Mitutoyo 64PKA117 Laser Scan Micrometer Package, 0.0002 to 0.08"

Model: 64PKA117

Mitutoyo 64PKA117 Laser Scan Micrometer Package, 0.0002 to 0.08"

Model: 64PKA117

Features a non-contact measuring system that combines high-rate scanning with highly accurate measurement.

Features a non-contact measuring system that combines high-rate scanning with highly accurate measurement.

Sale Price $6837.74 USD
Regular Price $11900.00 USD
Availability 2 to 3 Weeks
Quantity

Mitutoyo 64PKA117 Offers

Measuring unit features

  • Permits measurements starting from ⌀ 5 μm
  • Provides ultra-high accuracy with a linearity of °0.3 μm over the entire measurement range (5 μm to 2 mm)
  • Ultra-high repeatability of °0.03 μm
  • Ultra-high scanning rate of 3200 scans/sec
  • Certified accuracy over entire measurement range
  • Improved resistance to IP64-level environments

Display unit features

  • With a dual-display design setup values can be continuously monitored, and two measurement value items can be displayed on the sub-display with the simultaneous measurement function
  • Either segment measurement (7 segments maximum) or edge measurement (1 to 255 edges) can be selected
  • RS-232C and I/O-Analog interfaces are provided as standard
  • A statistical calculation function and abnormal data eliminating function are provided

Applications

  • In-line glass fiber or fine wire diameter
  • Outer diameter of opaque or transparent cylinders
  • Outer diameter and roundness of cylinder
  • X- and Y-axis electric cables and fibers
  • Thickness of film and sheet
  • Spacing of IC chip leads
  • Film sheet thickness
  • Disk head movement
  • Gap between rollers
  • Taper and form
  • Tape width
  • Outer diameter of optical connector and ferrule
  • Dual system for measuring a large outside diameter

Display unit functions

Measuring setup memory

The measuring setup can be registered as a program and saved (100 programs). These programs can be recalled with a single operation.

Multiple calibration data memory function

This function allows storage of 10 types of calibration data. In this function mode, up to 10 sets of 10 programs are available in hand.

Drill/endmill (odd number flute) diameter measurement

The diameter of drills or endmills that have an odd number of flutes can be measured by changing the parameter set up.

Automatic workpiece detection

This function automatically starts measurement when a workpiece advances into the specified measuring area.

Preset/offset

Sets the currently displayed measurement value to zero or a specified numeric value. This is useful, for example, if a difference in the diameters of a reference gage and a workpiece is to be allowed for in calibration, or if a dimension of a workpiece that exceeds the measurement range of the laser scan micrometer is to be measured.

Mastering

For continuous processing of high-precision workpieces, fine-adjusting the preset or offset value is called mastering. By specifying a mastering value, the total correction will be (zero-set/offset value) + (°mastering value). If a positive mastering value is specified, the displayed value for a workpiece diameter measurement will be greater than the actual value. If a negative value is specified, the displayed value will be smaller than the actual value.

Sample measurement

On a sample measurement the number of measurements will be defined (in the range of 2 to 999) in advance. From this sample, measurement various calculation results (mean, maximum, minimum, and range) can be derived. These measurements can be used for runout measurements on a revolving workpiece and simplified cylindricity measurements.

Arithmetical average/moving average

Arithmetical/moving average modes are provided to obtain the average of measurement values. On this type of laser scan micrometer, either of them can be specified before starting measurement. In the arithmetical average mode, the number of scans over which to take an averaging can be set at one of twelve steps between 1 (0.32 ms) and 2048 (0.64 sec). In the moving average mode, the number of scans can be set at one of seven steps between 32 (0.01 sec) and 2048 (0.64 sec), and the measurement value will be updated every sixteen scans on and after the second measurement, irrespective of the specified number of scans for averaging. The latter mode is suitable for judging the trend in the diameter or width of an endless workpiece, such as wire or tape from a measurement that requires a long period.

Measurement using segment specification

The following conventions are used to set up to the maximum of seven segments. However, if the transparent object measuring mode is set, no more than three segments can be set at one time.

Automatic measurement using edges

The edges created by scanning a workpiece can be used to program an laser scan micrometer. A maximum of 127 workpiece features, and 127 of the spaces between these features, can be used, which involves a total of 255 edges. This is most useful for measuring such things as IC chip leads or connector pins that are approximately equally spaced. This method cannot be applied to transparent objects.

External trigger signal input

By supplying a contact signal to the foot switch connector at the rear panel of the display unit, the measurement can be triggered.

Abnormal data elimination

If a piece of data significantly exceeds the tolerance limit because the workpiece or measuring unit is contaminated by a water droplet, oil droplet or dust, the piece of data will be automatically removed by this function.

Data output internal setting

By setting an interval (between 1 and 999 seconds) to continuous measurement in advance, data output will take place at each specified period of time.

Statistical calculation

With this function, multiple measurements are taken from the same type of workpiece, statistical values are calculated from the measurement results and quality evaluation is executed for each lot.

