Use this temperature module to measure temperature waveforms with your compatible Memory HiCorder. The isolated input allows for precise measurements.
Use this temperature module to measure temperature waveforms with your compatible Memory HiCorder. The isolated input allows for precise measurements.
With this Hioki 8967 Memory HiCorder Temperature Unit connected to your compatible Memory HiCorder model, you'll be able to measure temperature waveforms with 16-bit A/D high resolution. Isolated input is capable of handling up to 300 VAC/VDC from the earth.
Features
Number of Channels | 2 |
Input Connectors | Plug-in thermocouple connector |
Maximum Rated Voltage to Earth | 300 VAC/VDC |
Recommended Wire Diameter | 0.14 to 1.5 mm² (single wire), 0.14 to 1 mm² (braided wire), 0.18 mm minimum (conductor wire), AWG 26 to 16 |
Input Impedance | 5 MΩ (with line fault detection ON/OFF) |
Temperature Measurement Range | 10°C/div: -148 to 392°F (-100 to 200°C), 50°C/div: -328 to 1,832°F (-200 to 1,000°C), 100°C/Div: -328 to 3632°F (-200 to 2,000°C) |
Thermocouple Type | K, J, E, T, N, R, S, B, W |
Thermocouple Range | K: -328 to 2,462°F (-200 to 1,350°C), J: -328 to 2,012°F (-200 to 1,100°C), E: -328 to 1,472°F (-200 to 800°C), T: -328 to 752°F (-200 to 400°C), N: -328 to 2,372°F (-200 to 1,300°C), R, S: 32 to 3,092°F (0 to 1,700°C), B: 752 to 3,272°F (400 to 1,800°C), W (WRe5-26): 32 to 3,632°F (0 to 2,000°C) |
Data Refresh Rate | 1.2 ms (fast, digital filter off), 100 ms (normal, digital filter 50/60 Hz), 500 ms (slow, digital filter 10 Hz) |
Measurement Accuracy | ±0.1% of full scale ±1°C (K, J, E, T, N thermocouples), ±0.1% of full scale ±3.5°C (R, S, W thermocouple at 0 to 400°C), ±0.1% of full scale ±3°C (R, S, W thermocouple at 400°C or more), ±0.1% of full scale ±3°C (B thermocouple at 400°C or more), ±1.5°C (reference junction compensation accuracy) |
CE Compliant | Yes |
Product Length | 8.05" (204.5 mm) |
Product Width | 4.17" (106 mm) |
Product Height | 0.78" (19.8 mm) |
Product Weight | 8.5 oz (240 g) |
Manufacturer Warranty | 3 years |
Number of Channels | 2 |
Input Connectors | Plug-in thermocouple connector |
Maximum Rated Voltage to Earth | 300 VAC/VDC |
Recommended Wire Diameter | 0.14 to 1.5 mm² (single wire), 0.14 to 1 mm² (braided wire), 0.18 mm minimum (conductor wire), AWG 26 to 16 |
Input Impedance | 5 MΩ (with line fault detection ON/OFF) |
Temperature Measurement Range | 10°C/div: -148 to 392°F (-100 to 200°C), 50°C/div: -328 to 1,832°F (-200 to 1,000°C), 100°C/Div: -328 to 3632°F (-200 to 2,000°C) |
Thermocouple Type | K, J, E, T, N, R, S, B, W |
Thermocouple Range | K: -328 to 2,462°F (-200 to 1,350°C), J: -328 to 2,012°F (-200 to 1,100°C), E: -328 to 1,472°F (-200 to 800°C), T: -328 to 752°F (-200 to 400°C), N: -328 to 2,372°F (-200 to 1,300°C), R, S: 32 to 3,092°F (0 to 1,700°C), B: 752 to 3,272°F (400 to 1,800°C), W (WRe5-26): 32 to 3,632°F (0 to 2,000°C) |
Data Refresh Rate | 1.2 ms (fast, digital filter off), 100 ms (normal, digital filter 50/60 Hz), 500 ms (slow, digital filter 10 Hz) |
Measurement Accuracy | ±0.1% of full scale ±1°C (K, J, E, T, N thermocouples), ±0.1% of full scale ±3.5°C (R, S, W thermocouple at 0 to 400°C), ±0.1% of full scale ±3°C (R, S, W thermocouple at 400°C or more), ±0.1% of full scale ±3°C (B thermocouple at 400°C or more), ±1.5°C (reference junction compensation accuracy) |
CE Compliant | Yes |
Product Length | 8.05" (204.5 mm) |
Product Width | 4.17" (106 mm) |
Product Height | 0.78" (19.8 mm) |
Product Weight | 8.5 oz (240 g) |
Manufacturer Warranty | 3 years |