Get a user-friendly, easy-to-use 12 paperless recorder with a 5.7" (14.45 cm) touch screen interface. In addition, it features a simple operation in which the recording starts immediately after pressing the REC button. Allows RS-485 communication and includes relay output.
Get a user-friendly, easy-to-use 12 paperless recorder with a 5.7" (14.45 cm) touch screen interface. In addition, it features a simple operation in which the recording starts immediately after pressing the REC button. Allows RS-485 communication and includes relay output.
Capable of measuring data in real-time on the liquid crystal display, this recorder is a paperless type that can save the measured data to an SD memory card. In addition, it can operate easily with the liquid crystal with the touch panel.
Features
Touch screen operation
User friendly interface through a 5.7" (14.48 cm) LCD touch screen. Most of daily operations are achieved on the touch screen.
Basic display screens
Recording starts immediately after pressing the REC button
Pressing the REC button starts recording. Data is stored into the SD card. With the supplied software, the recorded data can be easily viewed and managed.
Various input methods
Via an external remote AI device (sold separately) and MODBUS master function, external controllers can be connected to the recorder, enabling a maximum of 48 channel recording.
Flexible inputs
Up to 12 analog data can be handled on the main unit.
Math function
In addition to arithmetic operations and totalizing of inputs, the math function enables storage of various computed data such as F-value and DI status.
Lock screen to prevent unintentional operations
Operations via touch screen and front keys can be locked.
Versatile data management function
Comment function allows the user to enter a comment at any time axis. Data management of plural recorders using the supplied software.
Applications
Input | |
Number | 12 points |
Measurement Interval | 100 m second |
Signal | DC voltage, DC current (using external shunt resistor), thermocouple, RTD |
Influence | External resistance (thermocouple): Approximately 0.18 μV/Ω Input lead resistance (RTD): Maximum 5 Ω per wire |
PV Digital Filter | 0 to 99 seconds (OFF when 0 is set) |
Scaling Range | -32,000 to 32,000 (DC voltage, DC current input) Decimal point is programmable |
Unit Sign | Preset units or 20 units (each unit eight characters or less) that can be made |
Square Root Extraction | PV ratio + PV bias |
Math Function | Number of math channel: 36 channels Arithmetic, general, multiplication and F-value calculation can be computed with each math channel The content of the math can be set and be confirmed only with the Parameter Loader Software (standard supplied) |
F-Value Computation Function | F-value of each channel (fatal value of the bacterium by the heating sterilization) is computed from the measurement temperature The content of the computation can be set and be confirmed only with the Parameter Loader Software (standard supplied) |
Recording | |
Memory | External: SD memory card (SD/SDHC) Internal: Approximately 100 MB Capacity: SD: Maximum 2 GB; SDHC: Maximum 32 GB |
Record Data | Main: Trend graph, event data, message data Sub: Trend graph (The record condition can be selected from "sync.", "Alarm", "DI") |
Cycle | Recording: 1 second to 60 minutes (SUB record is possible 100 m second) Data saving: 1 hour to 1 year Data is first saved to the internal memory and then copied to the SD card at the specified cycle. When the internal memory is full or when recording is stopped, data is saved to the SD card. |
Data | Trend: Minimum/maximum/current/average (selectable) value Format: Binary or binary + CSV format (selectable) Other record: Alarm status, message |
Memory Remaining Capacity Display | When the SD card is full, recording is stopped or data can overwrite oldest data (whichever is selected) |
Optional Function Specifications | |
Communication | Type: RS-485 Protocol: Modbus RTU Bit format: Start bit: 1; Data bit: 8; Parity bit: Without, odd or even Communication speed: 9600 bps Maximum connection: 32 units (including host) |
Relay Contact Output | Number of relay contact outputs: 6 points, 250 V AC 3 A, 30 D DC 3 A (3 A/common, Total: <9 A) Output function: Alarm output |
Input | |
Number | 12 points |
Measurement Interval | 100 m second |
Signal | DC voltage, DC current (using external shunt resistor), thermocouple, RTD |
Influence | External resistance (thermocouple): Approximately 0.18 μV/Ω Input lead resistance (RTD): Maximum 5 Ω per wire |
PV Digital Filter | 0 to 99 seconds (OFF when 0 is set) |
Scaling Range | -32,000 to 32,000 (DC voltage, DC current input) Decimal point is programmable |
Unit Sign | Preset units or 20 units (each unit eight characters or less) that can be made |
Square Root Extraction | PV ratio + PV bias |
Math Function | Number of math channel: 36 channels Arithmetic, general, multiplication and F-value calculation can be computed with each math channel The content of the math can be set and be confirmed only with the Parameter Loader Software (standard supplied) |
F-Value Computation Function | F-value of each channel (fatal value of the bacterium by the heating sterilization) is computed from the measurement temperature The content of the computation can be set and be confirmed only with the Parameter Loader Software (standard supplied) |
Recording | |
Memory | External: SD memory card (SD/SDHC) Internal: Approximately 100 MB Capacity: SD: Maximum 2 GB; SDHC: Maximum 32 GB |
Record Data | Main: Trend graph, event data, message data Sub: Trend graph (The record condition can be selected from "sync.", "Alarm", "DI") |
Cycle | Recording: 1 second to 60 minutes (SUB record is possible 100 m second) Data saving: 1 hour to 1 year Data is first saved to the internal memory and then copied to the SD card at the specified cycle. When the internal memory is full or when recording is stopped, data is saved to the SD card. |
Data | Trend: Minimum/maximum/current/average (selectable) value Format: Binary or binary + CSV format (selectable) Other record: Alarm status, message |
Memory Remaining Capacity Display | When the SD card is full, recording is stopped or data can overwrite oldest data (whichever is selected) |
Optional Function Specifications | |
Communication | Type: RS-485 Protocol: Modbus RTU Bit format: Start bit: 1; Data bit: 8; Parity bit: Without, odd or even Communication speed: 9600 bps Maximum connection: 32 units (including host) |
Relay Contact Output | Number of relay contact outputs: 6 points, 250 V AC 3 A, 30 D DC 3 A (3 A/common, Total: <9 A) Output function: Alarm output |