Hioki IM3570 Impedance Analyzer

Model: IM3570

Hioki IM3570 Impedance Analyzer

Model: IM3570

The impedance analyzer is ideal for use in applications requiring low-ESR measurement on the order of several milliohms, such as the testing of functional polymer capacitors, due to its superior low-impedance repeatability.

The impedance analyzer is ideal for use in applications requiring low-ESR measurement on the order of several milliohms, such as the testing of functional polymer capacitors, due to its superior low-impedance repeatability.

Your Price $10995.00 USD
Availability 4 to 5 Weeks
Quantity

Hioki IM3570 Impedance Analyzer

  • LCR measurement, DCR measurement, sweep measurement, continuous measurement and high-speed testing achieved with one instrument
  • High-speed testing, achieving maximum speeds of 1.5ms (1kHz) and 0.5ms) (100kHz) in LCR mode
  • High accuracy measurements, basic accuracy of Z parameter: +/- 0.08%
  • Perfect impedance analyzer for testing the reasonable characteristics of piezoelectric elements, C-D and low ESR measurement of functional polymer capacitors, DCR and L-Q measurement of inductors (coils and transformers)
  • Perform frequency sweeps, level sweeps, and time interval measurements in analyzer mode

Hioki IM3570 Specifications

Measurement
Modes LCR mode, Analyzer mode (Sweeps with measurement frequency and measurement level), Continuous measurement mode
Parameters Z, Y, θ, Rs (ESR), Rp, Rdc (DC resistance), X, G, B, Cs, Cp, Ls, Lp, D (tanδ), Q
Range 100 mΩ to 100 MΩ, 12 ranges (All parameters are determined according to Z)
Frequency 4 Hz to 5 MHz (5 digits setting resolution, minimum resolution 10 mHz)
Signal Level Normal mode: V mode/CV mode: 5 mV to 5 Vrms (up to 1 MHz)
10 mV to 1 Vrms (1.0001 to 5 MHz), 1 mVrms steps
CC mode: 10 μA to 50 mArms (up to 1 MHz)
10 μA to 10 mArms (1.0001 to 5 MHz), 10 μArms steps
Low impedance high accuracy mode: V mode/CV mode: 5 mV to 1 Vrms (up to 100 kHz), 1 mVrms steps
CC mode:10 μA to 100 mArms (100 mΩ and 1Ω ranges of up to 100 kHz), 10 μArms steps
Time 0.5 ms (100 kHz, FAST, display OFF, representative value)
General Specifications
Display Range Z, Y, Rs, Rp, Rdc, X, G, B, Ls, Lp, Cs, Cp :
±(0.000000 [unit] to 9.999999G [unit], Absolute value display for Z and Y only
θ : ±(0.000° to 180.000°), D : ±(0.000000 to 9.999999)
Q : ±(0.00 to 99999.99), Δ % : ±(0.0000% to 999.9999%)
Basic Accuracy Z ±0.08% rdg. θ: ±0.05°
Output Impedance Normal mode: 100 Ω, low impedance high accuracy mode: 10 Ω
Display 5.7" color TFT, display can be set to ON/OFF
Functions DC bias measurement, comparator, BIN measurement (classification), panel loading/saving, memory function
Interfaces EXT I/O (handler), RS-232C, GP-IB, USB communication, USB memory, LAN
Power Supply 90 to 264 V AC, 50/60 Hz, 150 VA maximum
Dimensions 12.99 x 4.69 x 12.09" (330 x 119 x 307 mm)
Weight 204.6 oz (5.8 kg)
Click here for complete specifications on the Hioki IM3570

What's included with the Hioki IM3570

  • Impedance Analyzer
  • Power Cord
  • Instruction Manual
  • PC Communication Manual (CD-R)

Ask a question about Hioki IM3570 Impedance Analyzer

Customer Reviews for the Hioki IM3570

Hioki IM3570 Impedance Analyzer

  • LCR measurement, DCR measurement, sweep measurement, continuous measurement and high-speed testing achieved with one instrument
  • High-speed testing, achieving maximum speeds of 1.5ms (1kHz) and 0.5ms) (100kHz) in LCR mode
  • High accuracy measurements, basic accuracy of Z parameter: +/- 0.08%
  • Perfect impedance analyzer for testing the reasonable characteristics of piezoelectric elements, C-D and low ESR measurement of functional polymer capacitors, DCR and L-Q measurement of inductors (coils and transformers)
  • Perform frequency sweeps, level sweeps, and time interval measurements in analyzer mode

Hioki IM3570 Specifications

Measurement
Modes LCR mode, Analyzer mode (Sweeps with measurement frequency and measurement level), Continuous measurement mode
Parameters Z, Y, θ, Rs (ESR), Rp, Rdc (DC resistance), X, G, B, Cs, Cp, Ls, Lp, D (tanδ), Q
Range 100 mΩ to 100 MΩ, 12 ranges (All parameters are determined according to Z)
Frequency 4 Hz to 5 MHz (5 digits setting resolution, minimum resolution 10 mHz)
Signal Level Normal mode: V mode/CV mode: 5 mV to 5 Vrms (up to 1 MHz)
10 mV to 1 Vrms (1.0001 to 5 MHz), 1 mVrms steps
CC mode: 10 μA to 50 mArms (up to 1 MHz)
10 μA to 10 mArms (1.0001 to 5 MHz), 10 μArms steps
Low impedance high accuracy mode: V mode/CV mode: 5 mV to 1 Vrms (up to 100 kHz), 1 mVrms steps
CC mode:10 μA to 100 mArms (100 mΩ and 1Ω ranges of up to 100 kHz), 10 μArms steps
Time 0.5 ms (100 kHz, FAST, display OFF, representative value)
General Specifications
Display Range Z, Y, Rs, Rp, Rdc, X, G, B, Ls, Lp, Cs, Cp :
±(0.000000 [unit] to 9.999999G [unit], Absolute value display for Z and Y only
θ : ±(0.000° to 180.000°), D : ±(0.000000 to 9.999999)
Q : ±(0.00 to 99999.99), Δ % : ±(0.0000% to 999.9999%)
Basic Accuracy Z ±0.08% rdg. θ: ±0.05°
Output Impedance Normal mode: 100 Ω, low impedance high accuracy mode: 10 Ω
Display 5.7" color TFT, display can be set to ON/OFF
Functions DC bias measurement, comparator, BIN measurement (classification), panel loading/saving, memory function
Interfaces EXT I/O (handler), RS-232C, GP-IB, USB communication, USB memory, LAN
Power Supply 90 to 264 V AC, 50/60 Hz, 150 VA maximum
Dimensions 12.99 x 4.69 x 12.09" (330 x 119 x 307 mm)
Weight 204.6 oz (5.8 kg)
Click here for complete specifications on the Hioki IM3570

What's included with the Hioki IM3570

  • Impedance Analyzer
  • Power Cord
  • Instruction Manual
  • PC Communication Manual (CD-R)

Ask a question about Hioki IM3570 Impedance Analyzer

Customer Reviews for the Hioki IM3570

More Hioki Products

Calibration Lab