Hioki PQ3100-04/6000 Power Quality Analyzer Kit, Custom 4 Clamp AC Flexible Current Sensor, 6000A

Model: PQ3100-04/6000 | Order No: PQ3100-04/6000 KIT

Hioki PQ3100-04/6000 Power Quality Analyzer Kit, Custom 4 Clamp AC Flexible Current Sensor, 6000A

Model: PQ3100-04/6000 | Order No: PQ3100-04/6000 KIT

THE BEST IN CLASS - Power Measuring Instrument for measuring single to three phase lines with a high degree of precision and accuracy. The PQ3100 is a comprehensive but easy-to-use power quality analyzer for monitoring and recording power supply anomalies, and also for assessing power supply problems such as voltage drops, flicker, harmonics and other electrical issues. The Value kit is supplied with 4 Flexible AC (600A) current sensors.

THE BEST IN CLASS - Power Measuring Instrument for measuring single to three phase lines with a high degree of precision and accuracy. The PQ3100 is a comprehensive but easy-to-use power quality analyzer for monitoring and recording power supply anomalies, and also for assessing power supply problems such as voltage drops, flicker, harmonics and other electrical issues. The Value kit is supplied with 4 Flexible AC (600A) current sensors.

Your Price $5326.00 USD
Availability 5 to 6 Weeks
Quantity

Hioki PQ3100-04/6000 Offers

Features

  • Record data including voltage, current, power, harmonics, and flicker simultaneously along a single time axis (Flicker recording available in future firmware update)
  • Capture all power anomalies, including instantaneous outages, voltage drops, and frequency fluctuations, while simultaneously recording trend data
  • Quick Set: Easy-to-understand on-screen guide for measurement procedures
  • Bundled PQ ONE application software makes it easy to create reports
  • Record waveforms for up to 1 second before and 10 seconds after an anomaly occurs
  • Accurately measure DC currents over extended periods of time (with an AC/DC auto-zero current sensor)
  • Directly supply power to connected current sensors

Reliable Power Supply Maintenance, Management, Troubleshooting, and Analysis

The power grid is the single most important piece of infrastructure in our society, and regular maintenance and management are essential in order to prevent problems. When power supply issues are caused by factors such as equipment malfunctions or rapid surges in power demand, personnel are called upon to analyze the underlying causes quickly and precisely. The PQ3100 aids in reliable power analysis by delivering analytical capabilities that reliably captures the full range of power anomalies along with exceptional ease of use that facilitates each step of instrument operation, from connecting it to the circuit to recording data.

Recording the Power Quality of a Power Grid

The PQ3100 records data including voltage, current, power, harmonics, and flicker* simultaneously along a single time axis, and the included PQ ONE application software makes it easy to create reports.

Measure all power parameters including voltage, current, power, harmonics, and flicker simultaneously along the same time axis, giving it the ability to capture all power anomalies such as intermittent power interruptions, voltage drops and frequency fluctuations while recording the power trend.



Analyzing Device Power Supply Issues

When you need to resolve issues with a device that unexpectedly malfunctions or suddenly stops, the PQ3100 captures all power anomalies, including instantaneous outages, voltage drops, and frequency fluctuations, while simultaneously recording trend data



Measuring AC/DC Power

Used in combination with an AC/DC auto-zero current sensor, the PQ3100 can accurately measure DC currents over extended periods of time. Since the instrument supplies power to connected sensors, there's no need to use an additional power supply for sensors.



Measuring all Parameters at the Same Time

The PQ3100 makes it easy to verify current conditions by displaying all measurement parameters simple by toggling the screens.



Simultaneously Recording Trend Graphs and Event Waveforms

The PQ3100 records trend data for all parameters at once. When the PQA detects a power anomaly, the event is immediately recorded. Since maximum, minimum, and average values are recorded during each interval, you'll never miss peak values.



Manage Power Quality with Greater Convenience of the PQ ONE Bundled Application

The included PQ ONE application software for the PQ3100 Power Quality Analyzer lets you analyze captured data in fine detail and create regular power quality management reports with ease and flexibility. Investigate the cause of power anomalies in the comfort of your office using your PC.

