Measure and register gas emissions for long periods with this industrial emissions analyzer, capable of sensing O2 up to 25% volume and CO up to 100,000 ppm. In addition, this analyzer features a built-in printer, a full-color graphic display, and Bluetooth connectivity.
Measure and register gas emissions for long periods with this industrial emissions analyzer, capable of sensing O2 up to 25% volume and CO up to 100,000 ppm. In addition, this analyzer features a built-in printer, a full-color graphic display, and Bluetooth connectivity.
Features
Windows software Seitron Smart Analysis
Applications
O2 | 0 to 25% volume |
High Range CO Sensor | 0 to 100,000 ppm |
Autozero | Automatic autozero cycle with gas sampling probe in stack |
Fuel Type | 12 preprogrammed and 16 additional programmable by the user |
Temperature | Working: 23 to 113°F (-5 to 45°C) Storage: -4 to 122°F (-20 to 50°C) |
Probe | 12" (300 mm) probe, 1112°F (600°C) maximum, with 10' (3 m) |
Cooler Sample Treatment | Drying system: Rapid water condensation using cyclone system Type: Peltier cell Set point temperature cooler: 41°F (5°C) Maximum tempersture deviation from set point: 50°F (10°C) from set point Condensate emptying pump: Peristaltic hose 38 ml/minute Peristaltic duty cycle pump: 30 seconds On to 30 seconds Off Warm-up time: Aproximately 15 to 20 minutes Operating temperature: 23 to 113°F (-5 to 45°C) |
Anti-Condensation Trap | Type: Integrated Condensate emptying pump: Peristaltic hose 38 ml/minute Operating temperature: 23 to 113°F (-5 to 45°C) |
Printer | Integrated, thermal, with easy paper loading and paper level indicator Power supply: Analyzer batteries Battery life: With fully charged batteries up to 40 analysis reports |
Internal Data Memory | 16,000 complete data analysis, time and customer's name can be stored |
In-Line Filter | With replaceable cartridge, 99% efficiency with 20 μm particles |
Pump | Vacuum: 2 l/minute flow rate in the stack up to 120 in H2O (300 hPa) head Capacity: Internal sensor measuring pump flow rate |
Humidity Limit | 20 to 80% RH |
Self Diagnostics | Check all functions and internal sensors with status indication |
Temperature Measurement | TcK double input with mini connector (ASTM E 1684-96) for temperature Differential measurement (supply and return) |
Ambient Temperature Measurement | Via internal sensor or T2 TcK input with remote sensor |
Autozero | Automatic autozero cycle with gas sampling probe in stack |
Protection Level | IP21 |
Connectivity | Communication port: Type B USB connector Bluetooth: Communication distance: <328.08' (<100 m), open field |
Display | Backlit TFT graphical colour display 4.3" (10.92 cm) 480 x 272 pixels |
Power | Supply: Li-ion battery pack with internal protection circuit, rechargeable Battery charge: Eight hours from 0 to 90% Charging time: 10 hours of continuous operation (except printer) Instrument battery life: Two hours with cooler running |
Dimensions | 20 x 14 x 8" (50 x 36 x 20 cm) |
Weight | Aproximately 26.5 lbs (12 kg) |
Click on a category to view a selection of compatible accessories with the Seitron S9000 Industrial Emissions Analyzer with 12" probe, O2/high range CO.
O2 | 0 to 25% volume |
High Range CO Sensor | 0 to 100,000 ppm |
Autozero | Automatic autozero cycle with gas sampling probe in stack |
Fuel Type | 12 preprogrammed and 16 additional programmable by the user |
Temperature | Working: 23 to 113°F (-5 to 45°C) Storage: -4 to 122°F (-20 to 50°C) |
Probe | 12" (300 mm) probe, 1112°F (600°C) maximum, with 10' (3 m) |
Cooler Sample Treatment | Drying system: Rapid water condensation using cyclone system Type: Peltier cell Set point temperature cooler: 41°F (5°C) Maximum tempersture deviation from set point: 50°F (10°C) from set point Condensate emptying pump: Peristaltic hose 38 ml/minute Peristaltic duty cycle pump: 30 seconds On to 30 seconds Off Warm-up time: Aproximately 15 to 20 minutes Operating temperature: 23 to 113°F (-5 to 45°C) |
Anti-Condensation Trap | Type: Integrated Condensate emptying pump: Peristaltic hose 38 ml/minute Operating temperature: 23 to 113°F (-5 to 45°C) |
Printer | Integrated, thermal, with easy paper loading and paper level indicator Power supply: Analyzer batteries Battery life: With fully charged batteries up to 40 analysis reports |
Internal Data Memory | 16,000 complete data analysis, time and customer's name can be stored |
In-Line Filter | With replaceable cartridge, 99% efficiency with 20 μm particles |
Pump | Vacuum: 2 l/minute flow rate in the stack up to 120 in H2O (300 hPa) head Capacity: Internal sensor measuring pump flow rate |
Humidity Limit | 20 to 80% RH |
Self Diagnostics | Check all functions and internal sensors with status indication |
Temperature Measurement | TcK double input with mini connector (ASTM E 1684-96) for temperature Differential measurement (supply and return) |
Ambient Temperature Measurement | Via internal sensor or T2 TcK input with remote sensor |
Autozero | Automatic autozero cycle with gas sampling probe in stack |
Protection Level | IP21 |
Connectivity | Communication port: Type B USB connector Bluetooth: Communication distance: <328.08' (<100 m), open field |
Display | Backlit TFT graphical colour display 4.3" (10.92 cm) 480 x 272 pixels |
Power | Supply: Li-ion battery pack with internal protection circuit, rechargeable Battery charge: Eight hours from 0 to 90% Charging time: 10 hours of continuous operation (except printer) Instrument battery life: Two hours with cooler running |
Dimensions | 20 x 14 x 8" (50 x 36 x 20 cm) |
Weight | Aproximately 26.5 lbs (12 kg) |
Click on a category to view a selection of compatible accessories with the Seitron S9000 Industrial Emissions Analyzer with 12" probe, O2/high range CO.