Ideal for remote temperature measurements, this Bluetooth RTD temperature data logger empowers you to measure temperatures across a range from -148 to 392°F (-100 to 200°C) with unparalleled accuracy. In addition, this data logger captures critical temperature data with unmatched reliability and includes a 48" RTD probe.
Ideal for remote temperature measurements, this Bluetooth RTD temperature data logger empowers you to measure temperatures across a range from -148 to 392°F (-100 to 200°C) with unparalleled accuracy. In addition, this data logger captures critical temperature data with unmatched reliability and includes a 48" RTD probe.
Work with a massive storage capacity of over 100,000 readings with this Bluetooth datalogger, allowing you to confidently collect data for extended periods without needing to download constantly. Streamline your data logging process with this datalogger that keeps you informed at a glance with its large LCD to deliver real-time readings. In addition, this data logger is compatible with the Madgetech app, allowing you to collect data via Bluetooth connectivity effortlessly.
Features
Applications
Features
Current status
Add devices page
Devices that have Bluetooth enabled that have not previously been claimed by the current phone will appear here. If you do not see your device, move the phone closer to it. Click on a device to add it to your Home/Devices page.
Reports page
Displays all previously created reports. Reports can be sorted based on date or utilize filtering as outlined below:
Main menu
Clicking the main menu in the top left corner will launch the main menu.
Quick access buttons
Quick connect button: Enable or disable quick connect. When quick connect is on and Bluetooth is enabled, the device will automatically connect and download readings when within range. If automatic report generation and automatic report sharing are also enabled, quick connect will automatically connect, download data, generate a report and share the report to the default contact.
General settings
Quick connect: When quick connect is on and Bluetooth is enabled, the device will automatically connect and download readings when within range. If automatic report generation and automatic report sharing are also enabled, quick connect will automatically connect, download data, generate a report and share the report to the default contact. Quick connect can also be toggled on or off using the 'Q' button located in the top navigation
Report settings
Automatic generation: Select whether a report is automatically created when a device is connected, either through quick connect or manual connection. Enabling this will automatically clear the device's readings and restart the device once the report has been generated.
Notifications settings
Device main page
Device control buttons
Device general settings
Alarm settings
Trigger settings
Trigger settings can be configured to allow a device to automatically begin and stop recording data when certain reading thresholds are reached. Triggers can be set in two modes:
Window: Recording will begin when a reading is below the low setpoint, or above the high setpoint. Select fill memory on first trigger to continuously record until device memory is full. Alternately, specify the desired number of readings in the trigger sample count field. Recording will stop after that number of readings until the setpoint is reached again.
Two-point: Set both high and low start/stop setpoints. To begin recording, a reading must be above the high setpoint or below the low setpoint. To stop recording, a reading must be below the high setpoint or above the low setpoint.
Start/stop settings
When starting a device to record data, several options and start methods are available. Start settings can be specified before deploying the device.
Start method:
Stop method:
Reading interval
Specifies how often a reading should be taken and can be set from one reading every one second to one reading every 24-hours. Once you have configured settings, choose to either start your device, or save the settings to be applied to additional devices.
Measurement Range | -148 to 392°F (-100 to 200°C) |
Temperature Resolution | 0.18°F (0.1°C) |
Calibrated Accuracy | ± 0.9°F (±0.5°C) from -148 to 176°F (-100 to 80°C) ±1.8°F (±1°C) from 176 to 392°F (80 to 200°C) |
Modes | Start: Immediate start Delay start up to 18 months Pushbutton Stop: Pushbutton Timed (specific date and time) Multiple start/stop: Start and stop the device multiple times without having to download data or communicate with a PC |
Real Time Recording | May be used with MadgeTech App to monitor and record data in real time |
Memory | 131,071 total readings 21,845 readings in multiple Start/stop mode |
Reading Rate | 1 reading every second, up to 1 reading every 12 hours |
Alarm | Programmable high and low limits; alarm is activated when measurement reaches or exceeds set limits |
LCD | 1.7 x.975" (40 x 22 mm) |
Calibration | Digital calibration through software Date: Automatically recorded within device |
Data Format | Date and time stamped °C, °F, or %RH |
Time Accuracy | ±4.1 minute/month at 77°F (25°C) |
Computer Interface | USB (interface cable required) |
Software Compatibility | MT Link | MT4 |
Operating Environment | -4 to 140°F (-20 to 60°C) 0 to 95% RH non-condensing |
Battery | Type: User replacable CR2450 coin cell battery Life: 6-months typical at a 15 minute reading rate |
Materials | Polycarbonate |
Approvals | US (FCC), CA (IC), CE, South Korea (KCC), China (CMIIT), Taiwan (NCC), Japan (LCIE) |
Dimensions | 3.75 x 2.12 x 0.7" (95 x 55 x 17 mm) |
Weight | 1.8 oz (51 g) |
Click on a category to view a selection of compatible accessories with the MadgeTech LynxPro-RTD Bluetooth RTD Temperature Data Logger with LCD and RTD probe, -148 to 392°F, 0.18°F.
Measurement Range | -148 to 392°F (-100 to 200°C) |
Temperature Resolution | 0.18°F (0.1°C) |
Calibrated Accuracy | ± 0.9°F (±0.5°C) from -148 to 176°F (-100 to 80°C) ±1.8°F (±1°C) from 176 to 392°F (80 to 200°C) |
Modes | Start: Immediate start Delay start up to 18 months Pushbutton Stop: Pushbutton Timed (specific date and time) Multiple start/stop: Start and stop the device multiple times without having to download data or communicate with a PC |
Real Time Recording | May be used with MadgeTech App to monitor and record data in real time |
Memory | 131,071 total readings 21,845 readings in multiple Start/stop mode |
Reading Rate | 1 reading every second, up to 1 reading every 12 hours |
Alarm | Programmable high and low limits; alarm is activated when measurement reaches or exceeds set limits |
LCD | 1.7 x.975" (40 x 22 mm) |
Calibration | Digital calibration through software Date: Automatically recorded within device |
Data Format | Date and time stamped °C, °F, or %RH |
Time Accuracy | ±4.1 minute/month at 77°F (25°C) |
Computer Interface | USB (interface cable required) |
Software Compatibility | MT Link | MT4 |
Operating Environment | -4 to 140°F (-20 to 60°C) 0 to 95% RH non-condensing |
Battery | Type: User replacable CR2450 coin cell battery Life: 6-months typical at a 15 minute reading rate |
Materials | Polycarbonate |
Approvals | US (FCC), CA (IC), CE, South Korea (KCC), China (CMIIT), Taiwan (NCC), Japan (LCIE) |
Dimensions | 3.75 x 2.12 x 0.7" (95 x 55 x 17 mm) |
Weight | 1.8 oz (51 g) |
Click on a category to view a selection of compatible accessories with the MadgeTech LynxPro-RTD Bluetooth RTD Temperature Data Logger with LCD and RTD probe, -148 to 392°F, 0.18°F.