application software, the input/output cable has bare tips and a length of 6.56168' (2 m).




GRAPHTEC B-530 Humidity Sensor, -25 to 80°C B-530
Comes with a 3 m length cable, the humidity sensor with a dedicated power connector has an allowable temperature range of -25 to 80°C.




GRAPHTEC B-536US-240R Pelican Case for the GL240 data logger B-536US-240R
Specifically designed and for the GL240 data logger, the custom designed Pelican case has foam interior to protect the unit. It is watertight, crushproof and dustproof. It also has an IP67 rating.




GRAPHTEC B-551-10 Shunt Resistors, 250 ohm B-551-10
Featuring a shunt resistance of 250 Ω, the shunt resistor is soldered on lugs for terminal block use. It comes in a pack of 10




Ask a question about GRAPHTEC GL240 Midi Data Logger, 10 channel, 10 ms/1 channel

Customer Reviews for the GRAPHTEC GL240

More GRAPHTEC Products

Calibration Lab