Features 5mA short circuit current. Test Voltage range of 250V to 5000V. Advanced diagnosis function including Ramp Test (Breakdown and Burn modes) and tests for capacitance and leakage current.
Features 5mA short circuit current. Test Voltage range of 250V to 5000V. Advanced diagnosis function including Ramp Test (Breakdown and Burn modes) and tests for capacitance and leakage current.
Features
Voltage Measurement | |
Measuring Range | AC: 30 to 600 V (50/60 Hz) DC: ±30 to ±600 V |
Accuracy | ±2%rdg±3dgt |
Current Measurement | |
Measuring Range | 0.00 nA to 5.50 mA |
Accuracy | ±10%rdg |
Capacitance Measurement | |
Measuring Range | 5.0 nF to 50.0 µF 5.0 nF to 25.0 µF |
Accuracy | ±5%rdg±5dgt |
General | |
Applicable standards | IEC 61010-1, 61010-2-030 CAT Ⅳ 600V Pollution degree 2, IEC 61010-031, IEC 61326-1, 2-2 |
Power source | 12 V Rechargeable Battery (Lead-acid Battery) Charging power: DC 15 VA MAX |
Communication Interface | Bluetooth: Ver2.1 + EDR Class2, USB: Ver1.1 |
Dimensions | 8.19 x 8.85 x 5.12" (208 × 225 × 130 mm) |
Voltage Measurement | |
Measuring Range | AC: 30 to 600 V (50/60 Hz) DC: ±30 to ±600 V |
Accuracy | ±2%rdg±3dgt |
Current Measurement | |
Measuring Range | 0.00 nA to 5.50 mA |
Accuracy | ±10%rdg |
Capacitance Measurement | |
Measuring Range | 5.0 nF to 50.0 µF 5.0 nF to 25.0 µF |
Accuracy | ±5%rdg±5dgt |
General | |
Applicable standards | IEC 61010-1, 61010-2-030 CAT Ⅳ 600V Pollution degree 2, IEC 61010-031, IEC 61326-1, 2-2 |
Power source | 12 V Rechargeable Battery (Lead-acid Battery) Charging power: DC 15 VA MAX |
Communication Interface | Bluetooth: Ver2.1 + EDR Class2, USB: Ver1.1 |
Dimensions | 8.19 x 8.85 x 5.12" (208 × 225 × 130 mm) |