Hioki U8554 Strain Unit for the LR8450, 5 channels

Model: U8554

Hioki U8554 Strain Unit for the LR8450, 5 channels

Model: U8554

The strain unit is designed for the LR8450 data logger. It features strain, voltage, and strain gauge transducers with up to 5 channels as well as 1 ms sampling.

The strain unit is designed for the LR8450 data logger. It features strain, voltage, and strain gauge transducers with up to 5 channels as well as 1 ms sampling.

Your Price $2970.00 USD
Availability 2 to 3 Weeks
Quantity

Hioki U8554 Offers

Features

  • Five channels, strain measurement
  • Sampling rate of up to 1 ms with five channels
  • Direct input of strain gages and strain gage transducers

Hioki U8554 Specifications

Connectable Instruments Memory HiLogger LR8450 (Designed for use with plug-in units only)
Memory HiLogger LR8450-01 (Wireless LAN model)
Temperature and Humidity Operating: 14 to 122°F (-10 to 50°C), 80% RH or less (no condensation)
Storage: -4 to 140° (-20 to 60°C), 80% RH or less (no condensation)
Vibration resistance JIS D 1601:1995 5.3(1), Class 1A (passenger vehicle) equivalent
Input Number of channels: Five (able to set voltage or strain for each channel)
Terminals: Push-button type terminal block (five terminals per channel), outfitted with terminal block cover (set DIP switches according to measurement target)
Type: Balanced differential input, simultaneous sampling of all channels (non-isolated channels)
Resistance: 2 MΩ ±5%
Measurement Target Voltage
Strain:
Strain gage
1-gage method (2-wire setup), 1-gage method (3-wire setup), 2-gage method (adjacent sides), 4-gage method
Strain gauge transducer
Adaptive Gage Resistance 1-gage method
2-gage method: 120 Ω (external bridge box required for 350 Ω)
4-gage method: 120 Ω to 1 kΩ
Gage Ratio 2.0 (fixed)
Bridge Voltage 2 V ±0.05 V DC
Balance Adjustment Method: Electronic auto-balancing
Range voltage: ±20 mV or less (1 to 20 mV f.s. range), ±200 mV or less (50 to 200 mV f.s. range)
Strain: ±20,000 με or less (1000 to 20,000 με f.s. range), ±200,000 με or less (50,000 to 200,000 με f.s. range)
A/D Resolution 16 bit
Maximum Voltage Input: ±0.5 V DC (maximum voltage between input terminals without causing damage)
Channel-to-channel: Non-isolated (all channels share common GND)
Rated terminal-to-ground: 30 Vrms AC or 60 V DC (maximum voltage between input channel and chassis without causing damage)
Data Refresh Interval 1 ms to 10 s (13 selectable levels)
Low-Pass Filter Cut-off frequency: -3 dB ±30%
Auto, 120, 60, 30, 15, 8, 4 (Hz)
Auto: Cut-off frequency of low-pass filter is automatically set based on set data refresh interval
Attenuation characteristics: 5th-order butterworth filter, -30 dB/oct
Dimensions Approximately 5.28 × 2.76 × 2.48" (134 × 70 × 63 mm)
Mass Approximately 8.3 oz (236 g)

What's included with the Hioki U8554

  • Strain Unit
  • 2 x Mounting Screws
  • Wiring Confirmation Label
  • Instruction Manual

Ask a question about Hioki U8554 Strain Unit for the LR8450, 5 channels

Customer Reviews for the Hioki U8554

Hioki U8554 Offers

Features

  • Five channels, strain measurement
  • Sampling rate of up to 1 ms with five channels
  • Direct input of strain gages and strain gage transducers

Hioki U8554 Specifications

Connectable Instruments Memory HiLogger LR8450 (Designed for use with plug-in units only)
Memory HiLogger LR8450-01 (Wireless LAN model)
Temperature and Humidity Operating: 14 to 122°F (-10 to 50°C), 80% RH or less (no condensation)
Storage: -4 to 140° (-20 to 60°C), 80% RH or less (no condensation)
Vibration resistance JIS D 1601:1995 5.3(1), Class 1A (passenger vehicle) equivalent
Input Number of channels: Five (able to set voltage or strain for each channel)
Terminals: Push-button type terminal block (five terminals per channel), outfitted with terminal block cover (set DIP switches according to measurement target)
Type: Balanced differential input, simultaneous sampling of all channels (non-isolated channels)
Resistance: 2 MΩ ±5%
Measurement Target Voltage
Strain:
Strain gage
1-gage method (2-wire setup), 1-gage method (3-wire setup), 2-gage method (adjacent sides), 4-gage method
Strain gauge transducer
Adaptive Gage Resistance 1-gage method
2-gage method: 120 Ω (external bridge box required for 350 Ω)
4-gage method: 120 Ω to 1 kΩ
Gage Ratio 2.0 (fixed)
Bridge Voltage 2 V ±0.05 V DC
Balance Adjustment Method: Electronic auto-balancing
Range voltage: ±20 mV or less (1 to 20 mV f.s. range), ±200 mV or less (50 to 200 mV f.s. range)
Strain: ±20,000 με or less (1000 to 20,000 με f.s. range), ±200,000 με or less (50,000 to 200,000 με f.s. range)
A/D Resolution 16 bit
Maximum Voltage Input: ±0.5 V DC (maximum voltage between input terminals without causing damage)
Channel-to-channel: Non-isolated (all channels share common GND)
Rated terminal-to-ground: 30 Vrms AC or 60 V DC (maximum voltage between input channel and chassis without causing damage)
Data Refresh Interval 1 ms to 10 s (13 selectable levels)
Low-Pass Filter Cut-off frequency: -3 dB ±30%
Auto, 120, 60, 30, 15, 8, 4 (Hz)
Auto: Cut-off frequency of low-pass filter is automatically set based on set data refresh interval
Attenuation characteristics: 5th-order butterworth filter, -30 dB/oct
Dimensions Approximately 5.28 × 2.76 × 2.48" (134 × 70 × 63 mm)
Mass Approximately 8.3 oz (236 g)

What's included with the Hioki U8554

  • Strain Unit
  • 2 x Mounting Screws
  • Wiring Confirmation Label
  • Instruction Manual

Ask a question about Hioki U8554 Strain Unit for the LR8450, 5 channels