Accurately monitors and records at user-programmable reading intervals and can also monitor and record transient pressure through software configuration of user-defined trigger thresholds and periods with 0 to 30 psig and keyring end cap.
Accurately monitors and records at user-programmable reading intervals and can also monitor and record transient pressure through software configuration of user-defined trigger thresholds and periods with 0 to 30 psig and keyring end cap.
The intrinsically safe pressure and temperature datalogger has a programmable start time.
Features
Applications
Specifications | |
Temperature Sensor | Semiconductor |
Probe Measurement Range | -40 to +176°F (-40 to +80°C) |
Temperature Resolution | 1.8°F (1°C) |
Calibrated Accuracy | 3.6°F (±2°C) at +32 to +122°F (0 to +50°C) 7.2°F (±4°C) at -40 to +30°F (-40 to -1°C) 7.2°F(±4°C) at +124 to +185°F (+51 to +85°C) |
Pressure Sensor | Semiconductor strain gauge |
Pressure Response Time | 0.1 ms (10 to 90 %FSR) |
Repeatability | ±0.5 %FSR; ±0.2 % typical |
Calibration | Digital calibration through software |
Calibration Date | Automatically recorded within device |
Battery Type | 3.6 V lithium battery included; user replaceable |
Battery Life | 1 year typical (1 minute reading rate at 25°C) 10 days at 128 Hz in transient mode |
Data Format | Date and time stamped °C, °F, K, °R ; mbar, PSI, inHg, mmHg, atm, Torr, Pa, kPa, MPa, m |
Time Accuracy | ±1 minute/month at 25°C |
Computer Interface | IFC400 or IFC406 USB docking station required |
Operating System Compatibility | Windows XP SP3 or later |
Operating Environment | -40 to +176°F (-40 to +80°C) 0% RH to 100% RH |
Dimensions (Body) | 3.6 x 0.97" dia. (91.3 x 24.6 mm dia.) |
Weight | 5.5 oz (156 g) |
Material | 316 Stainless Steel/Radel |
Approvals | CE FM Class 3600, latest revision FM Class 3610, latest revision CAN/CSA-C22.2 No. 60079-0:15 CAN/CSA-C22.2 No. 60079-11:14 |
Specifications | |
Temperature Sensor | Semiconductor |
Probe Measurement Range | -40 to +176°F (-40 to +80°C) |
Temperature Resolution | 1.8°F (1°C) |
Calibrated Accuracy | 3.6°F (±2°C) at +32 to +122°F (0 to +50°C) 7.2°F (±4°C) at -40 to +30°F (-40 to -1°C) 7.2°F(±4°C) at +124 to +185°F (+51 to +85°C) |
Pressure Sensor | Semiconductor strain gauge |
Pressure Response Time | 0.1 ms (10 to 90 %FSR) |
Repeatability | ±0.5 %FSR; ±0.2 % typical |
Calibration | Digital calibration through software |
Calibration Date | Automatically recorded within device |
Battery Type | 3.6 V lithium battery included; user replaceable |
Battery Life | 1 year typical (1 minute reading rate at 25°C) 10 days at 128 Hz in transient mode |
Data Format | Date and time stamped °C, °F, K, °R ; mbar, PSI, inHg, mmHg, atm, Torr, Pa, kPa, MPa, m |
Time Accuracy | ±1 minute/month at 25°C |
Computer Interface | IFC400 or IFC406 USB docking station required |
Operating System Compatibility | Windows XP SP3 or later |
Operating Environment | -40 to +176°F (-40 to +80°C) 0% RH to 100% RH |
Dimensions (Body) | 3.6 x 0.97" dia. (91.3 x 24.6 mm dia.) |
Weight | 5.5 oz (156 g) |
Material | 316 Stainless Steel/Radel |
Approvals | CE FM Class 3600, latest revision FM Class 3610, latest revision CAN/CSA-C22.2 No. 60079-0:15 CAN/CSA-C22.2 No. 60079-11:14 |