RKI SDM-3R Docking and Calibration Station with 2 solenoid

Model: 81-SDM3R203

RKI SDM-3R Docking and Calibration Station with 2 solenoid

Model: 81-SDM3R203

Perform several functions with this docking and calibration station that is capable of charging, calibrating, and bump testing. Additionally, this station features a docking station with two-cylinder inputs and automatically stores all records for future upload to a PC via a USB flash drive.

Perform several functions with this docking and calibration station that is capable of charging, calibrating, and bump testing. Additionally, this station features a docking station with two-cylinder inputs and automatically stores all records for future upload to a PC via a USB flash drive.

Your Price $1940.00 USD
Availability 2 to 3 Weeks
Quantity

RKI 81-SDM3R203 Offers

Intended for use with the GX-3R (Pro) portable gas monitor, this calibration station has three separate gas inputs.

Features

  • Automatically charge, bump test, and/or calibrate
  • Auto on/off of gas detector
  • Multiple modules (10 maximum) can use one set of calibration equipment
  • Save bump test, calibration, and alarm check records to USB flash drive, computer, or network
  • Multiple modules connected to a PC (10 maximum)
  • Automatic calibration/bump test option
  • Configure GX-3R (Pro) parameters
  • Archive bump test, calibration, and alarm check
  • Archive data to network location
  • Software controlled data retrieval
  • Windows 7, 8, and 10 compatible

Stand alone use

This calibration station is a versatile maintenance tool that automates the service of a GX-3R (Pro) portable gas monitor and it can be used as a stand alone device for charging, calibration and bump testing, with all records stored automatically for future upload to a PC via USB flash drive (PC software and flash drive included).

PC-controlled use

Automate how you manage and service GX-3R (Pro) instruments by connecting this calibration station to a computer with a USB cable. With the docking station controller software, you can simultaneously calibrate, bump test, alarm check, archive data, or charge up to ten instruments. You can also download the datalogging history from each instrument into one easy to manage location. These stations can be manifolded together to reduce the number of demand flow regulators gas cylinders required.

RKI 81-SDM3R203 Specifications

Input Power AC Adapter with 100 to 240 V AC, 47 to 63 Hz, 0.4 A input and 5.99 V DC
2 A output provided as standard
Environmental Conditions Temperature: 32 to 104°F (0 to 40°C)
Relative humdity: <95%, non-condensing
For indoor use only
Maximum Number of Records Saved Stand alone: 200 calibrations, or 214 bump tests, or 469 alarm check records
PC program controlled: Unlimited records
5 Ports 3 calibration gas
1 fresh air
1 exhaust
Click here for complete specifications on the RKI 81-SDM3R203

What's included with the RKI 81-SDM3R203

  • Calibration Station
  • 2 x Solenoid
  • Demand Flow Regulator
  • 58 AL Cylinder H2S/CO/CH4/O2
  • Cylinder Holder
  • AC Adapter
  • Flash Drive
  • USB Cable
  • Tubing
  • PC Software for Viewing/Archiving Bump Test
  • Calibration Records
  • Event Data
  • Inlet Air Filter
  • 10' (3 m) Long Exhaust Tube
  • 3' (0.9 m) Long Tube for GAS Fitting

Ask a question about RKI SDM-3R Docking and Calibration Station with 2 solenoid

Customer Reviews for the RKI 81-SDM3R203

RKI 81-SDM3R203 Offers

Intended for use with the GX-3R (Pro) portable gas monitor, this calibration station has three separate gas inputs.

Features

  • Automatically charge, bump test, and/or calibrate
  • Auto on/off of gas detector
  • Multiple modules (10 maximum) can use one set of calibration equipment
  • Save bump test, calibration, and alarm check records to USB flash drive, computer, or network
  • Multiple modules connected to a PC (10 maximum)
  • Automatic calibration/bump test option
  • Configure GX-3R (Pro) parameters
  • Archive bump test, calibration, and alarm check
  • Archive data to network location
  • Software controlled data retrieval
  • Windows 7, 8, and 10 compatible

Stand alone use

This calibration station is a versatile maintenance tool that automates the service of a GX-3R (Pro) portable gas monitor and it can be used as a stand alone device for charging, calibration and bump testing, with all records stored automatically for future upload to a PC via USB flash drive (PC software and flash drive included).

PC-controlled use

Automate how you manage and service GX-3R (Pro) instruments by connecting this calibration station to a computer with a USB cable. With the docking station controller software, you can simultaneously calibrate, bump test, alarm check, archive data, or charge up to ten instruments. You can also download the datalogging history from each instrument into one easy to manage location. These stations can be manifolded together to reduce the number of demand flow regulators gas cylinders required.

RKI 81-SDM3R203 Specifications

Input Power AC Adapter with 100 to 240 V AC, 47 to 63 Hz, 0.4 A input and 5.99 V DC
2 A output provided as standard
Environmental Conditions Temperature: 32 to 104°F (0 to 40°C)
Relative humdity: <95%, non-condensing
For indoor use only
Maximum Number of Records Saved Stand alone: 200 calibrations, or 214 bump tests, or 469 alarm check records
PC program controlled: Unlimited records
5 Ports 3 calibration gas
1 fresh air
1 exhaust
Click here for complete specifications on the RKI 81-SDM3R203

What's included with the RKI 81-SDM3R203

  • Calibration Station
  • 2 x Solenoid
  • Demand Flow Regulator
  • 58 AL Cylinder H2S/CO/CH4/O2
  • Cylinder Holder
  • AC Adapter
  • Flash Drive
  • USB Cable
  • Tubing
  • PC Software for Viewing/Archiving Bump Test
  • Calibration Records
  • Event Data
  • Inlet Air Filter
  • 10' (3 m) Long Exhaust Tube
  • 3' (0.9 m) Long Tube for GAS Fitting