Hioki 8967 Memory HiCorder Temperature Unit, 16-Bit Resolution

Model: 8967

Hioki 8967 Memory HiCorder Temperature Unit, 16-Bit Resolution

Model: 8967

Use this temperature module to measure temperature waveforms with your compatible Memory HiCorder. The isolated input allows for precise measurements.

Use this temperature module to measure temperature waveforms with your compatible Memory HiCorder. The isolated input allows for precise measurements.

Your Price $1496.00 USD
Availability 2 to 3 Weeks
Quantity

Hioki 8967 Offers



With this Hioki 8967 Memory HiCorder Temperature Unit connected to your compatible Memory HiCorder model, you'll be able to measure temperature waveforms with 16-bit A/D high resolution. Isolated input is capable of handling up to 300 VAC/VDC from the earth.

Features

  • Uses 16-bit A/D high resolution to measure temperature waveforms
  • Isolated input ensures accurate measurements
  • Designed to handle up to 300 VAC/VDC from the Earth
  • Compatible with Memory HiCorder MR6000, MR8847A, MR8827 and similar models (sold separately)

Hioki 8967 Specifications


Number of Channels2
Input ConnectorsPlug-in thermocouple connector
Maximum Rated Voltage to Earth300 VAC/VDC
Recommended Wire Diameter0.14 to 1.5 mm² (single wire), 0.14 to 1 mm² (braided wire), 0.18 mm minimum (conductor wire), AWG 26 to 16
Input Impedance5 MΩ (with line fault detection ON/OFF)
Temperature Measurement Range10°C/div: -148 to 392°F (-100 to 200°C), 50°C/div: -328 to 1,832°F (-200 to 1,000°C), 100°C/Div: -328 to 3632°F (-200 to 2,000°C)
Thermocouple TypeK, J, E, T, N, R, S, B, W
Thermocouple RangeK: -328 to 2,462°F (-200 to 1,350°C), J: -328 to 2,012°F (-200 to 1,100°C), E: -328 to 1,472°F (-200 to 800°C), T: -328 to 752°F (-200 to 400°C), N: -328 to 2,372°F (-200 to 1,300°C), R, S: 32 to 3,092°F (0 to 1,700°C), B: 752 to 3,272°F (400 to 1,800°C), W (WRe5-26): 32 to 3,632°F (0 to 2,000°C)
Data Refresh Rate1.2 ms (fast, digital filter off), 100 ms (normal, digital filter 50/60 Hz), 500 ms (slow, digital filter 10 Hz)
Measurement Accuracy±0.1% of full scale ±1°C (K, J, E, T, N thermocouples), ±0.1% of full scale ±3.5°C (R, S, W thermocouple at 0 to 400°C), ±0.1% of full scale ±3°C (R, S, W thermocouple at 400°C or more), ±0.1% of full scale ±3°C (B thermocouple at 400°C or more), ±1.5°C (reference junction compensation accuracy)
CE CompliantYes
Product Length8.05" (204.5 mm)
Product Width4.17" (106 mm)
Product Height0.78" (19.8 mm)
Product Weight8.5 oz (240 g)
Manufacturer Warranty3 years

What's included with the Hioki 8967


  • Temperature Unit
  • 2 x Ferrite Clamps

Ask a question about Hioki 8967 Memory HiCorder Temperature Unit, 16-Bit Resolution

Customer Reviews for the Hioki 8967

Hioki 8967 Offers



With this Hioki 8967 Memory HiCorder Temperature Unit connected to your compatible Memory HiCorder model, you'll be able to measure temperature waveforms with 16-bit A/D high resolution. Isolated input is capable of handling up to 300 VAC/VDC from the earth.

Features

  • Uses 16-bit A/D high resolution to measure temperature waveforms
  • Isolated input ensures accurate measurements
  • Designed to handle up to 300 VAC/VDC from the Earth
  • Compatible with Memory HiCorder MR6000, MR8847A, MR8827 and similar models (sold separately)

Hioki 8967 Specifications


Number of Channels2
Input ConnectorsPlug-in thermocouple connector
Maximum Rated Voltage to Earth300 VAC/VDC
Recommended Wire Diameter0.14 to 1.5 mm² (single wire), 0.14 to 1 mm² (braided wire), 0.18 mm minimum (conductor wire), AWG 26 to 16
Input Impedance5 MΩ (with line fault detection ON/OFF)
Temperature Measurement Range10°C/div: -148 to 392°F (-100 to 200°C), 50°C/div: -328 to 1,832°F (-200 to 1,000°C), 100°C/Div: -328 to 3632°F (-200 to 2,000°C)
Thermocouple TypeK, J, E, T, N, R, S, B, W
Thermocouple RangeK: -328 to 2,462°F (-200 to 1,350°C), J: -328 to 2,012°F (-200 to 1,100°C), E: -328 to 1,472°F (-200 to 800°C), T: -328 to 752°F (-200 to 400°C), N: -328 to 2,372°F (-200 to 1,300°C), R, S: 32 to 3,092°F (0 to 1,700°C), B: 752 to 3,272°F (400 to 1,800°C), W (WRe5-26): 32 to 3,632°F (0 to 2,000°C)
Data Refresh Rate1.2 ms (fast, digital filter off), 100 ms (normal, digital filter 50/60 Hz), 500 ms (slow, digital filter 10 Hz)
Measurement Accuracy±0.1% of full scale ±1°C (K, J, E, T, N thermocouples), ±0.1% of full scale ±3.5°C (R, S, W thermocouple at 0 to 400°C), ±0.1% of full scale ±3°C (R, S, W thermocouple at 400°C or more), ±0.1% of full scale ±3°C (B thermocouple at 400°C or more), ±1.5°C (reference junction compensation accuracy)
CE CompliantYes
Product Length8.05" (204.5 mm)
Product Width4.17" (106 mm)
Product Height0.78" (19.8 mm)
Product Weight8.5 oz (240 g)
Manufacturer Warranty3 years

What's included with the Hioki 8967


  • Temperature Unit
  • 2 x Ferrite Clamps

Ask a question about Hioki 8967 Memory HiCorder Temperature Unit, 16-Bit Resolution

Customer Reviews for the Hioki 8967

More Hioki Products

Calibration Lab