Suitable for pipe mounting, this sensor offers integrated strain relief, so the probe is secured to the logger and features Self-Describing technology to automatically communicate configuration information to the logger. It works with analog/temperature/RH/light, and four-channel analog data loggers.
Suitable for pipe mounting, this sensor offers integrated strain relief, so the probe is secured to the logger and features Self-Describing technology to automatically communicate configuration information to the logger. It works with analog/temperature/RH/light, and four-channel analog data loggers.
Features
Applications
Measurement Range | -40 to 212°F (-40 to 100°C) |
Accuracy | ±0.27°F from 32 to 122°F (±0.15°C from 0 to 50°C), insert probe 0.9" (2.3 cm) minimum |
Resolution | 0.003 at 77°F (0.002 at 25°C) |
Drift | <0.2°F (<0.1°C) per year |
Response Time In Air: 2 minutes typical to 90% in air moving 1 m/s (2.2 mph) On a Pipe: Typically 2 times faster ; typically less than 1 minute to 90% |
|
Probe | Dimensions: 0.38 x 2.3" (0.9 x 5.8 cm) Housing: Copper-plated sensor tip |
Cable Length | 6' (1.8 m) |
Measurement Range | -40 to 212°F (-40 to 100°C) |
Accuracy | ±0.27°F from 32 to 122°F (±0.15°C from 0 to 50°C), insert probe 0.9" (2.3 cm) minimum |
Resolution | 0.003 at 77°F (0.002 at 25°C) |
Drift | <0.2°F (<0.1°C) per year |
Response Time In Air: 2 minutes typical to 90% in air moving 1 m/s (2.2 mph) On a Pipe: Typically 2 times faster ; typically less than 1 minute to 90% |
|
Probe | Dimensions: 0.38 x 2.3" (0.9 x 5.8 cm) Housing: Copper-plated sensor tip |
Cable Length | 6' (1.8 m) |