FREE SHIPPING ON ONLINE ORDERS OVER $99*

Hioki DT4282 Digital Multimeter

Model: DT4282

Hioki DT4282 Digital Multimeter

Model: DT4282

World's premier digital multimeter. Superior accuracy and high Response, topped with safety terminal shutters.

World's premier digital multimeter. Superior accuracy and high Response, topped with safety terminal shutters.

Your Price $574.00 USD
Availability 3 to 4 Weeks
Quantity

Traceable In-House Calibration Certificate for your DT4282 Digital Multimeter

Traceable In-House Calibration Certificate for your DT4282 Digital Multimeter

Hioki DT4282 Offers

The Hioki DT4282 Digital Multimeter is ideal for maintenance inspections of buildings and manufacturing plant equipment, as well as research and develoment work and maintenance inspections of inverters, solar power systems, fuel cells, and electric vehicles.

Features

  • Improved response for more efficient measurement--The DT4281 and DT4282 deliver the fastest response speed of any portable multimeter, improving the response time for DC measurement from previous models’ 1.5 seconds to 1.0 seconds. They also offer exceptional noise resistance and yield stable measurement results immediately after measurement. Faster measurement lets technicians perform their tasks at a higher level of efficiency. Thanks to safety performance that allows use in applications up to CAT IV (600 V), the most demanding measurement category, and an operating temperature range of -15 to 55°C, the instruments are safe and 100% reliable.
  • High-accuracy, broadband measurement--With basic accuracy of ±0.025% for DC voltage measurement and a frequency band of 20 to 100 kHz for AC voltage measurement, the DT4281 and DT4282 deliver the highest accuracy and widest frequency band of any portable multimeter. Since measured values are true RMS values, both units’ indicated measurements are accurate, even when measuring a distorted waveform. Their ability to conduct high-accuracy, wideband measurement makes them ideal for use not only in the field, but also in research and development work, where high performance is a must. Previous true RMS-type instruments were unable to measure voltage on the secondary side of an inverter, but the DT4281 and DT4282 incorporate a low-pass filter function that enables them to make such measurements by eliminating the carrier frequency component. In this way, these instruments also serve as useful tools in inverter research and development.
  • Terminal shutter mechanism designed to prevent mistaken test lead insertion--Because digital multimeters can measure numerous parameters such as voltage, current, and resistance, they have multiple input terminals, making it possible to insert measurement leads improperly. Such a mistake could cause equipment damage by allowing the wrong electrical signals to be input to the instrument. To prevent erroneous connections, the DT4281 and DT4282 incorporate a shutter designed so that only the terminals needed for the measurement parameter in use are exposed when the user turns a rotary switch. This terminal shutter mechanism helps ensure proper insertion of measurement leads. HIOKI offers an extensive selection of measurement leads for different applications, boosting users’ ability to perform measurement in a way that meets their specific needs.
  • Backlit display to enable use in dark locations--Both the DT4281 and the DT4282 feature a backlit screen. The white backlight is activated by pressing a display button, allowing measured values to be read accurately, even in dark locations. Additionally, the display will turn red if a voltage of 1,000 V AC/DC or greater is input to the instrument, providing an easy-to-understand warning of a potentially hazardous situation.
  • Internal memory capable of storing up to 400 data points for increased measurement efficiency in on-site maintenance work--Both the DT4281 and the DT4282 can store up to 400 data points. This capability dramatically boosts work efficiency when performing a large number of measurements, for example in battery maintenance work. Additionally, the optional communications package can be used to download measurement data to a computer or save graph displays and data in real time.
  • Shock-resistant, drop-proof design--Both the DT4281 and the DT4282 feature a drop-proof design capable of withstanding a 1-meter fall onto a concrete surface.
  • Support for clamp sensors (DT4281 only)--The DT4281 can perform non-contact current measurement when used in combination with an optional clamp sensor

