Ensure that signals are not corrupted by noise from other channels with this multi-use data logger's high isolation inputs. Suitable for remote monitoring and controlling, this data logger supports WEB servers, FTP servers, and FTP client network functions. In addition, this logger transfers data to PLC via Modbus/TCP protocol.

Ensure that signals are not corrupted by noise from other channels with this multi-use data logger's high isolation inputs. Suitable for remote monitoring and controlling, this data logger supports WEB servers, FTP servers, and FTP client network functions. In addition, this logger transfers data to PLC via Modbus/TCP protocol.

Your Price $1200.00 USD
Availability 2 to 3 Weeks
Quantity

GRAPHTEC GLT400 Offers

Control, monitor, and transfer data to PC via web browser with this data logger. In addition, this data logger features long-term data recording, GL-Connection software, and is expandable up to 200 channels.

Features

  • Transferring data to PLC via Modbus/TCP protocol
  • Supports WEB server, FTP server and FTP client network functions for remote monitoring and controlling
  • High isolation inputs to ensure signals are not corrupted by noise from other channels
  • Connect as a remote terminal unit of GL840
  • Mount or embed in a system and remote monitoring by PC: Real time remote monitoring and control via Ethernet, wireless LAN* and USB (Software is standard accessory)
    ** Option B-568 (sold separately) is required for wireless LAN operation
  • Modbus/TCP for for PLC I/O channels: Bidirectional communication between PLC and GLT400 via Modbus/TCP, start or stop command can be sent from PLC
  • Enable to use as PC hosted data logger: Connection to PC via USB, LAN and wireless LAN. Standalone or PC hosted data logger for R&D, quality and production
  • Connect as a remote terminal unit of GL840: Communications via Ethernet or wireless LAN* (Expand up to 200 channels {including GLT400} per GL840 or up to 5 units of GLT400 can be connected to GL840 host) setup and control from GL840 and captured data can be stored on GL840 which is measured from GLT400
  • Expandable up to 200 channels: From 20 to 200 channels, the GLT400 is scalable to meet yout future needs
  • Web browser function: This datalogger can be controlled, monitored, and data transferred to PC via web browser
  • USB drive mode: Internal memory is recognized as a removal disk, this mode facilitates file manipulation such as transfer and deletion
  • Hot-swapping the SD memory card: SD card can be replaced during data capturing when the sampling interval is 100 ms or slower
  • Back up recording data:

Notify by alarm output function

Alarm level can be set for each channel:

  • Alarm lamp on device
  • Email alarm notification
  • Alarm output (4 ports), output port can be chosen for each channel (*Input/output cable B-513 {sold separately} is require)

Useful function for long term data recording

  • Ring capture function: The old data is deleted, and most recent data is saved. When stop the recording, selected data point is saved. (Number of capturing data is 1000 to 2000000 points)
  • Relay capture function: Data is continuously saved with hard disk space or capturing time without losing any data until capturing is stopped. The multiple files can be joined on GL-connection.

4 to 20mA Current measurement

  • Shut resistance 250 Ω for current input (not compatible with the B-564-SL)
  • Installing 250 Ω (0.1%) resistor for converting 1 to 5 V
  • EU scaling function allows diverse measurements by converting voltage to user defined engineering units

Long term recording capability

The standard features include a built-in 4 GB Flash memory, and SD card slot up to 32 GB to be used as external storage for recorded data at the same time as transferring the data to a PC (one file size is up to 2 GB). Selectable from two types of file formats: Graphtec Binary Data (GBD), CSV data which can be open by Excel, supplied software allows GBD files to be converted to CSV format

Setting app

Easily enter settings and monitor measured data from a PC. This datalogger is ideal for use with single unit. This datalogger inherited the setting screen menus from GL series.

GL-connection

Maximum 20 units of this datalogger can be connected. Display modes come standard with a Y-T view, digital view, XY view and FFT view. Contains direct Excel functions and a file connection function. Can convert GBD files to CSV format.

FTP backup functions

Periodically backing up recording data to FTP server. Backup Interval: 1H・2H・6H・12H・24H・per file when the upload is succeeded, the file can be deleted automatically from device memory.

