This pressure transducer has a pressure rating of 0 psig to 200 psig, ± 0.5 % full scale (BFSL) accuracy and 1/4" NPT Hirschmann connections.
This pressure transducer has a pressure rating of 0 psig to 200 psig, ± 0.5 % full scale (BFSL) accuracy and 1/4" NPT Hirschmann connections.
NOSHOK 300 Series Compact OEM Transducers with ranges from 0 psig to 15 through 0 psig to 10,000 psig; absolute ranges from 0 psia to 15 psia through 0 psia to 300 psia.
Features
Applications
Pressure ranges | 0 psig to 15 psig through 0 psig to 10,000 psig Absolute from 0 psia to 15 psia through 0 psia to 300 psia |
Accuracy | ±0.5% full scale (BFSL); optional ±0.25% full scale (BFSL); (includes the effects of non-linearity, hysteresis, non-repeatability, zero point and full scale errors) |
Stability | ≤ ±0.2% full scale per year, non-accumulating |
Response time | ≤ 4 ms (between 10% and 90% full scale) |
Pressure cycle limit | 150 Hz |
Durability | > 100,000,000 full scale cycles |
Temperature ranges | Compensated 32 to 176°F (0 to 80°C) Media 32 to 176 °F (0 to 80 °C) Ambient 32 to 176 °F (0 to 80 °C) Storage -4 to 176 °F (0 to 80 °C) |
Load limitations | ≤ (Vpower-10)/0.020 Amp for 4 mA to 20 mA output ≤ 5,000 ohm for 1 Vdc to 5 Vdc output ≤ 10,000 ohm for 0 Vdc to 10 Vdc output ≤ 4,500 ohm for 0.5 Vdc to 4.5 Vdc output |
Proof pressure | 2 times full scale |
Burst pressure | 6 times full scale |
Measuring element | 316 stainless steel for absolute through 150 psi 13-8PH stainless steel for ≥150 psi |
Connection | 316 stainless steel |
Housing material | 316 stainless steel |
Environmental rating | IP65 to IP67 depending on electrical connection |
Electromagnetic rating | CE compliant to EMC norm EN 61326:1997/A1:1998 RFI, EMI and ESD protection |
Electrical protection | Reverse polarity, over-voltage and short circuit protection |
Shock | 500 g's according to IEC 60068-2-27 |
Vibration | 10 g's according to IEC 60068-2-6 |
Weight | Approximately 2.8 oz |
Pressure ranges | 0 psig to 15 psig through 0 psig to 10,000 psig Absolute from 0 psia to 15 psia through 0 psia to 300 psia |
Accuracy | ±0.5% full scale (BFSL); optional ±0.25% full scale (BFSL); (includes the effects of non-linearity, hysteresis, non-repeatability, zero point and full scale errors) |
Stability | ≤ ±0.2% full scale per year, non-accumulating |
Response time | ≤ 4 ms (between 10% and 90% full scale) |
Pressure cycle limit | 150 Hz |
Durability | > 100,000,000 full scale cycles |
Temperature ranges | Compensated 32 to 176°F (0 to 80°C) Media 32 to 176 °F (0 to 80 °C) Ambient 32 to 176 °F (0 to 80 °C) Storage -4 to 176 °F (0 to 80 °C) |
Load limitations | ≤ (Vpower-10)/0.020 Amp for 4 mA to 20 mA output ≤ 5,000 ohm for 1 Vdc to 5 Vdc output ≤ 10,000 ohm for 0 Vdc to 10 Vdc output ≤ 4,500 ohm for 0.5 Vdc to 4.5 Vdc output |
Proof pressure | 2 times full scale |
Burst pressure | 6 times full scale |
Measuring element | 316 stainless steel for absolute through 150 psi 13-8PH stainless steel for ≥150 psi |
Connection | 316 stainless steel |
Housing material | 316 stainless steel |
Environmental rating | IP65 to IP67 depending on electrical connection |
Electromagnetic rating | CE compliant to EMC norm EN 61326:1997/A1:1998 RFI, EMI and ESD protection |
Electrical protection | Reverse polarity, over-voltage and short circuit protection |
Shock | 500 g's according to IEC 60068-2-27 |
Vibration | 10 g's according to IEC 60068-2-6 |
Weight | Approximately 2.8 oz |