Sleek with a low-profile design, this battery-operated indoor single-gas detector detects O2 with a 0 to 25% range and 0.1% increments. Users are notified by an audible alarm tone and multicolored LED display when abnormal oxygen levels are present. In addition, this detector has a 9.84' (3 m) sensor cable installed.
Sleek with a low-profile design, this battery-operated indoor single-gas detector detects O2 with a 0 to 25% range and 0.1% increments. Users are notified by an audible alarm tone and multicolored LED display when abnormal oxygen levels are present. In addition, this detector has a 9.84' (3 m) sensor cable installed.
For indoor use, this stand-alone monitor detects oxygen (O2) with a range of 0 to 25.0% volume with 0.1% increments.
Features
Applications
Detection Principle | Galvanic cell |
Gas Detected | Oxygen (O2) |
Detection Range | 0 to 25 vol% |
Display Resolution | 0.1 vol% |
Sampling Method | Diffusion or remote sampling method with optional extender cable |
Indication Accuracy | Within ±0.7 vol% |
Response Time/td> | 90% response within 30 seconds |
Alarm Delay Time | Within 5 seconds, after detecting 10 to 11 vol% gas at Oxygen deficiency alarm (18 vol% alarm) |
Alarm Accuracy | Within ±1 vol% of preset alarms |
Alarm Levels | Two preset alarms (L-LL), alarm 1 = 19.0% vol, alarm 2 = 18.0% vol (other settings available) |
Display of Alarm | 1st gas alarm: gas concentration reading blinks or orange light, flashing AL1 light or orange light, buzzer 2nd gas alarm: gas concentration reading blinks or red light, flashing AL2 light or red light, buzzer |
Alarm Method | Latching or non-latching |
Display | Digital LCD (3 digits, 7 segments/Green, Orange, Red) |
Dimensions | 3.15 x 4.72 x 1.2" (80 x 120 x 35.5 mm) |
Weight | 7.05 oz (200 g) |
Detection Principle | Galvanic cell |
Gas Detected | Oxygen (O2) |
Detection Range | 0 to 25 vol% |
Display Resolution | 0.1 vol% |
Sampling Method | Diffusion or remote sampling method with optional extender cable |
Indication Accuracy | Within ±0.7 vol% |
Response Time/td> | 90% response within 30 seconds |
Alarm Delay Time | Within 5 seconds, after detecting 10 to 11 vol% gas at Oxygen deficiency alarm (18 vol% alarm) |
Alarm Accuracy | Within ±1 vol% of preset alarms |
Alarm Levels | Two preset alarms (L-LL), alarm 1 = 19.0% vol, alarm 2 = 18.0% vol (other settings available) |
Display of Alarm | 1st gas alarm: gas concentration reading blinks or orange light, flashing AL1 light or orange light, buzzer 2nd gas alarm: gas concentration reading blinks or red light, flashing AL2 light or red light, buzzer |
Alarm Method | Latching or non-latching |
Display | Digital LCD (3 digits, 7 segments/Green, Orange, Red) |
Dimensions | 3.15 x 4.72 x 1.2" (80 x 120 x 35.5 mm) |
Weight | 7.05 oz (200 g) |