GRAPHTEC GLT400 Specifications

Number of Analog Terminal Units Up to 10 units (200 channels)
Sampling Speed 10 msec to 1 hour (Only voltage: 10 to 50 ms with limited channels), external (Able to select at only "STAND ALONE" mode)*1
*1The input/output cable for GL B-513 option (sold separately) is required to use the external I/O function.
Trigger/Alarm Function Repeat trigger: On/OFF

Trigger conditions: Start/Stop: Off, level value, alarm, external input, specified time, specified day of the week, certain time

Alarm judgment modes:
Combination: Analog, Logic or "AND"/"OR" of pulse
Analog judgment: H (↑), L (↓), Window In, Window Out Logic judgment: Pattern
Pulse judgment: H (↑), L (↓), Window In, Window Out

Operation of the alarm output function: Alarm lamp on device, email alarm notification, alarm output (4 channels ("REMOTE" 1 channel only)
Alarm output (hold function): Yes
External Input/Output*1 Input/output types: Trigger input (1 channel) or External sampling input (1 channel)/logic input (4 channels) or pulse input (4 channels), only for STAND-ALONE mode

Input specifications:
Input voltage range: 0 to 30 V (single-ended ground input)
Input signal: No-voltage contact (a-contact, b-contact, NO, NC), open collector, voltage input
Input threshold voltage: Approximately 2.5 V, hysteresis: Approximately 0.5 V (2.5 to 3 V)*7

Alarm output specifications:
Alarm output: 4 channel ("REMOTE" 1 channel only)
Output format: Open collector output (5 V, pull-up resistance 10 KΩ)

Collector-GND voltage: 50 V, collector current: 2 A, collector dissipation: 0.3 W
*1The input/output cable for GL B-513 option (sold separately) is required to use the external I/O function.
*7Switch between logic and pulse. Switch between trigger and external sampling.
Pulse Input Revolutions mode: This mode counts the number of pulses per sampling interval, and then converts them by multiplying the scaling factor to the RPM. Settable the number of pulses per revolution during revolution. Spans: 50, 500, 5000, 50 k, 500 k, 5 M, 50 M, 500 M RPM/F.S.

Counts mode: Displays a count of the number of pulses for each sampling interval from the start of measurement. Spans: 50, 500, 5000, 50 k, 500 k, 5 M, 50 M, 500 M C/F.S.

Inst. mode: Counts the number of pulses for each sampling interval. Resets the count value after each sampling interval. Spans: 50, 500, 5000, 50 k, 500 k, 5 M, 50 M, 500 M C/F.S.

Maximum number of pulse inputs:
Maximum input frequency: 50 kHz
Maximum number of count: 50 kC/sampling (16-bit counter)
Math Channels Computation types: +,-, ×, ÷ (Arithmetic) CH: Input channel (CH1 to 200)
Scaling Function(EU) 4 points can be set for each channel, temperature range: 2 points is available
Annotation Input Alphanumerics, number of characters: 31
Function: A comment can be input for each channel
PC I/F Types: Ethernet (10BASE-T/100BASE-TX), USB 2.0, wireless LAN option (sold separately)
Functions: Transfer device data to the PC, control device from PC, and connect as a remote terminal unit of GL840
Ethernet functions: Web server function, FTP server function, FTP client function, NTP client function, DHCP client function, DHCP server function, modbus/TCP communication
USB functions: USB drive mode: Transfer and delete the captured files in the internal memory or SD CARD
Realtime data transfer speed: 10 msec/1 channel maximum (*The transfer speed varies depends on the number of channels)
Memory Devices Internal memory: Approximately 4 GB
External memory slot: SD CARD slot: 1 (Compatible with SDHC, up to approximately 32 GB memory available)
Maximum size for 1 file: 1 file size is up to 2 GB
Memory contents: Setup conditions/measured data
Capture Function Functions: OFF, ring capturing, relay capturing
Ring capturing: If the number of recordings is exceeded "1000 to 2,000,000", capturing recording will continue on another file with deleting the oldest one. When ring capture is ON, the possible recording time becomes less.
Relay capturing: The captured data is continuously captured by files separated in the set relay unit without losing data
File format: GBD (Graphtec Binary Data) format/CSV format
Functions during capture: Replacement of SD CARD
Data Backup Function*2 Backup interval: OFF, 1, 2, 6, 12, 24 hours, each file
Backup destination: Internal memory, SD card, FTP
Data format: GBD·CSV
*2(Each file can be selected only when the backup destination is set to FTP and the captured file is deleted when the backup of the FTP client settings is activated normally)When the RING mode or external pulse synchronization sampling is selected for recording, the backup function is not available. When there are many active channels or the sampling time is fast or the backup interval is long, it may take time to close the data file after recording stops because the size of the data to be backed up becomes large. When saving file to FTP server using wireless LAN connection, backup may fail depending on the communication condition. Available sampling speed is 100 ms or slower when using the CSV format. When backup is enabled and data file format is specified as CSV format, SD memory card exchange (hot-swapping) and RELAY recording are not available.
Operating Environment -4 to 140°F (20 to 60°C) only when using B-564 or B-564SL (sold separately) input terminals and DC power
(0 to 45°C) when using B-565 (sold separately) input terminal or AC adapter
5 to 85% R.H. (non condensed)
(When using the USB PD as the power supply, the specification is based on power supply requirements)
Power Source AC adapter: AC 100~240V/50~60 Hz
DC power: 8.5 to 24 V DC (Maximum 26.4 V), requires option B-514 (sold separately)
USB PD: External USB PD compatible battery (USB power delivery revision 2.0 later), not supplied
Power Consumption Below 24 VA (when using the supplied AC adapter, AC100V)
Others Vibration: Automobile parts Type 1 Class A equivalent
Approximate Dimensions (Excluding Protrusions) Standard terminal B-564 (sold separately) or screwless terminal B-564SL (sold separately): 7.38 x 7.2 x 2.57" (187.5 × 183 × 65.5 mm)
Approximate Weight (Excluding AC Adapter) Standard terminal B-564 (sold separately) is attached: 2.4 lbs (1090 g)
Standard terminal B-564 (sold separately) is attached: 2.25 lbs (1020 g)
Withstand high-voltage high-precision terminal B-565 (sold separately) is attached: 2.47 lbs (1120 g)
Click here for complete specifications on the GRAPHTEC GLT400

