Versatile and microprocessor-controlled, this powerful fixed system controller is simple to install and operate. Compatible with sensors directly for LEL level combustibles, oxygen, hydrogen sulfide, or carbon monoxide, this controller works with any 4 to 20 mA transmitter (two- or three-wire, 24 V DC).
Versatile and microprocessor-controlled, this powerful fixed system controller is simple to install and operate. Compatible with sensors directly for LEL level combustibles, oxygen, hydrogen sulfide, or carbon monoxide, this controller works with any 4 to 20 mA transmitter (two- or three-wire, 24 V DC).
Versatile and microprocessor-controlled, this powerful fixed system controller is simple to install and operate. Compatible with sensors directly for LEL level combustibles, oxygen, hydrogen sulfide, or carbon monoxide, this controller works with any 4 to 20 mA transmitter (two- or three-wire, 24 V DC).
Sensors can be mounted directly at the controller housing or can be wired remote from the controller. In addition, the 10 A rated relay contacts allow direct control of external alarms and horns and the digital display has backlighting and simultaneous readout of the gas type and concentration.
Moreover, this system controller is also housed in a NEMA 4X rated case for a weather tight seal that complies with lock out/tag out standards and can be fully secured. Silence the alarm from outside of the controller housing with the external reset switch.
Features
Applications
Input | |
Direct Wired Sensors | LEL, Oxygen, Carbon Dioxide, and toxic gas sensors Amplifier not required for less than 500' (152.4 m) |
4 to 20 mA Sensors | Accepts any 4 to 20 mA transmitter (24 V DC, 2 or 3 wire) A wide variety of sensors are available with 4 to 20 mA signals Wiring distances up to 8000' (2438.4 m) |
Sampling Methods | Diffusion and sample draw heads available |
Outputs | |
Relays | Three relays - 10 A rating (at 115 V AC), SPDT isolated contacts Two relays for gas alarms and 1 trouble relay Relays fully programmable for increasing or decreasing alarm, latching or self reset, normally energized or normally de-energized, time delay for alarm on and alarm off Relay contacts rated for 10 A at 115/220 V resistive or 10 A at 30 V resistive |
4 to 20 mA | Signal output, 4 to 20 mA (maximum load impedance 500 ω), per channel |
24 V DC | 24 V DC (400 mA maximum) output provided to operate sample drawing adapters or other accessories |
Display | 2 x 8 Alphanumeric display with backlighting |
Audible | Built-in audible alarm, 94 dB, mounted on enclosure Coded output: Pulsing = gas alarm; Steady = fail |
Visual | 3 LED’s on the front cover for alarm status indication, and malfunction |
General Specifications | |
Enclosure | Wall mounting grey polycarbonate with hinged cover Rating: NEMA-4X enclosure, chemical, and weather resistant (suitable for indoor and outdoor installations) Construction (housing): Fiberglass/polyester with lexan window (NEMA 4X) |
Wiring Termination | Screw type terminal block 14 gauge maximum |
Power | Universal 115 V AC and 220 V AC, or 24 V DC nominal, battery backup option available |
Controls | 3 internal push buttons for setup, programming, and calibration 1 external push button for alarm reset |
Temperature | Operating: -4 to 122°F (-20 to 50°C) Storage: -4 to 158°F (-20 to 70°C) |
Environmental Conditions | For indoor or outdoor locations (Type 4X) -4 to 122°F (-20 to 50°C) ambient Maximum relative humidity of 80% Main supply voltage fluctuations not exceeding ±10% of nominal DC supply voltage fluctuations not exceeding ±10% of nominal Overvoltage Category II, Pollution °2 |
User Controls | Three push button control switches One ON/OFF toggle switch One push button reset switch |
Approvals | CSA Certified to CSA C22.2 No. 61010-1-04 and UL 61010-1 |
Dimensions | 7 x 8.5 x 4.3 (178 x 216 x 109 mm) |
Weight | 4.2 lbs (1.9 kg) |
Click on a category to view a selection of compatible accessories with the RKI Beacon 110 Series Single Channel Wall Mount Controller with battery charger, 24 V DC.
Input | |
Direct Wired Sensors | LEL, Oxygen, Carbon Dioxide, and toxic gas sensors Amplifier not required for less than 500' (152.4 m) |
4 to 20 mA Sensors | Accepts any 4 to 20 mA transmitter (24 V DC, 2 or 3 wire) A wide variety of sensors are available with 4 to 20 mA signals Wiring distances up to 8000' (2438.4 m) |
Sampling Methods | Diffusion and sample draw heads available |
Outputs | |
Relays | Three relays - 10 A rating (at 115 V AC), SPDT isolated contacts Two relays for gas alarms and 1 trouble relay Relays fully programmable for increasing or decreasing alarm, latching or self reset, normally energized or normally de-energized, time delay for alarm on and alarm off Relay contacts rated for 10 A at 115/220 V resistive or 10 A at 30 V resistive |
4 to 20 mA | Signal output, 4 to 20 mA (maximum load impedance 500 ω), per channel |
24 V DC | 24 V DC (400 mA maximum) output provided to operate sample drawing adapters or other accessories |
Display | 2 x 8 Alphanumeric display with backlighting |
Audible | Built-in audible alarm, 94 dB, mounted on enclosure Coded output: Pulsing = gas alarm; Steady = fail |
Visual | 3 LED’s on the front cover for alarm status indication, and malfunction |
General Specifications | |
Enclosure | Wall mounting grey polycarbonate with hinged cover Rating: NEMA-4X enclosure, chemical, and weather resistant (suitable for indoor and outdoor installations) Construction (housing): Fiberglass/polyester with lexan window (NEMA 4X) |
Wiring Termination | Screw type terminal block 14 gauge maximum |
Power | Universal 115 V AC and 220 V AC, or 24 V DC nominal, battery backup option available |
Controls | 3 internal push buttons for setup, programming, and calibration 1 external push button for alarm reset |
Temperature | Operating: -4 to 122°F (-20 to 50°C) Storage: -4 to 158°F (-20 to 70°C) |
Environmental Conditions | For indoor or outdoor locations (Type 4X) -4 to 122°F (-20 to 50°C) ambient Maximum relative humidity of 80% Main supply voltage fluctuations not exceeding ±10% of nominal DC supply voltage fluctuations not exceeding ±10% of nominal Overvoltage Category II, Pollution °2 |
User Controls | Three push button control switches One ON/OFF toggle switch One push button reset switch |
Approvals | CSA Certified to CSA C22.2 No. 61010-1-04 and UL 61010-1 |
Dimensions | 7 x 8.5 x 4.3 (178 x 216 x 109 mm) |
Weight | 4.2 lbs (1.9 kg) |
Click on a category to view a selection of compatible accessories with the RKI Beacon 110 Series Single Channel Wall Mount Controller with battery charger, 24 V DC.