A Simple Solution to Wiring and Configuration

Provides an intuitive QUICK SET navigation system to simplify the wiring and configuration procedures for measuring a 3-phase system. Connection mistakes such as reversing the direction of the clamp sensor or phase order are automatically detected along with suggestions on how to correct the setup.

Hioki PQ3100-04/6000 Specifications

Measurement line type Single-phase 2-wire, Single-phase 3-wire, Three-phase 3-wire or Three-phase 4-wire plus one extra input channel CH4 for voltage/current, (all channels AC/DC measurement)
Voltage ranges Voltage measurement: 1000.0 V rms or DC, Transient measurement 2.200 kV peak
Current ranges 50.000 mA AC to 5.0000 kA AC, 10.000 A DC to 2.0000 kA DC (depends on current sensor in use)
Power ranges 50.000 W to 6.0000 MW (determined automatically based on current range in use)
Basic accuracy Voltage: ±0.2% of nominal voltage, Current: ±0.1 % rdg. ±0.1 % f.s. + current sensor accuracy, Active power: DC ±0.5 % rdg. ±0.5 % f.s. + current sensor accuracy, AC ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy
Record Maximum recording interval: 1 year, Maximum number of recordable events: 9999 × 365 days
Interfaces SD/SDHC card, RS-232C (for communication/LR8410 link, available in future firmware update), LAN (HTTP server/FTP/send e-mail, available in future firmware update), USB 2.0 (for communication)
Display 6.5-inch TFT color LCD (640 × 480 dots)
Power supply AC adapter Z1002 (100 V to 240 V AC, 50/60 Hz, rated current 1.7 A), Battery pack Z1003 (Continuous use: 8 hr, Charging time: Max. 5 hr 30 m with AC adapter)
Dimensions and mass 300 mm (11.81 in)W × 211 mm (8.31 in)H × 68 mm (2.68 in)D, 2.5 kg (88.2 oz) (including battery pack)
Click here for complete specifications on the Hioki PQ3100-04/6000

What's included with the Hioki PQ3100-04/6000

  • Hioki PQ3100-01/600 Power Quality Analyzer Kit, Custom 4 Clamp, 6000A
  • AC Flexible Current Sensor CT7045 (4)
  • Carrying Case C1009
  • SD Memory Card 2GB Z4001
  • Instruction Manual
  • Measurement Guide
  • Voltage Cord L1000-05
  • Spiral Tube
  • AC Adapter Z1002
  • Strap
  • USB Cable
  • Battery Pack Z1003

Ask a question about Hioki PQ3100-04/6000 Power Quality Analyzer Kit, Custom 4 Clamp AC Flexible Current Sensor, 6000A

Customer Reviews for the Hioki PQ3100-04/6000

Hioki PQ3100-04/6000 Offers

Features

  • Record data including voltage, current, power, harmonics, and flicker simultaneously along a single time axis (Flicker recording available in future firmware update)
  • Capture all power anomalies, including instantaneous outages, voltage drops, and frequency fluctuations, while simultaneously recording trend data
  • Quick Set: Easy-to-understand on-screen guide for measurement procedures
  • Bundled PQ ONE application software makes it easy to create reports
  • Record waveforms for up to 1 second before and 10 seconds after an anomaly occurs
  • Accurately measure DC currents over extended periods of time (with an AC/DC auto-zero current sensor)
  • Directly supply power to connected current sensors

Reliable Power Supply Maintenance, Management, Troubleshooting, and Analysis

The power grid is the single most important piece of infrastructure in our society, and regular maintenance and management are essential in order to prevent problems. When power supply issues are caused by factors such as equipment malfunctions or rapid surges in power demand, personnel are called upon to analyze the underlying causes quickly and precisely. The PQ3100 aids in reliable power analysis by delivering analytical capabilities that reliably captures the full range of power anomalies along with exceptional ease of use that facilitates each step of instrument operation, from connecting it to the circuit to recording data.

Recording the Power Quality of a Power Grid

The PQ3100 records data including voltage, current, power, harmonics, and flicker* simultaneously along a single time axis, and the included PQ ONE application software makes it easy to create reports.

