World's premier digital multimeter. Superior accuracy and high Response, topped with safety terminal shutters.
World's premier digital multimeter. Superior accuracy and high Response, topped with safety terminal shutters.
The Hioki DT4282 Digital Multimeter is ideal for maintenance inspections of buildings and manufacturing plant equipment, as well as research and develoment work and maintenance inspections of inverters, solar power systems, fuel cells, and electric vehicles.
Features
DC Voltage | |
Range | 60 mV to 1000 V |
Accuracy | 60 mV: ±0.2% rdg. ±25 dgt. 600 mV: ±0.025% rdg. ±5 dgt. 6 V: ±0.025% rdg. ±2 dgt. 60 V: ±0.025% rdg. ±2 dgt. 600 V: ±0.03% rdg. ±2 dgt. 1000 V: ±0.03% rdg. ±2 dgt. |
Input Impedance | 60 mV: 1 GΩ or more: 100 pF or less 600 mV: 1 GΩ or more: 100 pF or less 6 V: 11 MΩ ±2% : 100 pF or less 60 V: 10.3 MΩ ±2% : 100 pF or less 600 V: 10.2 MΩ ±2% : 100 pF or less 1000 V: 10.2 MΩ ±2% : 100 pF or less |
DCA Measurement | |
Range | 600 μA to 10 A |
Accuracy | 600 μA: ±0.05% rdg. ±25 dgt. 6000 μA: ±0.05% rdg. ±5 dgt. 60 mA: ±0.05% rdg. ±25 dgt. 600 mA: ±0.15% rdg. ±5 dgt. 6 A: ±0.2% rdg. ±25 dgt. 10 A: ±0.2% rdg. ±5 dgt. |
Shunt Resistance | 600 to 6000 μA: 101 Ω 60 to 600 mA: 1 Ω 6 to 10 A: 10 mΩ |
Resistance Measurement | |
Range | 60 Ω to 600 mΩ |
Accuracy | 60 Ω: ±0.3% rdg. ±20 dgt. 600 Ω: ±0.03% rdg. ±10 dgt. 6 to 60 kΩ: ±0.03% rdg. ±2 dgt. 600 kΩ: ±0.03% rdg. ±2 dgt. 6 MΩ: ±0.15% rdg. ±4 dgt. 60 MΩ: ±1.5% rdg. ±10 dgt. 600 MΩ: ±3.0% rdg. ±20 dgt. & ±8.0% rdg. ±20 dgt. |
Measurement Current | 60 to 600 Ω: 640 μA ±10% 6 kΩ: 96 μA ±10% 60 kΩ: 9.3 μA ±10% 600 kΩ: 0.96 μA ±10% 6 to 600 MΩ: 96 nA ±10% |
Open-Terminal Voltage | 2.5V DC or less |
Continuity Check | |
Range | 600.0 Ω |
Accuracy | ±0.5% rdg. ±5 dgt. |
Measurement Current | 640 μA ±10% |
Open-Terminal Voltage | 2.5 V DC or less |
Electrostatic Capacity | |
Range | 1 nF to 100 mF |
Accuracy | 1 nF: ±1.0% rdg. ±20 dgt. 10 nF to 1 μF: ±1.0% rdg. ±5 dgt. 10 μF to 10 mF: ±2.0% rdg. ±5 dgt. 100 mF: ±2.0% rdg. ±20 dgt |
Measurement Current | 1 nF to 1 μF: 32 μA ±10% 10 μF to 100 mF: 680 μA ±10% |
Open-Circuit Voltage | 1 nF to 1 μF: DC2.5 V or less 10 to 100 μF: DC3.1 V or less 1 to 100 mF: DC2.1 V or less |
DC Voltage | |
Range | 60 mV to 1000 V |
Accuracy | 60 mV: ±0.2% rdg. ±25 dgt. 600 mV: ±0.025% rdg. ±5 dgt. 6 V: ±0.025% rdg. ±2 dgt. 60 V: ±0.025% rdg. ±2 dgt. 600 V: ±0.03% rdg. ±2 dgt. 1000 V: ±0.03% rdg. ±2 dgt. |
Input Impedance | 60 mV: 1 GΩ or more: 100 pF or less 600 mV: 1 GΩ or more: 100 pF or less 6 V: 11 MΩ ±2% : 100 pF or less 60 V: 10.3 MΩ ±2% : 100 pF or less 600 V: 10.2 MΩ ±2% : 100 pF or less 1000 V: 10.2 MΩ ±2% : 100 pF or less |
DCA Measurement | |
Range | 600 μA to 10 A |
Accuracy | 600 μA: ±0.05% rdg. ±25 dgt. 6000 μA: ±0.05% rdg. ±5 dgt. 60 mA: ±0.05% rdg. ±25 dgt. 600 mA: ±0.15% rdg. ±5 dgt. 6 A: ±0.2% rdg. ±25 dgt. 10 A: ±0.2% rdg. ±5 dgt. |
Shunt Resistance | 600 to 6000 μA: 101 Ω 60 to 600 mA: 1 Ω 6 to 10 A: 10 mΩ |
Resistance Measurement | |
Range | 60 Ω to 600 mΩ |
Accuracy | 60 Ω: ±0.3% rdg. ±20 dgt. 600 Ω: ±0.03% rdg. ±10 dgt. 6 to 60 kΩ: ±0.03% rdg. ±2 dgt. 600 kΩ: ±0.03% rdg. ±2 dgt. 6 MΩ: ±0.15% rdg. ±4 dgt. 60 MΩ: ±1.5% rdg. ±10 dgt. 600 MΩ: ±3.0% rdg. ±20 dgt. & ±8.0% rdg. ±20 dgt. |
Measurement Current | 60 to 600 Ω: 640 μA ±10% 6 kΩ: 96 μA ±10% 60 kΩ: 9.3 μA ±10% 600 kΩ: 0.96 μA ±10% 6 to 600 MΩ: 96 nA ±10% |
Open-Terminal Voltage | 2.5V DC or less |
Continuity Check | |
Range | 600.0 Ω |
Accuracy | ±0.5% rdg. ±5 dgt. |
Measurement Current | 640 μA ±10% |
Open-Terminal Voltage | 2.5 V DC or less |
Electrostatic Capacity | |
Range | 1 nF to 100 mF |
Accuracy | 1 nF: ±1.0% rdg. ±20 dgt. 10 nF to 1 μF: ±1.0% rdg. ±5 dgt. 10 μF to 10 mF: ±2.0% rdg. ±5 dgt. 100 mF: ±2.0% rdg. ±20 dgt |
Measurement Current | 1 nF to 1 μF: 32 μA ±10% 10 μF to 100 mF: 680 μA ±10% |
Open-Circuit Voltage | 1 nF to 1 μF: DC2.5 V or less 10 to 100 μF: DC3.1 V or less 1 to 100 mF: DC2.1 V or less |