Ralston QTCM-1KPSIG-FL QSCM Calibration Manifold Kit, 1,000 psi

Model: QTCM-1KPSIG-FL

Ralston QTCM-1KPSIG-FL QSCM Calibration Manifold Kit, 1,000 psi

Model: QTCM-1KPSIG-FL

Use the calibration kit and nitrogen to perform static pressure calibrations. The kit comes with a calibration manifold, pressure gauge, hoses and more.

Use the calibration kit and nitrogen to perform static pressure calibrations. The kit comes with a calibration manifold, pressure gauge, hoses and more.

Your Price $3117.94 USD
Availability 2 to 3 Weeks
Quantity

Ralston QTCM-1KPSIG-FL Offers



Take advantage of the Ralston QTCM-1KPSIG-FL QSCM Calibration Manifold Kit to perform static pressure calibrations. The kit comes with a variety of hoses, connections, a pressure gauge and a calibration manifold to help your task go smoothly.

Features

  • Calibration manifold handles up to 3,000 psi (200 bar) of pressure and offers 0.01 psi (0.07 mbar) fine adjustment resolution
  • Manifold works in temperatures from 0 to 130°F (-18 to 54°C) and is designed for use with air, inert gas and natural gas
  • Manifold is equipped with male Quick-Test connections
  • Anodized aluminum and brass construction of the manifold provides durability
  • Pressure FieldLab handles up to 1,000 psi, 70 bar or 7 MPa and withstands temperatures from 14 to 122°F (-10 to 50°C)
  • FieldLab is designed for use with air, inert gas, natural gas, petroleum-based oil and water to gauge pressure
  • View the results on the 3.5" (90 mm) color TFT LCD
  • Boasts atm, bar, cmH2O @4°C, inH2O @39°C, kPa, MPa, mbar, psi, inHg @39°F, kgf / cm², mmHg @0°C, Torr, ftH2O @39°F, cmHg @ 0°C and oz / in² engineering units
  • Transfer data to your PC using the USB connection
  • 0.25" (6.4 mm) male NPT x male Quick-Test process connections handle up to 5,000 psi and operate in temperatures from 0 to 225° (-18 to 105°C)
  • Process connections are constructed of brass and feature Buna-N seals for durability
  • 20' (6.1 m) and 2' (0.6 m) hoses boast female Quick-Test ends for simple setup, and the hose is built to withstand pressure of 6,900 psi
  • IP67 ingress protection to withstand water submersion
  • Made in the USA

Ralston QTCM-1KPSIG-FL Specifications


Product HeightManifold: 2.3" (59 mm); Pressure reference: 2.5" (64 mm); Bag: 9" (23 cm)
Product TypeCalibration kit
Number Of Batteries Required1
Application(s)Perform accurate static pressure calibrations
Rechargeable BatteryYes
ApprovalsCSA Standard C22.2 No. 61010-1, UL / IEC / EN / AS Standard No. 61010-1, North America - Class 1 Division 1 Groups A-D, T4, (-10 < Ta < 50°C), ATEX - Ex II 1 G Ex ia IIC T4 Ga (-10 < Ta < 50°C), IECEx - Ex ia IIC T4 Ga (-10 < Ta < 50°C), UN/DOT 38.3 (Lithium Batteries), Pressure Equipment Directive 2014/68/EU, Low Voltage Directive 2014/35/EU, Electromagnetic Compatibility Directive 2014/30/EU
Item(s) IncludedCalibration manifold, Pressure FieldLab with bottom connection, 0.25" (6.4 mm) male NPT x male Quick-Test process connection, 2' (61 cm) Quick-Test hose, 20' (6.1 m) Quick-Test hose, FieldLab AC power charger kit, 6.6' (2 m) USB cable, Carrying case, Zippered bag
MaterialMetal
Power SourceBattery powered
Battery Life1,000 hours
Product LengthManifold: 3.8" (97 mm); Pressure reference: 9" (23 cm); Process connection: 1.29" (33 mm); Hoses: 20' (7 m), 2' (0.6 m); Bag: 10" (26 cm)
Product WidthManifold: 5.1" (13 cm); Pressure reference: 5" (13 cm); Process connection: 0.56" (15 mm); Bag: 2" (51 mm)
Product WeightManifold: 2.2 lbs (1,000 g); Pressure reference: 2.56 lbs (1.16 kg); Bag: 3 oz (85 g)
Click here for complete specifications on the Ralston QTCM-1KPSIG-FL

What's included with the Ralston QTCM-1KPSIG-FL


  • NIST-Traceable FLP1 FieldLab Calibration Certificate
  • QSCM Calibration Manifold
  • FLP1-GP-QF Pressure FieldLab Pressure Reference
  • 2 x QTHA-2MB0 0.25" (6.4 mm) Male NPT x Male Quick-Test Process Connections
  • QTQT-HOS-20ft 20' (6.1 m) Quick-Test Hose
  • QTQT-HOS-2ft 2' (61 cm) Quick-Test Hose
  • DGAU-0191 6.6' (2 m) USB Cable
  • DGAU-0163 FieldLab AC Power Charger Kit
  • SM-0027 Zippered Bag
  • DGAU-0370 FieldLab Carrying Case

How to set up and operate the Ralston QTCM and QSCM calibration manifold


In this training video, you'll learn how to set up and operate the QTCM and QSCM calibration manifolds for reducing leaks, saving you time. Rugged, portable, and handheld, these calibration manifolds are ideal for field calibrating pressure devices and relatively high pressures.