Hioki DT4282 Specifications


DC Voltage
Range 60 mV to 1000 V
Accuracy 60 mV: ±0.2% rdg. ±25 dgt.
600 mV: ±0.025% rdg. ±5 dgt.
6 V: ±0.025% rdg. ±2 dgt.
60 V: ±0.025% rdg. ±2 dgt.
600 V: ±0.03% rdg. ±2 dgt.
1000 V: ±0.03% rdg. ±2 dgt.
Input Impedance 60 mV: 1 GΩ or more: 100 pF or less
600 mV: 1 GΩ or more: 100 pF or less
6 V: 11 MΩ ±2% : 100 pF or less
60 V: 10.3 MΩ ±2% : 100 pF or less
600 V: 10.2 MΩ ±2% : 100 pF or less
1000 V: 10.2 MΩ ±2% : 100 pF or less
DCA Measurement
Range 600 μA to 10 A
Accuracy 600 μA: ±0.05% rdg. ±25 dgt.
6000 μA: ±0.05% rdg. ±5 dgt.
60 mA: ±0.05% rdg. ±25 dgt.
600 mA: ±0.15% rdg. ±5 dgt.
6 A: ±0.2% rdg. ±25 dgt.
10 A: ±0.2% rdg. ±5 dgt.
Shunt Resistance 600 to 6000 μA: 101 Ω
60 to 600 mA: 1 Ω 6 to 10 A: 10 mΩ
Resistance Measurement
Range 60 Ω to 600 mΩ
Accuracy 60 Ω: ±0.3% rdg. ±20 dgt.
600 Ω: ±0.03% rdg. ±10 dgt.
6 to 60 kΩ: ±0.03% rdg. ±2 dgt.
600 kΩ: ±0.03% rdg. ±2 dgt.
6 MΩ: ±0.15% rdg. ±4 dgt.
60 MΩ: ±1.5% rdg. ±10 dgt.
600 MΩ: ±3.0% rdg. ±20 dgt. & ±8.0% rdg. ±20 dgt.
Measurement Current 60 to 600 Ω: 640 μA ±10%
6 kΩ: 96 μA ±10%
60 kΩ: 9.3 μA ±10%
600 kΩ: 0.96 μA ±10%
6 to 600 MΩ: 96 nA ±10%
Open-Terminal Voltage 2.5V DC or less
Continuity Check
Range 600.0 Ω
Accuracy ±0.5% rdg. ±5 dgt.
Measurement Current 640 μA ±10%
Open-Terminal Voltage 2.5 V DC or less
Electrostatic Capacity
Range 1 nF to 100 mF
Accuracy 1 nF: ±1.0% rdg. ±20 dgt.
10 nF to 1 μF: ±1.0% rdg. ±5 dgt.
10 μF to 10 mF: ±2.0% rdg. ±5 dgt.
100 mF: ±2.0% rdg. ±20 dgt
Measurement Current 1 nF to 1 μF: 32 μA ±10%
10 μF to 100 mF: 680 μA ±10%
Open-Circuit Voltage 1 nF to 1 μF: DC2.5 V or less
10 to 100 μF: DC3.1 V or less
1 to 100 mF: DC2.1 V or less
Click here for complete specifications on the Hioki DT4282

What's included with the Hioki DT4282

  • Digital Multimeter
  • Test Lead
  • Instruction Manual
  • 4 x LR6 Batteries

Ask a question about Hioki DT4282 Digital Multimeter

Customer Reviews for the Hioki DT4282

Hioki DT4282 Offers

The Hioki DT4282 Digital Multimeter is ideal for maintenance inspections of buildings and manufacturing plant equipment, as well as research and develoment work and maintenance inspections of inverters, solar power systems, fuel cells, and electric vehicles.

Features

  • Improved response for more efficient measurement--The DT4281 and DT4282 deliver the fastest response speed of any portable multimeter, improving the response time for DC measurement from previous models’ 1.5 seconds to 1.0 seconds. They also offer exceptional noise resistance and yield stable measurement results immediately after measurement. Faster measurement lets technicians perform their tasks at a higher level of efficiency. Thanks to safety performance that allows use in applications up to CAT IV (600 V), the most demanding measurement category, and an operating temperature range of -15 to 55°C, the instruments are safe and 100% reliable.
  • High-accuracy, broadband measurement--With basic accuracy of ±0.025% for DC voltage measurement and a frequency band of 20 to 100 kHz for AC voltage measurement, the DT4281 and DT4282 deliver the highest accuracy and widest frequency band of any portable multimeter. Since measured values are true RMS values, both units’ indicated measurements are accurate, even when measuring a distorted waveform. Their ability to conduct high-accuracy, wideband measurement makes them ideal for use not only in the field, but also in research and development work, where high performance is a must. Previous true RMS-type instruments were unable to measure voltage on the secondary side of an inverter, but the DT4281 and DT4282 incorporate a low-pass filter function that enables them to make such measurements by eliminating the carrier frequency component. In this way, these instruments also serve as useful tools in inverter research and development.
  • Terminal shutter mechanism designed to prevent mistaken test lead insertion--Because digital multimeters can measure numerous parameters such as voltage, current, and resistance, they have multiple input terminals, making it possible to insert measurement leads improperly. Such a mistake could cause equipment damage by allowing the wrong electrical signals to be input to the instrument. To prevent erroneous connections, the DT4281 and DT4282 incorporate a shutter designed so that only the terminals needed for the measurement parameter in use are exposed when the user turns a rotary switch. This terminal shutter mechanism helps ensure proper insertion of measurement leads. HIOKI offers an extensive selection of measurement leads for different applications, boosting users’ ability to perform measurement in a way that meets their specific needs.
  • Backlit display to enable use in dark locations--Both the DT4281 and the DT4282 feature a backlit screen. The white backlight is activated by pressing a display button, allowing measured values to be read accurately, even in dark locations. Additionally, the display will turn red if a voltage of 1,000 V AC/DC or greater is input to the instrument, providing an easy-to-understand warning of a potentially hazardous situation.
  • Internal memory capable of storing up to 400 data points for increased measurement efficiency in on-site maintenance work--Both the DT4281 and the DT4282 can store up to 400 data points. This capability dramatically boosts work efficiency when performing a large number of measurements, for example in battery maintenance work. Additionally, the optional communications package can be used to download measurement data to a computer or save graph displays and data in real time.
  • Shock-resistant, drop-proof design--Both the DT4281 and the DT4282 feature a drop-proof design capable of withstanding a 1-meter fall onto a concrete surface.
  • Support for clamp sensors (DT4281 only)--The DT4281 can perform non-contact current measurement when used in combination with an optional clamp sensor