What's included with the GRAPHTEC GLT400

  • Midi Multi-Use Data Logger
  • 3 x Spacers
  • AC Cable/AC Adapter
  • Quick Start Guide

Click on a category to view a selection of compatible accessories with the GRAPHTEC GLT400 Midi Multi-Use Data Logger.

GRAPHTEC B-513 Input/Output Cable for the GL series, 6.56', bare tips B-513
Compatible with the GL series data application software, the input/output cable has bare tips and a length of 6.56168' (2 m).




GRAPHTEC B-567-20 Extension Cable for the GL840 series, 6.56' B-567-20
Compatible with the GL840 series, this 6.56' (2 m) extension cable is an accessory.




GRAPHTEC B-567-05 Extension Cable for the GL840 series, 19.68" B-567-05
Compatible with the GL840, this 19.68" (50 cm) extension cable is an accessory.




GRAPHTEC B-566 Extension Terminal Base Unit for the GL840 series B-566
Compatible with the GL840 series, this extension terminal base unit allows you to add additional terminals up to 200 channels or 10 terminal blocks. In addition, the original terminal from the main body connects with this terminal base unit.




GRAPHTEC B-565 Screw Input Terminal Block for the GL840-WV and GLT400, 20 channels, withstand voltage type B-565
Compatible with the GL840-WV and GLT400, this input terminal block features 20 channels, high accuracy, high isolation, and can withstand high voltage.




GRAPHTEC B-564SL Screwless Input Terminal Block for the GL840-M and GLT400, 20 channels, multi-input type B-564SL
Compatible with the GL840-M and GLT400, this multi-input type screwless terminal block features 20 channels.




GRAPHTEC B-564 Screw Input Terminal Block for the GL840-M and GLT400, 20 channels, multi-input type B-564
Compatible with the GL840-M and GLT400, this multi-input type screw terminal block features 20 channels.




GRAPHTEC B-540 DIN Rail Bracket for the GLT400/B-566/GL840 B-540
Compatible with the GL840, GLT400, and B-566, this DIN rail bracket is an accessory.




GRAPHTEC ACADP-20 AC Adapter for the GL220/240/820/840/980/2000 with AC power cable (CE) ACADP-20
Compatible with the GL220, GL240, GL820, GL840, GL980, and GL2000, this AC adapter features a CE-rated AC power cable.




GRAPHTEC B-551 Shunt Resistor, 250 ohm B-551
Featuring a shunt resistance of 250 Ω, the shunt resistor is soldered on lugs for terminal block use.




GRAPHTEC B-530 Humidity Sensor, -25 to 80°C B-530
Comes with a 3 m length cable, the humidity sensor with a dedicated power connector has an allowable temperature range of -25 to 80°C.




