Designed to continuously monitor temperature-sensitive vaccines/pharmaceuticals in refrigerators, freezers, coolers and without the optional glycol bottle, the VTMS can measure and record temperatures as low as -148°F (-100 °C).
Designed to continuously monitor temperature-sensitive vaccines/pharmaceuticals in refrigerators, freezers, coolers and without the optional glycol bottle, the VTMS can measure and record temperatures as low as -148°F (-100 °C).
The wireless vaccine temperature monitoring system has audible and LED alarm indicators.
Features
Applications
Specifications | |
Memory | 16,128 readings (all channels enabled) |
Reading Rate | 1 reading every second up to 1 reading every 24 hours |
Baud Rate | 250,000 |
Cold Junction Compensation | Automatic based on internal channel |
Battery Life | 3 years typical at 1 minute reading rate |
Material | ABS Plastic |
Dimensions | 3 x 3.5 x 0.95" (76.2 x 88.9 x 24.1 mm) - Data logger only |
Operating Environment | -4 to +140°F (-20 to +60°C), 0% RH to 95% RH non-condensing |
Required Interface Package | USB to Mini USB Cable |
Weight | 1.1250 lbs |
Internal Channel Temperature Sensor | Semiconductor |
Internal Channel Temperature Range | -4 to +140°F (-20 to 60°C) |
Internal Channel Temperature Resolution | 0.18°F (0.01°C) |
Internal Channel Temperature Calibrated Accuracy | ±0.5°C (0 to +50°C) |
Remote Channel Temperature Sensor | Type K Thermocouple (Included) |
Remote Channel (Thermocouple) Temperature Range | -148 to +176°F (-100 to +80°C) |
Remote Channel (Glycol Bottle) Temperature Range | -58 to +176°F (-50 to +80°C) |
Remote Channel Temperature Resolution | 0.18°F (0.1°C) |
Remote Channel Temperature Calibrated Accuracy | ±0.5°C |
Specifications | |
Memory | 16,128 readings (all channels enabled) |
Reading Rate | 1 reading every second up to 1 reading every 24 hours |
Baud Rate | 250,000 |
Cold Junction Compensation | Automatic based on internal channel |
Battery Life | 3 years typical at 1 minute reading rate |
Material | ABS Plastic |
Dimensions | 3 x 3.5 x 0.95" (76.2 x 88.9 x 24.1 mm) - Data logger only |
Operating Environment | -4 to +140°F (-20 to +60°C), 0% RH to 95% RH non-condensing |
Required Interface Package | USB to Mini USB Cable |
Weight | 1.1250 lbs |
Internal Channel Temperature Sensor | Semiconductor |
Internal Channel Temperature Range | -4 to +140°F (-20 to 60°C) |
Internal Channel Temperature Resolution | 0.18°F (0.01°C) |
Internal Channel Temperature Calibrated Accuracy | ±0.5°C (0 to +50°C) |
Remote Channel Temperature Sensor | Type K Thermocouple (Included) |
Remote Channel (Thermocouple) Temperature Range | -148 to +176°F (-100 to +80°C) |
Remote Channel (Glycol Bottle) Temperature Range | -58 to +176°F (-50 to +80°C) |
Remote Channel Temperature Resolution | 0.18°F (0.1°C) |
Remote Channel Temperature Calibrated Accuracy | ±0.5°C |