Includes 4mm stepless one-way clutch Phillips tip, 4mm Phillips tip, AC charger and carrying case Capacity: 0.20 to 69.50 ozf-in/0.020 to 4.500 lbf-in/ 0.020 to 5.000 kgf-cm/ 0.20 to 50.00 N-cm.
Includes 4mm stepless one-way clutch Phillips tip, 4mm Phillips tip, AC charger and carrying case Capacity: 0.20 to 69.50 ozf-in/0.020 to 4.500 lbf-in/ 0.020 to 5.000 kgf-cm/ 0.20 to 50.00 N-cm.
Features
Measuring Range | 2.0~500 mN・m, 0.020~5kgf・cm, 0.020~4.5lbf・in |
Accuracy | ±0.5% (499 or less digit±3digit) |
Display | The 4 figures digital display of LCD |
The measurement direction | CW-CCW (right and left) |
Data memory counts | 800 data / ten channels data |
Data output | ASCII format (baud rate 19200) |
Auto clear time | If the set-up time comes, measurement value will be automatically cleared in 0.0~3.0 seconds (0.5s interval) |
Setup of count | 1 to 99 count (count in a clockwise direction) |
Power supply | Ni-Mn chargeable battery 650mAh |
Charge time / use time | Charge about 3 hour /, continuation about 12-hour use |
Auto-power-off | After the neglect during 10 minutes |
Measurement Modes | |
Peak to Peak (PP) | The highest value of load is hold-displayed |
Track (TR) | A display also changes with load change |
Peak-Down (PD) | Load catches and displays the moment included in descent from a rise |
Real-time Output (C) | Load torque value is outputted every about1/ 160second |
Measuring Range | 2.0~500 mN・m, 0.020~5kgf・cm, 0.020~4.5lbf・in |
Accuracy | ±0.5% (499 or less digit±3digit) |
Display | The 4 figures digital display of LCD |
The measurement direction | CW-CCW (right and left) |
Data memory counts | 800 data / ten channels data |
Data output | ASCII format (baud rate 19200) |
Auto clear time | If the set-up time comes, measurement value will be automatically cleared in 0.0~3.0 seconds (0.5s interval) |
Setup of count | 1 to 99 count (count in a clockwise direction) |
Power supply | Ni-Mn chargeable battery 650mAh |
Charge time / use time | Charge about 3 hour /, continuation about 12-hour use |
Auto-power-off | After the neglect during 10 minutes |
Measurement Modes | |
Peak to Peak (PP) | The highest value of load is hold-displayed |
Track (TR) | A display also changes with load change |
Peak-Down (PD) | Load catches and displays the moment included in descent from a rise |
Real-time Output (C) | Load torque value is outputted every about1/ 160second |