Automatically upload real-time temperature data to your online cloud account with this data logger, which includes a non-volatile 32,000-reading memory and a large, easy-to-read display. In addition, this data logger is compatible with numerous external temperature probes (sold separately) for all your temperature needs.
Automatically upload real-time temperature data to your online cloud account with this data logger, which includes a non-volatile 32,000-reading memory and a large, easy-to-read display. In addition, this data logger is compatible with numerous external temperature probes (sold separately) for all your temperature needs.
Features
Applications
Sensor Measurement Range | -40 to 210°F (-40 to 99°C) |
Rated Temperature Reading Resolution | Better than 0.2°F (0.1°C) for -22 to 140°F (-30 to 60°C) Better than0.4°F (0.2°C) for -40 to -22°F (-40 to -30°C) Better than 0.9°F (0.5°C) for 140 to 158°F (60 to 70°C), typically ±0.6°F (0.3°C) |
Rated Temperature Reading Accuracy | Better than ±0.9°F (±0.5°C) for -4 to 104°F (-20 to 40°C), typically ±0.6°F (0.3°C) Better than ±1.4°F (±0.8°C) for -40 to -4°F (-40 to -20°C), typically ±0.9°F (0.5°C) Better than ±1.4°F (±0.8°C) for 104 to 158°F (40 to 70°C), typically ±1.3°F (0.7°C) Better than ±2.2°F (±1.2°C) for 158 to 210°F (70 to 99°C), typically ±1.8°F (1°C) |
Probe Connectivity | Up to 2 |
Probe Compatibility | All ST100 precision thermistor external probes can be interchangeably connected to the UTRED30-WiFi. Please refer to the page for External Probes on the LogTag North America website |
Recording Capacity | 32,000 total log memory. Provides 16,000 temperature readings per channel. Day summary statistics memory (for display on LCD): up to 30 days of Min/Max/duration and alarm trigger statistics |
Sampling Interval | Configurable from 30 seconds to 18 hours |
Logging Start Options | Push button start (with configurable start delay from 1 minute to 72 hours) or specific date & time |
Download Time | Typically with full memory (32,130 readings) in less than 10 seconds |
Environmental Conditions | Operating temperature: -22 to 140&E4deg;F (-30 to 60°C) Storage temperature: 32 to 104 °F (-10 to 40 °C) |
Protection Rating | IP51 (when vertically mounted or hung with USB dust-cap in place) |
Calibration | Factory calibrated using NIST equivalent reference equipment. Calibration certificate available on request |
Power Source | 5V via micro USB socket or, 2 x 1.5V AAA batteries. CR2032 LiMnO₂ coin cell (backup logging function only) |
Battery Life | Device should normally be powered via USB. AAA batteries provide backup power for up to 2 months |
Connection Interface | USB 2.0/Micro-USB plug |
Wifi | 802.11 b/g/n |
Bluetooth™ | Bluetooth® V4.2 BR/EDR and Bluetooth LE® |
Case Material | Polycarbonate |
Dimensions | 5.5 x 2.8 x 0.7" (141 x 72 x 18 mm) |
Weight | 0.3 lbs (158 g) with AAA batteries, (0.295 lbs (134 g) - excluding probe and AAA batteries) |
Click on a category to view a selection of compatible accessories with the LogTag UTRED30-WIFI Dual-Channel LCD Data Logger.
Sensor Measurement Range | -40 to 210°F (-40 to 99°C) |
Rated Temperature Reading Resolution | Better than 0.2°F (0.1°C) for -22 to 140°F (-30 to 60°C) Better than0.4°F (0.2°C) for -40 to -22°F (-40 to -30°C) Better than 0.9°F (0.5°C) for 140 to 158°F (60 to 70°C), typically ±0.6°F (0.3°C) |
Rated Temperature Reading Accuracy | Better than ±0.9°F (±0.5°C) for -4 to 104°F (-20 to 40°C), typically ±0.6°F (0.3°C) Better than ±1.4°F (±0.8°C) for -40 to -4°F (-40 to -20°C), typically ±0.9°F (0.5°C) Better than ±1.4°F (±0.8°C) for 104 to 158°F (40 to 70°C), typically ±1.3°F (0.7°C) Better than ±2.2°F (±1.2°C) for 158 to 210°F (70 to 99°C), typically ±1.8°F (1°C) |
Probe Connectivity | Up to 2 |
Probe Compatibility | All ST100 precision thermistor external probes can be interchangeably connected to the UTRED30-WiFi. Please refer to the page for External Probes on the LogTag North America website |
Recording Capacity | 32,000 total log memory. Provides 16,000 temperature readings per channel. Day summary statistics memory (for display on LCD): up to 30 days of Min/Max/duration and alarm trigger statistics |
Sampling Interval | Configurable from 30 seconds to 18 hours |
Logging Start Options | Push button start (with configurable start delay from 1 minute to 72 hours) or specific date & time |
Download Time | Typically with full memory (32,130 readings) in less than 10 seconds |
Environmental Conditions | Operating temperature: -22 to 140&E4deg;F (-30 to 60°C) Storage temperature: 32 to 104 °F (-10 to 40 °C) |
Protection Rating | IP51 (when vertically mounted or hung with USB dust-cap in place) |
Calibration | Factory calibrated using NIST equivalent reference equipment. Calibration certificate available on request |
Power Source | 5V via micro USB socket or, 2 x 1.5V AAA batteries. CR2032 LiMnO₂ coin cell (backup logging function only) |
Battery Life | Device should normally be powered via USB. AAA batteries provide backup power for up to 2 months |
Connection Interface | USB 2.0/Micro-USB plug |
Wifi | 802.11 b/g/n |
Bluetooth™ | Bluetooth® V4.2 BR/EDR and Bluetooth LE® |
Case Material | Polycarbonate |
Dimensions | 5.5 x 2.8 x 0.7" (141 x 72 x 18 mm) |
Weight | 0.3 lbs (158 g) with AAA batteries, (0.295 lbs (134 g) - excluding probe and AAA batteries) |
Click on a category to view a selection of compatible accessories with the LogTag UTRED30-WIFI Dual-Channel LCD Data Logger.