Leviton 1O240-01W Outdoor 120/240V Single Phase kWh Meter Kit, 100A, 2 Split Core CTs

Model: 1O240-01W | Order No: 1O240-1W | UPC: 078477597460

Leviton 1O240-01W Outdoor 120/240V Single Phase kWh Meter Kit, 100A, 2 Split Core CTs

Model: 1O240-01W | Order No: 1O240-1W | UPC: 078477597460

Series 1000 Outdoor Enclosure Kit includes submeter and required current transformers (CTs). Features 120/208V, 1PH/3W or 120/240V, 1PH/3W (Split Phase) with NEMA 4X Enclosure and is ASHRAE 90.1 Compliant. Outdoor 120/240V Single Phase kWh Meter Kit, 100A, 2 Split Core CTs.

Series 1000 Outdoor Enclosure Kit includes submeter and required current transformers (CTs). Features 120/208V, 1PH/3W or 120/240V, 1PH/3W (Split Phase) with NEMA 4X Enclosure and is ASHRAE 90.1 Compliant. Outdoor 120/240V Single Phase kWh Meter Kit, 100A, 2 Split Core CTs.

Sale Price $465.52 USD
Regular Price $506.00 USD
Availability 2 in Stock
Quantity

Leviton 1000 Series Offers

The Leviton VerifEye Series 1000 line of revenue-grade meters meets all measurement and verification-based opportunities — including load management and LEED rating achievement. Designed to provide a simple and effective process for accurately capturing measurements of power consumption, Series 1000 Meters are easy to specify and install for new construction and retrofits.

Leviton meters utilize highly accurate current transformers (CTs) for revenue-grade performance certified to ANSI standards. Competing products use current sensors that do not provide the same level of performance. Leviton offers CTs in solid and split core styles to accommodate all phases of installation and construction.

Solid core CTs are ideal for new construction, when power is not live and wires can easily be threaded through the core. Split core CTs can be installed at any time without having to disconnect wire terminations, making them the optimal choice for retrofitting an existing structure. Split core CTs close securely for fast, precise installation with no need for time-consuming tie wraps and no worries about improper seating or core half separation. Both solid and split core CTs offer high quality, long term accuracy and reliability. Leviton solid core CTs are cost effective and less susceptible to damage during installation. Solid core CTs slip over power lines to measure the electrical current flowing through the line. The CT "secondary" wires connect to the meter facilitating power and energy calculations. They are compact and cost effective. Solid core CTs are accurate (0.3% maximum error). For installation, power must be de-energized and the circuit opened in order to slip the CT over the power line.

Split core CTs close securely for fast, precise installation with no need for time-consuming tie wraps and no worries about improper seating or core half separation. Both solid and split core CTs offer high quality, long term accuracy and reliability. Split core CTs can be disassembled or 'split' into halves eliminating the need to turn power off and open the circuit during installation. This time-saving installation is ideal for critical loads that cannot be disconnected. Split core CTs close securely for fast, precise installation with no need for time-consuming tie wraps and no worries about improper seating or core half separation.

Every Series 1000 Meter has an installer friendly feedback feature. The red reverse phase indicator acts as an installation diagnostics tool and illuminates if a meter is improperly installed. After installation, the green duty cycle light shows that the meter is collecting the electrical consumption data at the appropriate rate. All 100 and 200 Amp solid core CTs have color-coded labels to easily identify and correctly land the wires at the meter.

Features

  • Measures kWh and demand (optional)
  • Conforms to all applicable standards of ANSI C12.1
  • Reverse energy LED indicator helps ensure proper installation
  • Equipped with an Isolated Pulse Output channel
  • Utilizes revenue-grade 0.3% accuracy class 0.1A secondary solid core CTs that conform to all applicable ANSI requirements or 1.0% accuracy split-core CTs (CT's sold separately)
  • Enclosures include surface mount industrial grade JIC steel indoor and NEMA 4X outdoor
  • Interfaces with numerous communication systems – Hardwired Automatic Meter Reading (AMR) or wireless AMR
  • Large LCD display shows kWh and instantaneous and peak demand (optionally) with manual keyed reset
  • Load Indicator LED verifies meter functionality
  • Reverse Phase Indicator LED illuminates if the meter is improperly installed
  • UL/cUL Listed for UL 916 Energy Monitoring Equipment
  • Ten year warranty

Applications

  • Load Profiling and benchmarking
  • Usage aggregation
  • Tenant cost allocation
  • Measurement and verification
  • Energy conservation and cost reduction
  • Green building initiatives and government mandates

