SHIMPO PM-DCA-00AC0 Panel Meter, DC Amp Input, Analog Signal Output

Model: PM-DCA-00AC0

SHIMPO PM-DCA-00AC0 Panel Meter, DC Amp Input, Analog Signal Output

Model: PM-DCA-00AC0

This panel meter can be set to one of 4 input ranges from ±2.0000 mA with 0.1 µA resolution to ±5.000 A with 1 mA resolution. It comes standard with an isolated excitation output to power transducers, removing the need for an additional power supply. The PM-DCA-00AC0 has an analog output of 4-20 mA, 0-20 mA 0-10 V, and -10 to +10 V.

This panel meter can be set to one of 4 input ranges from ±2.0000 mA with 0.1 µA resolution to ±5.000 A with 1 mA resolution. It comes standard with an isolated excitation output to power transducers, removing the need for an additional power supply. The PM-DCA-00AC0 has an analog output of 4-20 mA, 0-20 mA 0-10 V, and -10 to +10 V.

Sale Price $364.50 USD
Regular Price $405.00 USD
Availability 2 to 3 Weeks
Quantity

Traceable In-House Calibration Certificate for your PM-DCA-00AC0 Panel Meter

Traceable In-House Calibration Certificate for your PM-DCA-00AC0 Panel Meter

SHIMPO PM-DCA-00AC0 Offers

The PM-DCA-00AC0 is ideal for indicating current or voltage signals in applications involving temperature, pressure, level, flow rate, speed, humidity, level, distance and many more. Used to detect DC power output from solar cells, power supplies, batteries as well as current consumption of DC powered motors and similar devices.

Features

  • Bright, red 5 digit LED display scalable to ±99,999 with adjustable decimal point
  • Universal power range of 85-264 V ac / 90-300 V dc or 10-48 V dc / 12-32 V ac power eliminates need to purchase country specific models
  • Programmable scaling provides flexibility to set up and monitor virtually any process in the desired engineering units
  • Variety of output and communication options:
    • Choice of 2 relays or 2 solid state relays
    • Analog signal option provides: 4-20 mA, 0-20 mA, 0-10 V or -10 V to +10 V outputs
    • Serial data communication of either USB, RS485 or RS232
  • Accuracy of ±0.01% of full scale ±2 counts (LSD)
  • Isolated transducer power output of 5, 10 or 24 V dc, eliminates need for an additional power supply reducing installation costs
  • Digital filtering is menu-selectable for electrically noisy environments
  • Peak and valley values are automatically captured and may be displayed via a pushbutton, control signal input, or be transmitted as serial data if a communication option was ordered
  • High read rates at up to 60 or 50 conversions per second
  • When panel mounted, NEMA 4X (IP65) front cover protection keeps fluids out; enables installation in environments exposed to wash-downs

Applications

  • Detect DC power output
  • Process automation
  • Control
  • Peak or valley capture
  • On/off setpoint alarm

SHIMPO PM-DCA-00AC0 Specifications

Input Signal Ranges (Jumper Selectable) ±2.0000 mA, ±20.000 mA, ±200.00 mA, ±5.000 A
Display Range -99999 to 99999
Scaling Function 5 digits with decimal point adjustment
Accuracy @ 77°F (25°C) ±0.01% of FS ±2 Counts; 5A Range ±10 mA; 300 V & 600 V = ±0.4 V
Display Update Time 3.5/s at 60 Hz, 3/s at 50 Hz
Relay Output (Optional) Mechanical Relays: 8 A @ 250 V AC or 24 V dc; SSR: 120 mA @ 140 V AC or 180 V dc
Analog Signal Output (Optional) Jumper Selectable: 4-20 mA, 0-20 mA, 0-10 V, -10 V to 10 V
Communication: (Optional) RS-232, RS-485, USB
Power Requirement 85-264 V AC / 95-300 V DC; Optional 10-48 V DC / 12-34 V AC
Sensor Excitation (Isolated) 5 Vdc ±5%, 100 mA; 10 V DC ±5%, 120 mA; or 24 V DC ±5%, 50 mA
Click here for complete specifications on the SHIMPO PM-DCA-00AC0

What's included with the SHIMPO PM-DCA-00AC0

  • SHIMPO PM-DCA-00AC0 Panel Meter, DC Amp Input, Analog Signal Output

Ask a question about SHIMPO PM-DCA-00AC0 Panel Meter, DC Amp Input, Analog Signal Output

Customer Reviews for the SHIMPO PM-DCA-00AC0

SHIMPO PM-DCA-00AC0 Offers

The PM-DCA-00AC0 is ideal for indicating current or voltage signals in applications involving temperature, pressure, level, flow rate, speed, humidity, level, distance and many more. Used to detect DC power output from solar cells, power supplies, batteries as well as current consumption of DC powered motors and similar devices.

Features

  • Bright, red 5 digit LED display scalable to ±99,999 with adjustable decimal point
  • Universal power range of 85-264 V ac / 90-300 V dc or 10-48 V dc / 12-32 V ac power eliminates need to purchase country specific models
  • Programmable scaling provides flexibility to set up and monitor virtually any process in the desired engineering units
  • Variety of output and communication options:
    • Choice of 2 relays or 2 solid state relays
    • Analog signal option provides: 4-20 mA, 0-20 mA, 0-10 V or -10 V to +10 V outputs
    • Serial data communication of either USB, RS485 or RS232
  • Accuracy of ±0.01% of full scale ±2 counts (LSD)
  • Isolated transducer power output of 5, 10 or 24 V dc, eliminates need for an additional power supply reducing installation costs
  • Digital filtering is menu-selectable for electrically noisy environments
  • Peak and valley values are automatically captured and may be displayed via a pushbutton, control signal input, or be transmitted as serial data if a communication option was ordered
  • High read rates at up to 60 or 50 conversions per second
  • When panel mounted, NEMA 4X (IP65) front cover protection keeps fluids out; enables installation in environments exposed to wash-downs

Applications

  • Detect DC power output
  • Process automation
  • Control
  • Peak or valley capture
  • On/off setpoint alarm

SHIMPO PM-DCA-00AC0 Specifications

Input Signal Ranges (Jumper Selectable) ±2.0000 mA, ±20.000 mA, ±200.00 mA, ±5.000 A
Display Range -99999 to 99999
Scaling Function 5 digits with decimal point adjustment
Accuracy @ 77°F (25°C) ±0.01% of FS ±2 Counts; 5A Range ±10 mA; 300 V & 600 V = ±0.4 V
Display Update Time 3.5/s at 60 Hz, 3/s at 50 Hz
Relay Output (Optional) Mechanical Relays: 8 A @ 250 V AC or 24 V dc; SSR: 120 mA @ 140 V AC or 180 V dc
Analog Signal Output (Optional) Jumper Selectable: 4-20 mA, 0-20 mA, 0-10 V, -10 V to 10 V
Communication: (Optional) RS-232, RS-485, USB
Power Requirement 85-264 V AC / 95-300 V DC; Optional 10-48 V DC / 12-34 V AC
Sensor Excitation (Isolated) 5 Vdc ±5%, 100 mA; 10 V DC ±5%, 120 mA; or 24 V DC ±5%, 50 mA
Click here for complete specifications on the SHIMPO PM-DCA-00AC0

What's included with the SHIMPO PM-DCA-00AC0

  • SHIMPO PM-DCA-00AC0 Panel Meter, DC Amp Input, Analog Signal Output

Ask a question about SHIMPO PM-DCA-00AC0 Panel Meter, DC Amp Input, Analog Signal Output

Customer Reviews for the SHIMPO PM-DCA-00AC0

More SHIMPO Products