GRAPHTEC B-568 Wireless LAN Unit for the GL840/GL240/GLT400 B-568
Compatible with the GL840 series, GL240, and GLT400, this wireless LAN unit is a wireless communication option.




Ask a question about GRAPHTEC GLT400 Midi Multi-Use Data Logger

Customer Reviews for the GRAPHTEC GLT400

GRAPHTEC GLT400 Offers

Control, monitor, and transfer data to PC via web browser with this data logger. In addition, this data logger features long-term data recording, GL-Connection software, and is expandable up to 200 channels.

Features

  • Transferring data to PLC via Modbus/TCP protocol
  • Supports WEB server, FTP server and FTP client network functions for remote monitoring and controlling
  • High isolation inputs to ensure signals are not corrupted by noise from other channels
  • Connect as a remote terminal unit of GL840
  • Mount or embed in a system and remote monitoring by PC: Real time remote monitoring and control via Ethernet, wireless LAN* and USB (Software is standard accessory)
    ** Option B-568 (sold separately) is required for wireless LAN operation
  • Modbus/TCP for for PLC I/O channels: Bidirectional communication between PLC and GLT400 via Modbus/TCP, start or stop command can be sent from PLC
  • Enable to use as PC hosted data logger: Connection to PC via USB, LAN and wireless LAN. Standalone or PC hosted data logger for R&D, quality and production
  • Connect as a remote terminal unit of GL840: Communications via Ethernet or wireless LAN* (Expand up to 200 channels {including GLT400} per GL840 or up to 5 units of GLT400 can be connected to GL840 host) setup and control from GL840 and captured data can be stored on GL840 which is measured from GLT400
  • Expandable up to 200 channels: From 20 to 200 channels, the GLT400 is scalable to meet yout future needs
  • Web browser function: This datalogger can be controlled, monitored, and data transferred to PC via web browser
  • USB drive mode: Internal memory is recognized as a removal disk, this mode facilitates file manipulation such as transfer and deletion
  • Hot-swapping the SD memory card: SD card can be replaced during data capturing when the sampling interval is 100 ms or slower
  • Back up recording data:

Notify by alarm output function

Alarm level can be set for each channel:

  • Alarm lamp on device
  • Email alarm notification
  • Alarm output (4 ports), output port can be chosen for each channel (*Input/output cable B-513 {sold separately} is require)

Useful function for long term data recording

  • Ring capture function: The old data is deleted, and most recent data is saved. When stop the recording, selected data point is saved. (Number of capturing data is 1000 to 2000000 points)
  • Relay capture function: Data is continuously saved with hard disk space or capturing time without losing any data until capturing is stopped. The multiple files can be joined on GL-connection.

4 to 20mA Current measurement

  • Shut resistance 250 Ω for current input (not compatible with the B-564-SL)
  • Installing 250 Ω (0.1%) resistor for converting 1 to 5 V
  • EU scaling function allows diverse measurements by converting voltage to user defined engineering units

Long term recording capability

The standard features include a built-in 4 GB Flash memory, and SD card slot up to 32 GB to be used as external storage for recorded data at the same time as transferring the data to a PC (one file size is up to 2 GB). Selectable from two types of file formats: Graphtec Binary Data (GBD), CSV data which can be open by Excel, supplied software allows GBD files to be converted to CSV format

Setting app

Easily enter settings and monitor measured data from a PC. This datalogger is ideal for use with single unit. This datalogger inherited the setting screen menus from GL series.

GL-connection

Maximum 20 units of this datalogger can be connected. Display modes come standard with a Y-T view, digital view, XY view and FFT view. Contains direct Excel functions and a file connection function. Can convert GBD files to CSV format.

FTP backup functions

Periodically backing up recording data to FTP server. Backup Interval: 1H・2H・6H・12H・24H・per file when the upload is succeeded, the file can be deleted automatically from device memory.

