This panel meter can be set to one of 4 input ranges from ±2.0000 mA with 0.1 µA resolution to ±5.000 A with 1 mA resolution. It comes standard with an isolated excitation output to power transducers, removing the need for an additional power supply. The PM-DCA-0S0C0 has a SSR output of two 120 mA solid state relays.
This panel meter can be set to one of 4 input ranges from ±2.0000 mA with 0.1 µA resolution to ±5.000 A with 1 mA resolution. It comes standard with an isolated excitation output to power transducers, removing the need for an additional power supply. The PM-DCA-0S0C0 has a SSR output of two 120 mA solid state relays.
The PM-DCA-0S0C0 is ideal for indicating current or voltage signals in applications involving temperature, pressure, level, flow rate, speed, humidity, level, distance and many more. Used to detect DC power output from solar cells, power supplies, batteries as well as current consumption of DC powered motors and similar devices.
Features
Applications
Input Signal Ranges (Jumper Selectable) | ±2.0000 mA, ±20.000 mA, ±200.00 mA, ±5.000 A |
Display Range | -99999 to 99999 |
Scaling Function | 5 digits with decimal point adjustment |
Accuracy @ 77°F (25°C) | ±0.01% of FS ±2 Counts; 5A Range ±10 mA; 300 V & 600 V = ±0.4 V |
Display Update Time | 3.5/s at 60 Hz, 3/s at 50 Hz |
Relay Output (Optional) | Mechanical Relays: 8 A @ 250 V AC or 24 V dc; SSR: 120 mA @ 140 V AC or 180 V dc |
Analog Signal Output (Optional) | Jumper Selectable: 4-20 mA, 0-20 mA, 0-10 V, -10 V to 10 V |
Communication: (Optional) | RS-232, RS-485, USB |
Power Requirement | 85-264 V AC / 95-300 V DC; Optional 10-48 V DC / 12-34 V AC |
Sensor Excitation (Isolated) | 5 Vdc ±5%, 100 mA; 10 V DC ±5%, 120 mA; or 24 V DC ±5%, 50 mA |
Input Signal Ranges (Jumper Selectable) | ±2.0000 mA, ±20.000 mA, ±200.00 mA, ±5.000 A |
Display Range | -99999 to 99999 |
Scaling Function | 5 digits with decimal point adjustment |
Accuracy @ 77°F (25°C) | ±0.01% of FS ±2 Counts; 5A Range ±10 mA; 300 V & 600 V = ±0.4 V |
Display Update Time | 3.5/s at 60 Hz, 3/s at 50 Hz |
Relay Output (Optional) | Mechanical Relays: 8 A @ 250 V AC or 24 V dc; SSR: 120 mA @ 140 V AC or 180 V dc |
Analog Signal Output (Optional) | Jumper Selectable: 4-20 mA, 0-20 mA, 0-10 V, -10 V to 10 V |
Communication: (Optional) | RS-232, RS-485, USB |
Power Requirement | 85-264 V AC / 95-300 V DC; Optional 10-48 V DC / 12-34 V AC |
Sensor Excitation (Isolated) | 5 Vdc ±5%, 100 mA; 10 V DC ±5%, 120 mA; or 24 V DC ±5%, 50 mA |