Martel LC-100 Current Loop Calibrator

Model: LC-100 | Order No: 1919053

Martel LC-100 Current Loop Calibrator

Model: LC-100 | Order No: 1919053

This loop calibrator simulates, powers and measures two-wire transmitters. Features a minimum and maximum value recall button and has a high accuracy of ±0.015% of reading.

This loop calibrator simulates, powers and measures two-wire transmitters. Features a minimum and maximum value recall button and has a high accuracy of ±0.015% of reading.

Discontinued!

This product has been discontinued and is no longer available.

There is no direct replacement, however we recommend the:

Fluke 705 Loop Calibrator, 0-28 V, .025% Accuracy-

Fluke 705 Loop Calibrator, 0-28 V, .025% Accuracy

Model: 705

Large display and simple, quick-click interface for easy one-handed operation. Simultaneous mA and % readout for quick, easy interpretation of readings.


Fluke 707 Loop Calibrator, 0-28 V, .015% Accuracy-

Fluke 707 Loop Calibrator, 0-28 V, .015% Accuracy

Model: 707

Loop calibrator is ideal for calibration, repair and maintenance of current loops.


Not what you're looking for? Let’s do a search and help you find what you need.


Martel LC-100 Current Loop Calibrator Offers

The current loop calibrator provides significantly extended performance when compared to any competitive current calibrator. With an accuracy of 0.015% and a 0.001mA resolution, the 4-20ma calibrator has the highest accuracy in its class. Unique Features: such as a % Error function, which eliminates manual error calculation and allows the display of the actual versus ideal error at any calibration point, puts this current calibrator way beyond similar instruments. The loop calibrator can simulate, power, and measure two-wire transmitters.

Features

  • High accuracy of ±0.015%
  • High resolution of 0.001mA/0.001V
  • % Error Function eliminates manual error calculation
  • Extended Adjustment Range - digital knob and user-selectable decade output allow both large and incremental (0.001 mA step) output changes
  • Reads 0 to 28.0 VDC
  • Built-in 250 Ohm Resistor facilitates calibration of Hart Devices
  • Automatic Step and Ramp functions allow for Remote Calibrations
  • Loop Power Measurements
  • Simulates, Powers, and Measures Two-Wire Transmitters
  • Five Push button Preset Outputs (4, 8, 12, 16, 20 mA)
  • Fuseless Input Protection up to 250 VAC
  • Includes neoprene sleeve, NIST Certificate with calibration data

Applications

Ideal for the following applications: Process Technology, Control Valve Testing, Automation and Control.

Martel LC-100 Specifications

Input Function Current Range 0.000 to 24.000mA, -25.00 to 125.00%
Input Function Voltage Range 0 to 28VDC
Output Function
Source/Simulate Range 0.000 to 24.000mA; -25.00 to 125.00%
Drive Capability With out Hart: 1200Ω
With Hart: 950Ω
Loop Supply Voltage 24VDC
Range Select Decade Incremental to 0.001mA steps

What's included with the Martel LC-100

  • LC-100 Loop Calibrator
  • Test Leads
  • 9V Battery
  • Rubber Boot

Ask a question about Martel LC-100 Current Loop Calibrator

Customer Reviews for the Martel LC-100

Martel LC-100 Current Loop Calibrator Offers

The current loop calibrator provides significantly extended performance when compared to any competitive current calibrator. With an accuracy of 0.015% and a 0.001mA resolution, the 4-20ma calibrator has the highest accuracy in its class. Unique Features: such as a % Error function, which eliminates manual error calculation and allows the display of the actual versus ideal error at any calibration point, puts this current calibrator way beyond similar instruments. The loop calibrator can simulate, power, and measure two-wire transmitters.

Features

  • High accuracy of ±0.015%
  • High resolution of 0.001mA/0.001V
  • % Error Function eliminates manual error calculation
  • Extended Adjustment Range - digital knob and user-selectable decade output allow both large and incremental (0.001 mA step) output changes
  • Reads 0 to 28.0 VDC
  • Built-in 250 Ohm Resistor facilitates calibration of Hart Devices
  • Automatic Step and Ramp functions allow for Remote Calibrations
  • Loop Power Measurements
  • Simulates, Powers, and Measures Two-Wire Transmitters
  • Five Push button Preset Outputs (4, 8, 12, 16, 20 mA)
  • Fuseless Input Protection up to 250 VAC
  • Includes neoprene sleeve, NIST Certificate with calibration data

Applications

Ideal for the following applications: Process Technology, Control Valve Testing, Automation and Control.

Martel LC-100 Specifications

Input Function Current Range 0.000 to 24.000mA, -25.00 to 125.00%
Input Function Voltage Range 0 to 28VDC
Output Function
Source/Simulate Range 0.000 to 24.000mA; -25.00 to 125.00%
Drive Capability With out Hart: 1200Ω
With Hart: 950Ω
Loop Supply Voltage 24VDC
Range Select Decade Incremental to 0.001mA steps

What's included with the Martel LC-100

  • LC-100 Loop Calibrator
  • Test Leads
  • 9V Battery
  • Rubber Boot

Ask a question about Martel LC-100 Current Loop Calibrator

Customer Reviews for the Martel LC-100

More Martel Products

Calibration Lab