Measure all power parameters including voltage, current, power, harmonics, and flicker simultaneously along the same time axis, giving it the ability to capture all power anomalies such as intermittent power interruptions, voltage drops and frequency fluctuations while recording the power trend.



Analyzing Device Power Supply Issues

When you need to resolve issues with a device that unexpectedly malfunctions or suddenly stops, the PQ3100 captures all power anomalies, including instantaneous outages, voltage drops, and frequency fluctuations, while simultaneously recording trend data



Measuring AC/DC Power

Used in combination with an AC/DC auto-zero current sensor, the PQ3100 can accurately measure DC currents over extended periods of time. Since the instrument supplies power to connected sensors, there's no need to use an additional power supply for sensors.



Measuring all Parameters at the Same Time

The PQ3100 makes it easy to verify current conditions by displaying all measurement parameters simple by toggling the screens.



Simultaneously Recording Trend Graphs and Event Waveforms

The PQ3100 records trend data for all parameters at once. When the PQA detects a power anomaly, the event is immediately recorded. Since maximum, minimum, and average values are recorded during each interval, you'll never miss peak values.



Manage Power Quality with Greater Convenience of the PQ ONE Bundled Application

The included PQ ONE application software for the PQ3100 Power Quality Analyzer lets you analyze captured data in fine detail and create regular power quality management reports with ease and flexibility. Investigate the cause of power anomalies in the comfort of your office using your PC.

A Simple Solution to Wiring and Configuration

Provides an intuitive QUICK SET navigation system to simplify the wiring and configuration procedures for measuring a 3-phase system. Connection mistakes such as reversing the direction of the clamp sensor or phase order are automatically detected along with suggestions on how to correct the setup.

Hioki PQ3100-04/6000 Specifications

Measurement line type Single-phase 2-wire, Single-phase 3-wire, Three-phase 3-wire or Three-phase 4-wire plus one extra input channel CH4 for voltage/current, (all channels AC/DC measurement)
Voltage ranges Voltage measurement: 1000.0 V rms or DC, Transient measurement 2.200 kV peak
Current ranges 50.000 mA AC to 5.0000 kA AC, 10.000 A DC to 2.0000 kA DC (depends on current sensor in use)
Power ranges 50.000 W to 6.0000 MW (determined automatically based on current range in use)
Basic accuracy Voltage: ±0.2% of nominal voltage, Current: ±0.1 % rdg. ±0.1 % f.s. + current sensor accuracy, Active power: DC ±0.5 % rdg. ±0.5 % f.s. + current sensor accuracy, AC ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy
Record Maximum recording interval: 1 year, Maximum number of recordable events: 9999 × 365 days
Interfaces SD/SDHC card, RS-232C (for communication/LR8410 link, available in future firmware update), LAN (HTTP server/FTP/send e-mail, available in future firmware update), USB 2.0 (for communication)
Display 6.5-inch TFT color LCD (640 × 480 dots)
Power supply AC adapter Z1002 (100 V to 240 V AC, 50/60 Hz, rated current 1.7 A), Battery pack Z1003 (Continuous use: 8 hr, Charging time: Max. 5 hr 30 m with AC adapter)
Dimensions and mass 300 mm (11.81 in)W × 211 mm (8.31 in)H × 68 mm (2.68 in)D, 2.5 kg (88.2 oz) (including battery pack)
Click here for complete specifications on the Hioki PQ3100-04/6000

What's included with the Hioki PQ3100-04/6000

  • Hioki PQ3100-01/600 Power Quality Analyzer Kit, Custom 4 Clamp, 6000A
  • AC Flexible Current Sensor CT7045 (4)
  • Carrying Case C1009
  • SD Memory Card 2GB Z4001
  • Instruction Manual
  • Measurement Guide
  • Voltage Cord L1000-05
  • Spiral Tube
  • AC Adapter Z1002
  • Strap
  • USB Cable
  • Battery Pack Z1003

Ask a question about Hioki PQ3100-04/6000 Power Quality Analyzer Kit, Custom 4 Clamp AC Flexible Current Sensor, 6000A

Customer Reviews for the Hioki PQ3100-04/6000

More Hioki Products

Calibration Lab