Leviton 1O240-01W Specifications

Voltage 120/208V 1 PH 3 W or 120/240V 1 PH 3 W (Split Phase)
Amps 100
CTs Included 2 Split CTs
Click here for complete specifications on the Leviton 1O240-01W

What's included with the Leviton 1O240-01W

  • Leviton 1O240-01W Outdoor 120/240V Single Phase kWh Meter Kit, 100A, 2 Split Core CTs

Ask a question about Leviton 1O240-01W Outdoor 120/240V Single Phase kWh Meter Kit, 100A, 2 Split Core CTs

Customer Reviews for the Leviton 1O240-01W

Leviton 1000 Series Offers

The Leviton VerifEye Series 1000 line of revenue-grade meters meets all measurement and verification-based opportunities — including load management and LEED rating achievement. Designed to provide a simple and effective process for accurately capturing measurements of power consumption, Series 1000 Meters are easy to specify and install for new construction and retrofits.

Leviton meters utilize highly accurate current transformers (CTs) for revenue-grade performance certified to ANSI standards. Competing products use current sensors that do not provide the same level of performance. Leviton offers CTs in solid and split core styles to accommodate all phases of installation and construction.

Solid core CTs are ideal for new construction, when power is not live and wires can easily be threaded through the core. Split core CTs can be installed at any time without having to disconnect wire terminations, making them the optimal choice for retrofitting an existing structure. Split core CTs close securely for fast, precise installation with no need for time-consuming tie wraps and no worries about improper seating or core half separation. Both solid and split core CTs offer high quality, long term accuracy and reliability. Leviton solid core CTs are cost effective and less susceptible to damage during installation. Solid core CTs slip over power lines to measure the electrical current flowing through the line. The CT "secondary" wires connect to the meter facilitating power and energy calculations. They are compact and cost effective. Solid core CTs are accurate (0.3% maximum error). For installation, power must be de-energized and the circuit opened in order to slip the CT over the power line.

Split core CTs close securely for fast, precise installation with no need for time-consuming tie wraps and no worries about improper seating or core half separation. Both solid and split core CTs offer high quality, long term accuracy and reliability. Split core CTs can be disassembled or 'split' into halves eliminating the need to turn power off and open the circuit during installation. This time-saving installation is ideal for critical loads that cannot be disconnected. Split core CTs close securely for fast, precise installation with no need for time-consuming tie wraps and no worries about improper seating or core half separation.

Every Series 1000 Meter has an installer friendly feedback feature. The red reverse phase indicator acts as an installation diagnostics tool and illuminates if a meter is improperly installed. After installation, the green duty cycle light shows that the meter is collecting the electrical consumption data at the appropriate rate. All 100 and 200 Amp solid core CTs have color-coded labels to easily identify and correctly land the wires at the meter.

Features

  • Measures kWh and demand (optional)
  • Conforms to all applicable standards of ANSI C12.1
  • Reverse energy LED indicator helps ensure proper installation
  • Equipped with an Isolated Pulse Output channel
  • Utilizes revenue-grade 0.3% accuracy class 0.1A secondary solid core CTs that conform to all applicable ANSI requirements or 1.0% accuracy split-core CTs (CT's sold separately)
  • Enclosures include surface mount industrial grade JIC steel indoor and NEMA 4X outdoor
  • Interfaces with numerous communication systems – Hardwired Automatic Meter Reading (AMR) or wireless AMR
  • Large LCD display shows kWh and instantaneous and peak demand (optionally) with manual keyed reset
  • Load Indicator LED verifies meter functionality
  • Reverse Phase Indicator LED illuminates if the meter is improperly installed
  • UL/cUL Listed for UL 916 Energy Monitoring Equipment
  • Ten year warranty

Applications

  • Load Profiling and benchmarking
  • Usage aggregation
  • Tenant cost allocation
  • Measurement and verification
  • Energy conservation and cost reduction
  • Green building initiatives and government mandates

Leviton 1O240-01W Specifications

Voltage 120/208V 1 PH 3 W or 120/240V 1 PH 3 W (Split Phase)
Amps 100
CTs Included 2 Split CTs
Click here for complete specifications on the Leviton 1O240-01W

What's included with the Leviton 1O240-01W

  • Leviton 1O240-01W Outdoor 120/240V Single Phase kWh Meter Kit, 100A, 2 Split Core CTs

Ask a question about Leviton 1O240-01W Outdoor 120/240V Single Phase kWh Meter Kit, 100A, 2 Split Core CTs

Customer Reviews for the Leviton 1O240-01W

More Leviton Products

Calibration Lab