Supports up to 3 separate 120 VAC single-phase branch circuits or individual 120 VAC phases of a 3-phase Wye-connection 208/240 VAC circuit. Provides accurate measurement at low cost to meet your needs for sub-metering, net-metering, energy management, and performance contracting applications. Works with Magnelab AC Current Transformers and a Pulse Input Adapter or a Data Node pulse input port to provide True RMS kilowatt hours of energy used, even for loads with non-sinusoidal waveforms.
Supports up to 3 separate 120 VAC single-phase branch circuits or individual 120 VAC phases of a 3-phase Wye-connection 208/240 VAC circuit. Provides accurate measurement at low cost to meet your needs for sub-metering, net-metering, energy management, and performance contracting applications. Works with Magnelab AC Current Transformers and a Pulse Input Adapter or a Data Node pulse input port to provide True RMS kilowatt hours of energy used, even for loads with non-sinusoidal waveforms.
This WattNode kWh Transducer works with Magnelab AC Current Transformers and a Pulse Input Adapter, or a HOBO® Data Node pulse input port to provide True RMS kilowatt hours of energy used, even for loads with non-sinusoidal waveforms. Because these sensors tie directly into the line, they should be used only by qualified personnel. This model supports up to 3 separate 120 VAC single-phase branch circuits or individual 120 VAC phases of a 3-phase wye-connection 208/240 VAC circuit.
Features
Applications
Wye Configuration Ranges | 120, 208, 240 Volts AC - Neutral Required 1 Phase 2 Wire 120V (With Neutral) 1 Phase 3 Wire 120V/240V 3 Phase 4 Wire 120V/208V |
Operating | Voltage Range: ±20% of Nominal |
Frequency | 60 Hz |
CT Input | 0-0.5 VAC Operating, 3 VAC Maximum |
Accuracy | ±0.45% of Reading + 0.05% FS Through 25th Harmonic (Dependent on CT Used and Line Variation Accuracy Could Be 1.5% to 4% of Reading) |
Enclosure | High Impact, UL Rated ABS Plastic |
Connectors | UL, cUL Recognized, Detachable Screw Terminals (14 AWG), 600V |
Operating Temperature Range | -30 to 60°C (-22 to 140°F) |
Operating Humidity Range | 0 to 90% RH, Non-Condensing |
Dimensions | 8.5 x 14.3 x 3.8 cm (3.3 x 5.6 x 1.5") |
Weight | 295 g (10.4 oz.) |
Number of Data Channels | 3 |
Wye Configuration Ranges | 120, 208, 240 Volts AC - Neutral Required 1 Phase 2 Wire 120V (With Neutral) 1 Phase 3 Wire 120V/240V 3 Phase 4 Wire 120V/208V |
Operating | Voltage Range: ±20% of Nominal |
Frequency | 60 Hz |
CT Input | 0-0.5 VAC Operating, 3 VAC Maximum |
Accuracy | ±0.45% of Reading + 0.05% FS Through 25th Harmonic (Dependent on CT Used and Line Variation Accuracy Could Be 1.5% to 4% of Reading) |
Enclosure | High Impact, UL Rated ABS Plastic |
Connectors | UL, cUL Recognized, Detachable Screw Terminals (14 AWG), 600V |
Operating Temperature Range | -30 to 60°C (-22 to 140°F) |
Operating Humidity Range | 0 to 90% RH, Non-Condensing |
Dimensions | 8.5 x 14.3 x 3.8 cm (3.3 x 5.6 x 1.5") |
Weight | 295 g (10.4 oz.) |
Number of Data Channels | 3 |