Versatile for a broad range of commercial/industrial submetering applications, this advanced 3-phase meter with LCD helps lower the total cost of collecting data by reducing install complexity and increasing flexibility. In addition, this meter features a DIN rail mount and monitors a single 3-phase circuit.
Versatile for a broad range of commercial/industrial submetering applications, this advanced 3-phase meter with LCD helps lower the total cost of collecting data by reducing install complexity and increasing flexibility. In addition, this meter features a DIN rail mount and monitors a single 3-phase circuit.
Monitor the voltage, current, power, energy, and many other electrical parameters with this 3-phase meter. Help lower the total cost of collecting data by reducing install complexity and increasing flexibility with this meter. In addition, this meter's plug-and-play integration ensures that the full complement of data points is captured immediately and made available for countless applications.
Support all industry-standard communications protocols with this meter, which includes RS-485, BACnet MS/TP, BACnet IP, Modbus TCP, and Ethernet for maximum flexibility. Moreover, as a circuit approaches the user-configured threshold, alarm indicators are triggered to prevent costly downtime from overloaded circuits or failed loads.
Features
Capabilities (measured parameters: all parameters for each phase and system total)
Applications
Track all reneweable energy data ensuring accuracy in billing and crediting
This advanced 3-phase meter feature bidirectional monitoring specifically designed for renewable energy applications. This meter measures power imported from the utility grid and power exported from renewable energy sources such as solar panels. In addition, this allows facility managers to track all energy data, ensuring accuracy in billing and crediting.
Challenge: Facility has incorporated renewable energy technologies, including wind and solar, into their building's design
Solution: This meter is designed to accurately track imported and exported power for renewable energy applications
What you will need
Complete metering solutions by VerifEye: Cost-effective and flexible industrial metering solutions
Growing demand for building owners to meet energy codes, lower demand charges, allocate costs and bill tenants has increased the need for a flexible, cost-effective submetering solution. Combined with the challenge of installing equipment in existing buildings, building owners and facility managers need flexible solutions that work in a variety of locations and applications.
This meter satifies theses requirements with a versatile platform featuring revenue grade accuracy, universal voltage and CE compliance, DIN rail mount, and industrial temperature range.
Challenge: A contractor needs to install a submeter for use in a variety of global applications and environments while staying within a budget
Solution: A cost-effective, easy-to-use submetering solution for multiple locations and a variety of applications
What you will need
Service Type | 1P/2W, 2P/3W, 3P/4W, 3P/3W (Delta) Single phase, split phase, three phase-four wire (WYE) |
Power | From L1 phase to L2 phase, 90 to 600 V AC RMS CAT III 50/60 Hz, 500 mA AC maximum Out: Unregulated 12 V DC output, 200 mA, self-resetting fuse Use of 12 V auxiliary output requires 100 V AC minimum input voltage |
AC Protection | 0.5 A fuse 200 kA interrupt capacity |
Channels | Voltage: 90 to 346 V AC line-to-neutral, 600 V line-to-line, CAT III Current: 3 channels, 0.525 V AC maximum, 333 mV CTs, 0 to 4000 A depending on CT |
Maximum Current Input | 150% of current transducer rating (mV CTs) to maintain accuracy. Measure up to 4000 A with Rogowski coil CTs |
Measurements | Volts, amps, kW, kVAR, kVA, aPF, dPF, kW demand, kVA demand, import (received) kWh, export (delivered) kWh, net kWh, import (received) kVAh, export (delivered) kVAh, net kVAh, import (received) kVARh, export (delivered) kVARh, net kVARh, THD, theta, frequency. All parameters for each phase and system total. Type: True RMS using high-speed Digital Signal Processing (DSP) with continuous sampling |
Accuracy | 0.2% ANSI C12.20-2010 Class 0.2 |
Line Frequency | 50/60Hz |