Data output

It has a standard RS-232C interface unit, allowing data to be output to an external PC or printer. Additionally, it has the standard I/O-Analog output interface that allows the laser scan micrometer to be connected to a sequencer, etc.

Multi-limit judgment

In addition to +NG, GO, and -NG judgment criteria limit values from Limit 1 to Limit 6 can also be set. If an optional 2nd I/O-Analog interface unit (02AGC880) is used with the display unit, seven-step judgment signals can be output to external devices to support go/no-go judgment.

Simultaneous (dual-program) measurement

It is possible to measure two items simultaneously with one laser scan micrometer unit, and to output the data. This function can be used to simultaneously measure the outside diameter and runout of a bar that is rotating, or to measure the outside diameters of two cylinders or wires at the same time.

Mitutoyo 64PKA117 Specifications

Acceptable Standard of Laser IEC, FDA
Measuring Range .0002 to .08" (0.005 to 2mm)
Resolution (Selectable) .000001 to .0005" (0.00001 to 0.01mm)
Repeatability ±0.03 μm (±1.1μinch)
Linearity at 20°C ±0.3 μm (±12 μinch)
Positional Error ±0.4 μm (±16 μinch)
Measuring Region .04 x.08" (1 x 2 mm)
Scanning Rate 3200 scans/s
Laser Wavelength 650 nm, visible
Laser Scanning Speed 3000"/s (76 m/s)
Operating Temperature 32 to 104°F (0 to 40°C)
Operating Humidity 35 to 85% RH (with no condensation)
Water/Dust protection grade Conforming to IP64
Weight Measuring unit: 2.2 lbs (1.0 kg)
Signal cable: 1.1lbs (0.5 kg)
Display unit: 11 lbs (5 kg)
Click here for complete specifications on the Mitutoyo 64PKA117

What's included with the Mitutoyo 64PKA117

  • Laser Scan Micrometer
  • Display Unit

Click on a category to view a selection of compatible accessories with the Mitutoyo 64PKA117 Laser Scan Micrometer Package, 0.0002 to 0.08".

Mitutoyo 02AGD110 Calibration Gage Kit for the LSM-500S 02AGD110
Functions with the LSM-500S laser scan micrometer, this calibration gauge set consists of precision disks, cylinders, or wires and can function for both types of wire guiding pulleys. This kit comes equipped with 2 x gauges, a gauge stand, and a set case.




Mitutoyo 02AGD200 Wire Guiding Pulley 02AGD200
For use with the laser scan micrometer.




Ask a question about Mitutoyo 64PKA117 Laser Scan Micrometer Package, 0.0002 to 0.08"

Customer Reviews for the Mitutoyo 64PKA117

Mitutoyo 64PKA117 Offers

Measuring unit features

  • Permits measurements starting from ⌀ 5 μm
  • Provides ultra-high accuracy with a linearity of °0.3 μm over the entire measurement range (5 μm to 2 mm)
  • Ultra-high repeatability of °0.03 μm
  • Ultra-high scanning rate of 3200 scans/sec
  • Certified accuracy over entire measurement range
  • Improved resistance to IP64-level environments

Display unit features

  • With a dual-display design setup values can be continuously monitored, and two measurement value items can be displayed on the sub-display with the simultaneous measurement function
  • Either segment measurement (7 segments maximum) or edge measurement (1 to 255 edges) can be selected
  • RS-232C and I/O-Analog interfaces are provided as standard
  • A statistical calculation function and abnormal data eliminating function are provided

Applications

  • In-line glass fiber or fine wire diameter
  • Outer diameter of opaque or transparent cylinders
  • Outer diameter and roundness of cylinder
  • X- and Y-axis electric cables and fibers
  • Thickness of film and sheet
  • Spacing of IC chip leads
  • Film sheet thickness
  • Disk head movement
  • Gap between rollers
  • Taper and form
  • Tape width
  • Outer diameter of optical connector and ferrule
  • Dual system for measuring a large outside diameter

Display unit functions

Measuring setup memory

The measuring setup can be registered as a program and saved (100 programs). These programs can be recalled with a single operation.

Multiple calibration data memory function

This function allows storage of 10 types of calibration data. In this function mode, up to 10 sets of 10 programs are available in hand.

Drill/endmill (odd number flute) diameter measurement

The diameter of drills or endmills that have an odd number of flutes can be measured by changing the parameter set up.

Automatic workpiece detection

This function automatically starts measurement when a workpiece advances into the specified measuring area.

Preset/offset

Sets the currently displayed measurement value to zero or a specified numeric value. This is useful, for example, if a difference in the diameters of a reference gage and a workpiece is to be allowed for in calibration, or if a dimension of a workpiece that exceeds the measurement range of the laser scan micrometer is to be measured.