GRAPHTEC GLT400 Specifications

Number of Analog Terminal Units Up to 10 units (200 channels)
Sampling Speed 10 msec to 1 hour (Only voltage: 10 to 50 ms with limited channels), external (Able to select at only "STAND ALONE" mode)*1
*1The input/output cable for GL B-513 option (sold separately) is required to use the external I/O function.
Trigger/Alarm Function Repeat trigger: On/OFF

Trigger conditions: Start/Stop: Off, level value, alarm, external input, specified time, specified day of the week, certain time

Alarm judgment modes:
Combination: Analog, Logic or "AND"/"OR" of pulse
Analog judgment: H (↑), L (↓), Window In, Window Out Logic judgment: Pattern
Pulse judgment: H (↑), L (↓), Window In, Window Out

Operation of the alarm output function: Alarm lamp on device, email alarm notification, alarm output (4 channels ("REMOTE" 1 channel only)
Alarm output (hold function): Yes
External Input/Output*1 Input/output types: Trigger input (1 channel) or External sampling input (1 channel)/logic input (4 channels) or pulse input (4 channels), only for STAND-ALONE mode

Input specifications:
Input voltage range: 0 to 30 V (single-ended ground input)
Input signal: No-voltage contact (a-contact, b-contact, NO, NC), open collector, voltage input
Input threshold voltage: Approximately 2.5 V, hysteresis: Approximately 0.5 V (2.5 to 3 V)*7

Alarm output specifications:
Alarm output: 4 channel ("REMOTE" 1 channel only)
Output format: Open collector output (5 V, pull-up resistance 10 KΩ)

Collector-GND voltage: 50 V, collector current: 2 A, collector dissipation: 0.3 W
*1The input/output cable for GL B-513 option (sold separately) is required to use the external I/O function.
*7Switch between logic and pulse. Switch between trigger and external sampling.
Pulse Input Revolutions mode: This mode counts the number of pulses per sampling interval, and then converts them by multiplying the scaling factor to the RPM. Settable the number of pulses per revolution during revolution. Spans: 50, 500, 5000, 50 k, 500 k, 5 M, 50 M, 500 M RPM/F.S.

Counts mode: Displays a count of the number of pulses for each sampling interval from the start of measurement. Spans: 50, 500, 5000, 50 k, 500 k, 5 M, 50 M, 500 M C/F.S.

Inst. mode: Counts the number of pulses for each sampling interval. Resets the count value after each sampling interval. Spans: 50, 500, 5000, 50 k, 500 k, 5 M, 50 M, 500 M C/F.S.

Maximum number of pulse inputs:
Maximum input frequency: 50 kHz
Maximum number of count: 50 kC/sampling (16-bit counter)
Math Channels Computation types: +,-, ×, ÷ (Arithmetic) CH: Input channel (CH1 to 200)
Scaling Function(EU) 4 points can be set for each channel, temperature range: 2 points is available
Annotation Input Alphanumerics, number of characters: 31
Function: A comment can be input for each channel
PC I/F Types: Ethernet (10BASE-T/100BASE-TX), USB 2.0, wireless LAN option (sold separately)
Functions: Transfer device data to the PC, control device from PC, and connect as a remote terminal unit of GL840
Ethernet functions: Web server function, FTP server function, FTP client function, NTP client function, DHCP client function, DHCP server function, modbus/TCP communication
USB functions: USB drive mode: Transfer and delete the captured files in the internal memory or SD CARD
Realtime data transfer speed: 10 msec/1 channel maximum (*The transfer speed varies depends on the number of channels)
Memory Devices Internal memory: Approximately 4 GB
External memory slot: SD CARD slot: 1 (Compatible with SDHC, up to approximately 32 GB memory available)
Maximum size for 1 file: 1 file size is up to 2 GB
Memory contents: Setup conditions/measured data
Capture Function Functions: OFF, ring capturing, relay capturing
Ring capturing: If the number of recordings is exceeded "1000 to 2,000,000", capturing recording will continue on another file with deleting the oldest one. When ring capture is ON, the possible recording time becomes less.
Relay capturing: The captured data is continuously captured by files separated in the set relay unit without losing data
File format: GBD (Graphtec Binary Data) format/CSV format
Functions during capture: Replacement of SD CARD
Data Backup Function*2 Backup interval: OFF, 1, 2, 6, 12, 24 hours, each file
Backup destination: Internal memory, SD card, FTP
Data format: GBD·CSV
*2(Each file can be selected only when the backup destination is set to FTP and the captured file is deleted when the backup of the FTP client settings is activated normally)When the RING mode or external pulse synchronization sampling is selected for recording, the backup function is not available. When there are many active channels or the sampling time is fast or the backup interval is long, it may take time to close the data file after recording stops because the size of the data to be backed up becomes large. When saving file to FTP server using wireless LAN connection, backup may fail depending on the communication condition. Available sampling speed is 100 ms or slower when using the CSV format. When backup is enabled and data file format is specified as CSV format, SD memory card exchange (hot-swapping) and RELAY recording are not available.
Operating Environment -4 to 140°F (20 to 60°C) only when using B-564 or B-564SL (sold separately) input terminals and DC power
(0 to 45°C) when using B-565 (sold separately) input terminal or AC adapter
5 to 85% R.H. (non condensed)
(When using the USB PD as the power supply, the specification is based on power supply requirements)
Power Source AC adapter: AC 100~240V/50~60 Hz
DC power: 8.5 to 24 V DC (Maximum 26.4 V), requires option B-514 (sold separately)
USB PD: External USB PD compatible battery (USB power delivery revision 2.0 later), not supplied
Power Consumption Below 24 VA (when using the supplied AC adapter, AC100V)
Others Vibration: Automobile parts Type 1 Class A equivalent
Approximate Dimensions (Excluding Protrusions) Standard terminal B-564 (sold separately) or screwless terminal B-564SL (sold separately): 7.38 x 7.2 x 2.57" (187.5 × 183 × 65.5 mm)
Approximate Weight (Excluding AC Adapter) Standard terminal B-564 (sold separately) is attached: 2.4 lbs (1090 g)
Standard terminal B-564 (sold separately) is attached: 2.25 lbs (1020 g)
Withstand high-voltage high-precision terminal B-565 (sold separately) is attached: 2.47 lbs (1120 g)
Click here for complete specifications on the GRAPHTEC GLT400