Waveform Sampling | 1.8 kHz |
Parameter Update Rate | 1 second |
Resolution | Values reported in IEEE-754 single precision floating point format (32 bit) |
Indicators | 4-line display, tri-clor backlight (PhaseCheck™) |
Alarm Output | Over/under voltage and current (SPDT relay - 30 V DC) |
Wire Connections | 12 to 22 AWG 600 V AC, voltage connection must be #14 AWG or larger and 600 V AC rated |
Mounting | DIN rail mount PCBA: 0.5" standoffs #6 (quantity 6, user supplied) |
High Voltage Cover | IP30 (embedded version) |
Hardware | RS-485, Ethernet and USB (for configuration only) |
Supported Protocols | ModBus, BACnet MS/TP, ModBus TCP or BACnet IP |
Communication Rate (Baud) | ModBus: 9600 (default), 19200, 38400, 57600, 76800, 115200 BACnet: 9600 (default), 19200, 38400, 76800 |
Maximum Distance | ModBus RTU - 4000' (1200 m) maximum, other network protocols follow standard network management practices |
RS-485 Loading | ⅛ unit |
Data Bits | 8 |
Parity | None, even, odd |
Stop Bit | 2, 1 |
Environmental | Operating temperature: -4 to 140°F (-20 to 60°C) at -4°F (-20°C), LCD display could be illegible, meter voltage at -4°F (-20°C) must exceed 100 V AC to power the meter Operating humidity: 5 to 95% non-condensing |
Codes and Standards | Accuracy and billing: ANSI C12.20 Class 0.2, NIST traceable calibration Listing/safety: CE EN 61000-6-4: Class A, UL listed |
Enclosure | ABS plastic, 94-V0 flammability rating, connections sized for 1" EMT conduit |
Dimensions | DIN rail mount: 3.24 x 7.5 x 1.79" (82.2 x 190.3 x 45.5 mm) |
Service Type | 1P/2W, 2P/3W, 3P/4W, 3P/3W (Delta) Single phase, split phase, three phase-four wire (WYE) |
Power | From L1 phase to L2 phase, 90 to 600 V AC RMS CAT III 50/60 Hz, 500 mA AC maximum Out: Unregulated 12 V DC output, 200 mA, self-resetting fuse Use of 12 V auxiliary output requires 100 V AC minimum input voltage |
AC Protection | 0.5 A fuse 200 kA interrupt capacity |
Channels | Voltage: 90 to 346 V AC line-to-neutral, 600 V line-to-line, CAT III Current: 3 channels, 0.525 V AC maximum, 333 mV CTs, 0 to 4000 A depending on CT |
Maximum Current Input | 150% of current transducer rating (mV CTs) to maintain accuracy. Measure up to 4000 A with Rogowski coil CTs |
Measurements | Volts, amps, kW, kVAR, kVA, aPF, dPF, kW demand, kVA demand, import (received) kWh, export (delivered) kWh, net kWh, import (received) kVAh, export (delivered) kVAh, net kVAh, import (received) kVARh, export (delivered) kVARh, net kVARh, THD, theta, frequency. All parameters for each phase and system total. Type: True RMS using high-speed Digital Signal Processing (DSP) with continuous sampling |
Accuracy | 0.2% ANSI C12.20-2010 Class 0.2 |
Line Frequency | 50/60Hz |
Waveform Sampling | 1.8 kHz |
Parameter Update Rate | 1 second |
Resolution | Values reported in IEEE-754 single precision floating point format (32 bit) |
Indicators | 4-line display, tri-clor backlight (PhaseCheck™) |
Alarm Output | Over/under voltage and current (SPDT relay - 30 V DC) |
Wire Connections | 12 to 22 AWG 600 V AC, voltage connection must be #14 AWG or larger and 600 V AC rated |
Mounting | DIN rail mount PCBA: 0.5" standoffs #6 (quantity 6, user supplied) |
High Voltage Cover | IP30 (embedded version) |
Hardware | RS-485, Ethernet and USB (for configuration only) |
Supported Protocols | ModBus, BACnet MS/TP, ModBus TCP or BACnet IP |
Communication Rate (Baud) | ModBus: 9600 (default), 19200, 38400, 57600, 76800, 115200 BACnet: 9600 (default), 19200, 38400, 76800 |
Maximum Distance | ModBus RTU - 4000' (1200 m) maximum, other network protocols follow standard network management practices |
RS-485 Loading | ⅛ unit |
Data Bits | 8 |
Parity | None, even, odd |
Stop Bit | 2, 1 |
Environmental | Operating temperature: -4 to 140°F (-20 to 60°C) at -4°F (-20°C), LCD display could be illegible, meter voltage at -4°F (-20°C) must exceed 100 V AC to power the meter Operating humidity: 5 to 95% non-condensing |
Codes and Standards | Accuracy and billing: ANSI C12.20 Class 0.2, NIST traceable calibration Listing/safety: CE EN 61000-6-4: Class A, UL listed |
Enclosure | ABS plastic, 94-V0 flammability rating, connections sized for 1" EMT conduit |
Dimensions | DIN rail mount: 3.24 x 7.5 x 1.79" (82.2 x 190.3 x 45.5 mm) |