Ask a question about Ralston QTCM-1KPSIG-FL QSCM Calibration Manifold Kit, 1,000 psi

Customer Reviews for the Ralston QTCM-1KPSIG-FL

Ralston QTCM-1KPSIG-FL Offers



Take advantage of the Ralston QTCM-1KPSIG-FL QSCM Calibration Manifold Kit to perform static pressure calibrations. The kit comes with a variety of hoses, connections, a pressure gauge and a calibration manifold to help your task go smoothly.

Features

  • Calibration manifold handles up to 3,000 psi (200 bar) of pressure and offers 0.01 psi (0.07 mbar) fine adjustment resolution
  • Manifold works in temperatures from 0 to 130°F (-18 to 54°C) and is designed for use with air, inert gas and natural gas
  • Manifold is equipped with male Quick-Test connections
  • Anodized aluminum and brass construction of the manifold provides durability
  • Pressure FieldLab handles up to 1,000 psi, 70 bar or 7 MPa and withstands temperatures from 14 to 122°F (-10 to 50°C)
  • FieldLab is designed for use with air, inert gas, natural gas, petroleum-based oil and water to gauge pressure
  • View the results on the 3.5" (90 mm) color TFT LCD
  • Boasts atm, bar, cmH2O @4°C, inH2O @39°C, kPa, MPa, mbar, psi, inHg @39°F, kgf / cm², mmHg @0°C, Torr, ftH2O @39°F, cmHg @ 0°C and oz / in² engineering units
  • Transfer data to your PC using the USB connection
  • 0.25" (6.4 mm) male NPT x male Quick-Test process connections handle up to 5,000 psi and operate in temperatures from 0 to 225° (-18 to 105°C)
  • Process connections are constructed of brass and feature Buna-N seals for durability
  • 20' (6.1 m) and 2' (0.6 m) hoses boast female Quick-Test ends for simple setup, and the hose is built to withstand pressure of 6,900 psi
  • IP67 ingress protection to withstand water submersion
  • Made in the USA

Ralston QTCM-1KPSIG-FL Specifications


Product HeightManifold: 2.3" (59 mm); Pressure reference: 2.5" (64 mm); Bag: 9" (23 cm)
Product TypeCalibration kit
Number Of Batteries Required1
Application(s)Perform accurate static pressure calibrations
Rechargeable BatteryYes
ApprovalsCSA Standard C22.2 No. 61010-1, UL / IEC / EN / AS Standard No. 61010-1, North America - Class 1 Division 1 Groups A-D, T4, (-10 < Ta < 50°C), ATEX - Ex II 1 G Ex ia IIC T4 Ga (-10 < Ta < 50°C), IECEx - Ex ia IIC T4 Ga (-10 < Ta < 50°C), UN/DOT 38.3 (Lithium Batteries), Pressure Equipment Directive 2014/68/EU, Low Voltage Directive 2014/35/EU, Electromagnetic Compatibility Directive 2014/30/EU
Item(s) IncludedCalibration manifold, Pressure FieldLab with bottom connection, 0.25" (6.4 mm) male NPT x male Quick-Test process connection, 2' (61 cm) Quick-Test hose, 20' (6.1 m) Quick-Test hose, FieldLab AC power charger kit, 6.6' (2 m) USB cable, Carrying case, Zippered bag
MaterialMetal
Power SourceBattery powered
Battery Life1,000 hours
Product LengthManifold: 3.8" (97 mm); Pressure reference: 9" (23 cm); Process connection: 1.29" (33 mm); Hoses: 20' (7 m), 2' (0.6 m); Bag: 10" (26 cm)
Product WidthManifold: 5.1" (13 cm); Pressure reference: 5" (13 cm); Process connection: 0.56" (15 mm); Bag: 2" (51 mm)
Product WeightManifold: 2.2 lbs (1,000 g); Pressure reference: 2.56 lbs (1.16 kg); Bag: 3 oz (85 g)
Click here for complete specifications on the Ralston QTCM-1KPSIG-FL

What's included with the Ralston QTCM-1KPSIG-FL


  • NIST-Traceable FLP1 FieldLab Calibration Certificate
  • QSCM Calibration Manifold
  • FLP1-GP-QF Pressure FieldLab Pressure Reference
  • 2 x QTHA-2MB0 0.25" (6.4 mm) Male NPT x Male Quick-Test Process Connections
  • QTQT-HOS-20ft 20' (6.1 m) Quick-Test Hose
  • QTQT-HOS-2ft 2' (61 cm) Quick-Test Hose
  • DGAU-0191 6.6' (2 m) USB Cable
  • DGAU-0163 FieldLab AC Power Charger Kit
  • SM-0027 Zippered Bag
  • DGAU-0370 FieldLab Carrying Case

How to set up and operate the Ralston QTCM and QSCM calibration manifold


In this training video, you'll learn how to set up and operate the QTCM and QSCM calibration manifolds for reducing leaks, saving you time. Rugged, portable, and handheld, these calibration manifolds are ideal for field calibrating pressure devices and relatively high pressures.