Able to convert the input high voltage into low voltage, this high-voltage differential probe displays the waveforms by connecting its output interface to the oscilloscope. With 70 MHz bandwidth, this differential probe meets the requirements of most high-frequency test systems.
Able to convert the input high voltage into low voltage, this high-voltage differential probe displays the waveforms by connecting its output interface to the oscilloscope. With 70 MHz bandwidth, this differential probe meets the requirements of most high-frequency test systems.
Features
Applications
Bandwidth (-3 dB) | 70 MHz |
Rise Time | ≤5 ns |
Accuracy | ±2% |
Range (Attenuation) | 50X/500X |
Maximum Measurable Differential Voltage (DC + peak AC) | 50X: ±150 V 500X: ±1500 V |
Common Mode Voltage (DC + peak AC) | ±1500 V |
Maximum Input Voltage-to-Earth (Vrms) | 600 V CAT Ⅲ 1000 V CAT Ⅱ |
Input Impedance | Between each input and ground: 5 MΩ ±1% Between differential inputs: 10 MΩ ±1% |
Input Capacitance | Between each input and ground: <4 pF Between differential inputs: <2 pF |
Temperature | Operating: 32 to 122°F (0 to 50°C) Storage: -22 to 158°F (-30 to 70°C) |
Humidity | Operating: ≤85% RH Storage: ≤90% RH |
Altitude | Operating: 9842’ (3000 m) Storage: 39370’ (12,000 m) |
CMRR | DC: >80 dB 100 kHz: >60 dB 1 MHz: >50 dB 3.2 MHz: >30 dB 50 MHz: >26 dB |
Input Referred Noise (Vrms) | 50X: <50 mV 500X: <300 mV |
Overrange Voltage Threshold | 50X: 153 V ±3 V |
Indicator | 500X: 1530 V ±30 V |
Delay | 21 ns |
Bandwidth Limit (5 MHz) | ≥-3 dB at 5 MHz |
Overrange Indicator (Red) | YES |
Audible Overrange Alarm | Yes (ON/Off is available) |
Auto Save | Yes |
Output Impedance | 50 Ω |
Safety Standards | EN61010-1:2010 |
Dimensions | Probe: 6.9 x 2.5 x 0.9" (176 x 65 x 25 mm) Insulated plunger hook clip: 5.9 x 1.9 x 0.5" (152 mm x 50 mm x 13 mm) Alligator clip: 0.6 x 1.6 x 0.6" (106 mm x 43 mm x 16 mm) |
Cable Length | High-voltage differential input cable: 11" (28 cm) Probe Output: 39" (1 m) |
Bandwidth (-3 dB) | 70 MHz |
Rise Time | ≤5 ns |
Accuracy | ±2% |
Range (Attenuation) | 50X/500X |
Maximum Measurable Differential Voltage (DC + peak AC) | 50X: ±150 V 500X: ±1500 V |
Common Mode Voltage (DC + peak AC) | ±1500 V |
Maximum Input Voltage-to-Earth (Vrms) | 600 V CAT Ⅲ 1000 V CAT Ⅱ |
Input Impedance | Between each input and ground: 5 MΩ ±1% Between differential inputs: 10 MΩ ±1% |
Input Capacitance | Between each input and ground: <4 pF Between differential inputs: <2 pF |
Temperature | Operating: 32 to 122°F (0 to 50°C) Storage: -22 to 158°F (-30 to 70°C) |
Humidity | Operating: ≤85% RH Storage: ≤90% RH |
Altitude | Operating: 9842’ (3000 m) Storage: 39370’ (12,000 m) |
CMRR | DC: >80 dB 100 kHz: >60 dB 1 MHz: >50 dB 3.2 MHz: >30 dB 50 MHz: >26 dB |
Input Referred Noise (Vrms) | 50X: <50 mV 500X: <300 mV |
Overrange Voltage Threshold | 50X: 153 V ±3 V |
Indicator | 500X: 1530 V ±30 V |
Delay | 21 ns |
Bandwidth Limit (5 MHz) | ≥-3 dB at 5 MHz |
Overrange Indicator (Red) | YES |
Audible Overrange Alarm | Yes (ON/Off is available) |
Auto Save | Yes |
Output Impedance | 50 Ω |
Safety Standards | EN61010-1:2010 |
Dimensions | Probe: 6.9 x 2.5 x 0.9" (176 x 65 x 25 mm) Insulated plunger hook clip: 5.9 x 1.9 x 0.5" (152 mm x 50 mm x 13 mm) Alligator clip: 0.6 x 1.6 x 0.6" (106 mm x 43 mm x 16 mm) |
Cable Length | High-voltage differential input cable: 11" (28 cm) Probe Output: 39" (1 m) |