Measure temperature with high accuracy and efficiency with this multi-function thermometer which has powerful functions such as data logging, USB connection, peak high and low temperature burnout (sensor broken) display, remaining battery service display, and automatic power off. In addition, it can store up to 9999 logs.
Measure temperature with high accuracy and efficiency with this multi-function thermometer which has powerful functions such as data logging, USB connection, peak high and low temperature burnout (sensor broken) display, remaining battery service display, and automatic power off. In addition, it can store up to 9999 logs.
Features
Applications
Input | Thermocouple K (JIS/IEC) RTD Pt100 |
Range | Thermocouple K: -328 to 1999°F (-200 to 1200°C) RTD/Pt100: -328 to 1562°F (-200 to 850°C) |
Sampling Time | Approximately 0.5 seconds |
Measuring Accuracy | ±(0.1% of indicated value + 1 digit) or ±0.6°F (0.3°C) (whichever is larger) Cold junction temperature error ±0.9°F (0.5°C) [Between 41 and 104°F (5 and 40°C)] Ambient temperature influence ±0.01% of span/°C [Between 41 and 104°F (5 and 40°C)] |
Display | Reflective FSTN LCD |
Data Logging (Recording) | Recording method: Manual log mode: Can be manually recorded in the memory. Interval log mode: Can be automatically recorded (in a set interval) Interval time: 0 (Manual log mode), 1 to 3600 second Recording items: Measured temperature, Date, Time, Tag name, User No. Recording capacity: Maximum 9999 logs Memory backup: Backed up by EEPROM Number of writing: Approximately 100,000 time Data retaining period: Approximately 10 years |
Tag Number Function | Number of maximum registration: 99 tags registration items (Tag name, evaluation points of high and low temperature) Tag name: 11 characters (numeral, alphabets, symbols) Memory backup: Same as Memory backup of data logging |
Function | Peak high and low temperature Measured value hold Burnout (sensor broken) Decimal point selection (0/0.1) Battery low alarm Automatic power off (3 minutes/30 minutes/off) |
Waterproof/Dustproof | IP54 |
Power Supply | Type LR6 (based on IEC and JIS) alkaline battery, One battery Battery life: Approximately 400 hours (Continuous operating time, around the ambient temperature 73.4°F (23°C) |
Ambient Conditions | Temperature: -4 to 122°F (-20 to 50°C) Humidity: 5 to 95% RH (Absolute humidity: Maximum W.C 29 g/m3 dry air at 101.3 kPa.) |
Dimensions | 5.71 x 2.05 x 0.98" (145 x 52 x 25 mm) |
Weight (Net) | 0.33 lbs (150 g) including LR6 alkaline battery |
Input | Thermocouple K (JIS/IEC) RTD Pt100 |
Range | Thermocouple K: -328 to 1999°F (-200 to 1200°C) RTD/Pt100: -328 to 1562°F (-200 to 850°C) |
Sampling Time | Approximately 0.5 seconds |
Measuring Accuracy | ±(0.1% of indicated value + 1 digit) or ±0.6°F (0.3°C) (whichever is larger) Cold junction temperature error ±0.9°F (0.5°C) [Between 41 and 104°F (5 and 40°C)] Ambient temperature influence ±0.01% of span/°C [Between 41 and 104°F (5 and 40°C)] |
Display | Reflective FSTN LCD |
Data Logging (Recording) | Recording method: Manual log mode: Can be manually recorded in the memory. Interval log mode: Can be automatically recorded (in a set interval) Interval time: 0 (Manual log mode), 1 to 3600 second Recording items: Measured temperature, Date, Time, Tag name, User No. Recording capacity: Maximum 9999 logs Memory backup: Backed up by EEPROM Number of writing: Approximately 100,000 time Data retaining period: Approximately 10 years |
Tag Number Function | Number of maximum registration: 99 tags registration items (Tag name, evaluation points of high and low temperature) Tag name: 11 characters (numeral, alphabets, symbols) Memory backup: Same as Memory backup of data logging |
Function | Peak high and low temperature Measured value hold Burnout (sensor broken) Decimal point selection (0/0.1) Battery low alarm Automatic power off (3 minutes/30 minutes/off) |
Waterproof/Dustproof | IP54 |
Power Supply | Type LR6 (based on IEC and JIS) alkaline battery, One battery Battery life: Approximately 400 hours (Continuous operating time, around the ambient temperature 73.4°F (23°C) |
Ambient Conditions | Temperature: -4 to 122°F (-20 to 50°C) Humidity: 5 to 95% RH (Absolute humidity: Maximum W.C 29 g/m3 dry air at 101.3 kPa.) |
Dimensions | 5.71 x 2.05 x 0.98" (145 x 52 x 25 mm) |
Weight (Net) | 0.33 lbs (150 g) including LR6 alkaline battery |