Offers high accuracy and stability, this benchtop load cell and microvolt meter is ideal for low-level signal measurements. Allows four or 6-wire connection to avoid lead resistance effects with input range from 20 to 500 mV. In addition, it is powered by 85 to 264 V AC / 90 to 300 V DC.
Offers high accuracy and stability, this benchtop load cell and microvolt meter is ideal for low-level signal measurements. Allows four or 6-wire connection to avoid lead resistance effects with input range from 20 to 500 mV. In addition, it is powered by 85 to 264 V AC / 90 to 300 V DC.
Ideal for industrial use, the Laureate digital panel meters are housed in a ⅛ DIN case that is compact and rugged with NEMA 4X protection at the front of the case. Allows easy setup with fully configured and calibrated units.
Features
Applications
Display Color | Basic DPM with green LEDs |
Power | 85 to 264 V AC / 90 to 300 V DC |
Analog Output | Isolated 4 to 20 mA, 0 to 20 mA, 0 to 10 V, -10 to 10 V |
Signal Input | Load cells (Four or 6-wire, ratiometric). Custom scaling. |
DC Microvoltmeter Inputs | Input Range mV: ±20/±50/±100/±250/±500 Input resistance: 1 Gohm Error at 25°C: ±0.01% of full scale ±2 counts |
Load Cell Inputs | Full-scale input: ±20/±50/±100/±250/±500 mV Zero adjust: -99,999 to 99,999 Span adjust: 0 to ±99,999 Input resistance: 1 Gohm Error at 25°C: ±0.01% of full scale ±2 counts |
Noise Rejection | CMR, DC to 60 Hz: 130 dB NMR at 50/60 Hz: 90 dB with min filtering |
Display | Readout: 5 LED digits, 7-segment, .56" (14.2 mm), green Range: -99999 to 99999 or -99990 to 99990 (count by 10) Indicators: Minus sign, 2 red LED lamps |
Dimension | 3.78 x 1.89 x 4.02" (96 x 48 x 102 mm) |
Weight | 0.46 lb (210 g) |
Display Color | Basic DPM with green LEDs |
Power | 85 to 264 V AC / 90 to 300 V DC |
Analog Output | Isolated 4 to 20 mA, 0 to 20 mA, 0 to 10 V, -10 to 10 V |
Signal Input | Load cells (Four or 6-wire, ratiometric). Custom scaling. |
DC Microvoltmeter Inputs | Input Range mV: ±20/±50/±100/±250/±500 Input resistance: 1 Gohm Error at 25°C: ±0.01% of full scale ±2 counts |
Load Cell Inputs | Full-scale input: ±20/±50/±100/±250/±500 mV Zero adjust: -99,999 to 99,999 Span adjust: 0 to ±99,999 Input resistance: 1 Gohm Error at 25°C: ±0.01% of full scale ±2 counts |
Noise Rejection | CMR, DC to 60 Hz: 130 dB NMR at 50/60 Hz: 90 dB with min filtering |
Display | Readout: 5 LED digits, 7-segment, .56" (14.2 mm), green Range: -99999 to 99999 or -99990 to 99990 (count by 10) Indicators: Minus sign, 2 red LED lamps |
Dimension | 3.78 x 1.89 x 4.02" (96 x 48 x 102 mm) |
Weight | 0.46 lb (210 g) |