Hioki DT4282 Specifications


DC Voltage
Range 60 mV to 1000 V
Accuracy 60 mV: ±0.2% rdg. ±25 dgt.
600 mV: ±0.025% rdg. ±5 dgt.
6 V: ±0.025% rdg. ±2 dgt.
60 V: ±0.025% rdg. ±2 dgt.
600 V: ±0.03% rdg. ±2 dgt.
1000 V: ±0.03% rdg. ±2 dgt.
Input Impedance 60 mV: 1 GΩ or more: 100 pF or less
600 mV: 1 GΩ or more: 100 pF or less
6 V: 11 MΩ ±2% : 100 pF or less
60 V: 10.3 MΩ ±2% : 100 pF or less
600 V: 10.2 MΩ ±2% : 100 pF or less
1000 V: 10.2 MΩ ±2% : 100 pF or less
DCA Measurement
Range 600 μA to 10 A
Accuracy 600 μA: ±0.05% rdg. ±25 dgt.
6000 μA: ±0.05% rdg. ±5 dgt.
60 mA: ±0.05% rdg. ±25 dgt.
600 mA: ±0.15% rdg. ±5 dgt.
6 A: ±0.2% rdg. ±25 dgt.
10 A: ±0.2% rdg. ±5 dgt.
Shunt Resistance 600 to 6000 μA: 101 Ω
60 to 600 mA: 1 Ω 6 to 10 A: 10 mΩ
Resistance Measurement
Range 60 Ω to 600 mΩ
Accuracy 60 Ω: ±0.3% rdg. ±20 dgt.
600 Ω: ±0.03% rdg. ±10 dgt.
6 to 60 kΩ: ±0.03% rdg. ±2 dgt.
600 kΩ: ±0.03% rdg. ±2 dgt.
6 MΩ: ±0.15% rdg. ±4 dgt.
60 MΩ: ±1.5% rdg. ±10 dgt.
600 MΩ: ±3.0% rdg. ±20 dgt. & ±8.0% rdg. ±20 dgt.
Measurement Current 60 to 600 Ω: 640 μA ±10%
6 kΩ: 96 μA ±10%
60 kΩ: 9.3 μA ±10%
600 kΩ: 0.96 μA ±10%
6 to 600 MΩ: 96 nA ±10%
Open-Terminal Voltage 2.5V DC or less
Continuity Check
Range 600.0 Ω
Accuracy ±0.5% rdg. ±5 dgt.
Measurement Current 640 μA ±10%
Open-Terminal Voltage 2.5 V DC or less
Electrostatic Capacity
Range 1 nF to 100 mF
Accuracy 1 nF: ±1.0% rdg. ±20 dgt.
10 nF to 1 μF: ±1.0% rdg. ±5 dgt.
10 μF to 10 mF: ±2.0% rdg. ±5 dgt.
100 mF: ±2.0% rdg. ±20 dgt
Measurement Current 1 nF to 1 μF: 32 μA ±10%
10 μF to 100 mF: 680 μA ±10%
Open-Circuit Voltage 1 nF to 1 μF: DC2.5 V or less
10 to 100 μF: DC3.1 V or less
1 to 100 mF: DC2.1 V or less
Click here for complete specifications on the Hioki DT4282

What's included with the Hioki DT4282

  • Digital Multimeter
  • Test Lead
  • Instruction Manual
  • 4 x LR6 Batteries

Ask a question about Hioki DT4282 Digital Multimeter

Customer Reviews for the Hioki DT4282

More Hioki Products

Calibration Lab