What's included with the GRAPHTEC GLT400

  • Midi Multi-Use Data Logger
  • 3 x Spacers
  • AC Cable/AC Adapter
  • Quick Start Guide

Click on a category to view a selection of compatible accessories with the GRAPHTEC GLT400 Midi Multi-Use Data Logger.

GRAPHTEC B-513 Input/Output Cable for the GL series, 6.56', bare tips B-513
Compatible with the GL series data application software, the input/output cable has bare tips and a length of 6.56168' (2 m).




GRAPHTEC B-567-20 Extension Cable for the GL840 series, 6.56' B-567-20
Compatible with the GL840 series, this 6.56' (2 m) extension cable is an accessory.




GRAPHTEC B-567-05 Extension Cable for the GL840 series, 19.68" B-567-05
Compatible with the GL840, this 19.68" (50 cm) extension cable is an accessory.




GRAPHTEC B-566 Extension Terminal Base Unit for the GL840 series B-566
Compatible with the GL840 series, this extension terminal base unit allows you to add additional terminals up to 200 channels or 10 terminal blocks. In addition, the original terminal from the main body connects with this terminal base unit.




GRAPHTEC B-565 Screw Input Terminal Block for the GL840-WV and GLT400, 20 channels, withstand voltage type B-565
Compatible with the GL840-WV and GLT400, this input terminal block features 20 channels, high accuracy, high isolation, and can withstand high voltage.




GRAPHTEC B-564SL Screwless Input Terminal Block for the GL840-M and GLT400, 20 channels, multi-input type B-564SL
Compatible with the GL840-M and GLT400, this multi-input type screwless terminal block features 20 channels.




GRAPHTEC B-564 Screw Input Terminal Block for the GL840-M and GLT400, 20 channels, multi-input type B-564
Compatible with the GL840-M and GLT400, this multi-input type screw terminal block features 20 channels.




GRAPHTEC B-540 DIN Rail Bracket for the GLT400/B-566/GL840 B-540
Compatible with the GL840, GLT400, and B-566, this DIN rail bracket is an accessory.




GRAPHTEC ACADP-20 AC Adapter for the GL220/240/820/840/980/2000 with AC power cable (CE) ACADP-20
Compatible with the GL220, GL240, GL820, GL840, GL980, and GL2000, this AC adapter features a CE-rated AC power cable.




GRAPHTEC B-551 Shunt Resistor, 250 ohm B-551
Featuring a shunt resistance of 250 Ω, the shunt resistor is soldered on lugs for terminal block use.




GRAPHTEC B-530 Humidity Sensor, -25 to 80°C B-530
Comes with a 3 m length cable, the humidity sensor with a dedicated power connector has an allowable temperature range of -25 to 80°C.




GRAPHTEC B-568 Wireless LAN Unit for the GL840/GL240/GLT400 B-568
Compatible with the GL840 series, GL240, and GLT400, this wireless LAN unit is a wireless communication option.




Ask a question about GRAPHTEC GLT400 Midi Multi-Use Data Logger

Customer Reviews for the GRAPHTEC GLT400

More GRAPHTEC Products