Mastering

For continuous processing of high-precision workpieces, fine-adjusting the preset or offset value is called mastering. By specifying a mastering value, the total correction will be (zero-set/offset value) + (°mastering value). If a positive mastering value is specified, the displayed value for a workpiece diameter measurement will be greater than the actual value. If a negative value is specified, the displayed value will be smaller than the actual value.

Sample measurement

On a sample measurement the number of measurements will be defined (in the range of 2 to 999) in advance. From this sample, measurement various calculation results (mean, maximum, minimum, and range) can be derived. These measurements can be used for runout measurements on a revolving workpiece and simplified cylindricity measurements.

Arithmetical average/moving average

Arithmetical/moving average modes are provided to obtain the average of measurement values. On this type of laser scan micrometer, either of them can be specified before starting measurement. In the arithmetical average mode, the number of scans over which to take an averaging can be set at one of twelve steps between 1 (0.32 ms) and 2048 (0.64 sec). In the moving average mode, the number of scans can be set at one of seven steps between 32 (0.01 sec) and 2048 (0.64 sec), and the measurement value will be updated every sixteen scans on and after the second measurement, irrespective of the specified number of scans for averaging. The latter mode is suitable for judging the trend in the diameter or width of an endless workpiece, such as wire or tape from a measurement that requires a long period.

Measurement using segment specification

The following conventions are used to set up to the maximum of seven segments. However, if the transparent object measuring mode is set, no more than three segments can be set at one time.

Automatic measurement using edges

The edges created by scanning a workpiece can be used to program an laser scan micrometer. A maximum of 127 workpiece features, and 127 of the spaces between these features, can be used, which involves a total of 255 edges. This is most useful for measuring such things as IC chip leads or connector pins that are approximately equally spaced. This method cannot be applied to transparent objects.

External trigger signal input

By supplying a contact signal to the foot switch connector at the rear panel of the display unit, the measurement can be triggered.

Abnormal data elimination

If a piece of data significantly exceeds the tolerance limit because the workpiece or measuring unit is contaminated by a water droplet, oil droplet or dust, the piece of data will be automatically removed by this function.

Data output internal setting

By setting an interval (between 1 and 999 seconds) to continuous measurement in advance, data output will take place at each specified period of time.

Statistical calculation

With this function, multiple measurements are taken from the same type of workpiece, statistical values are calculated from the measurement results and quality evaluation is executed for each lot.

Data output

It has a standard RS-232C interface unit, allowing data to be output to an external PC or printer. Additionally, it has the standard I/O-Analog output interface that allows the laser scan micrometer to be connected to a sequencer, etc.

Multi-limit judgment

In addition to +NG, GO, and -NG judgment criteria limit values from Limit 1 to Limit 6 can also be set. If an optional 2nd I/O-Analog interface unit (02AGC880) is used with the display unit, seven-step judgment signals can be output to external devices to support go/no-go judgment.

Simultaneous (dual-program) measurement

It is possible to measure two items simultaneously with one laser scan micrometer unit, and to output the data. This function can be used to simultaneously measure the outside diameter and runout of a bar that is rotating, or to measure the outside diameters of two cylinders or wires at the same time.

Mitutoyo 64PKA117 Specifications

Acceptable Standard of Laser IEC, FDA
Measuring Range .0002 to .08" (0.005 to 2mm)
Resolution (Selectable) .000001 to .0005" (0.00001 to 0.01mm)
Repeatability ±0.03 μm (±1.1μinch)
Linearity at 20°C ±0.3 μm (±12 μinch)
Positional Error ±0.4 μm (±16 μinch)
Measuring Region .04 x.08" (1 x 2 mm)
Scanning Rate 3200 scans/s
Laser Wavelength 650 nm, visible
Laser Scanning Speed 3000"/s (76 m/s)
Operating Temperature 32 to 104°F (0 to 40°C)
Operating Humidity 35 to 85% RH (with no condensation)
Water/Dust protection grade Conforming to IP64
Weight Measuring unit: 2.2 lbs (1.0 kg)
Signal cable: 1.1lbs (0.5 kg)
Display unit: 11 lbs (5 kg)
Click here for complete specifications on the Mitutoyo 64PKA117

What's included with the Mitutoyo 64PKA117

  • Laser Scan Micrometer
  • Display Unit

Click on a category to view a selection of compatible accessories with the Mitutoyo 64PKA117 Laser Scan Micrometer Package, 0.0002 to 0.08".

Mitutoyo 02AGD110 Calibration Gage Kit for the LSM-500S 02AGD110
Functions with the LSM-500S laser scan micrometer, this calibration gauge set consists of precision disks, cylinders, or wires and can function for both types of wire guiding pulleys. This kit comes equipped with 2 x gauges, a gauge stand, and a set case.




Mitutoyo 02AGD200 Wire Guiding Pulley 02AGD200
For use with the laser scan micrometer.




Ask a question about Mitutoyo 64PKA117 Laser Scan Micrometer Package, 0.0002 to 0.08"

Customer Reviews for the Mitutoyo 64PKA117

More Mitutoyo Products

Calibration Lab